Volumetric Postcontrast T1 Turbo Spin-Echo vs Gradient-Recalled Echo MR Sequences for Detecting Brain Metastases: A Systematic Review and Meta-Analysis.

Anass Benomar, Sukhmanjit S Ghumman, Youcef Ouahdi, Sherief Ghozy, Hany Soliman, Kang Liang Zeng, Chia-Lin Tseng, Jay Detsky, Hanbo Chen, Deepak Dinakaran, Qing Fu, Sean Symons, Arjun Sahgal, Chris Heyn, Pejman Jabehdar Maralani
{"title":"Volumetric Postcontrast T1 Turbo Spin-Echo vs Gradient-Recalled Echo MR Sequences for Detecting Brain Metastases: A Systematic Review and Meta-Analysis.","authors":"Anass Benomar, Sukhmanjit S Ghumman, Youcef Ouahdi, Sherief Ghozy, Hany Soliman, Kang Liang Zeng, Chia-Lin Tseng, Jay Detsky, Hanbo Chen, Deepak Dinakaran, Qing Fu, Sean Symons, Arjun Sahgal, Chris Heyn, Pejman Jabehdar Maralani","doi":"10.3174/ajnr.A9294","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Contrast-enhanced 3D T1-weighted MRI is the imaging reference for detection and follow-up of brain metastases. Volumetric GRE-based sequences, such as MPRAGE, are widely used but remain prone to susceptibility and lower lesion conspicuity. 3D black-blood TSE-based sequences, such as sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE), have been increasingly embedded into routine workflow and are thought to improve lesion detection in part through vessel signal suppression.</p><p><strong>Purpose: </strong>We aimed to investigate the comparative diagnostic performance of 3D T1 TSE vs GRE sequences for the detection of brain metastases.</p><p><strong>Data sources: </strong>Studies comparing the diagnostic performance of postcontrast 3D T1 TSE and GRE sequences in adults with brain metastases were searched on MEDLINE, EMBASE, Cochrane Central, Google Scholar, and PROSPERO, from inception through April 2025.</p><p><strong>Study selection: </strong>Fifteen studies encompassing 544 patients with 4338 metastases were included.</p><p><strong>Data analysis: </strong>Data on diagnostic accuracy parameters, image quality, and interrater agreement were extracted. Random-effects models were applied to compute pooled sensitivity and comparative OR for lesion detection. Risk of bias was assessed using QUADAS-2 and QUADAS-C tools.</p><p><strong>Data synthesis: </strong>Pooled sensitivities for detection of brain metastases were 97.4% (95% CI, 93.2%-99.0%) for TSE- and 76.1% (95% CI, 69.3-81.9) for GRE-based sequences, with a comparative OR of 12.0 (95% CI, 5.45-26.6; <i>P</i> < .0001). Detectability of small lesions (<5 mm) was significantly better on TSE (96.1%; 95% CI, 87.7-98.8) than GRE (58.4%; 95% CI, 47.9-68.2), although both techniques performed comparably for larger (≥5 mm) lesions (98.2% for TSE, 94.4% for GRE). OR estimates were 17.2 (95% CI, 4.50-66.1) for small and 2.81 (95% CI, 0.92-8.56) for large lesions. Contrast-to-noise ratio and interrater agreements were slightly higher on TSE than GRE. False-positives (FPs) were more common with TSE, mostly related to incomplete vessel suppression (49 FP counts in TSE, 35 in GRE).</p><p><strong>Limitations: </strong>Our meta-analysis is limited by high heterogeneity, case-only studies, possible small-study effects, and high risk of bias for the reference standard domain.</p><p><strong>Conclusions: </strong>Postcontrast 3D T1 TSE sequences provide higher sensitivity and improved lesion conspicuity compared with GRE sequences, particularly for small metastases, although at the cost of slightly higher FPs.</p>","PeriodicalId":93863,"journal":{"name":"AJNR. American journal of neuroradiology","volume":" ","pages":"2572-2579"},"PeriodicalIF":0.0000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13629716/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AJNR. American journal of neuroradiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3174/ajnr.A9294","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Contrast-enhanced 3D T1-weighted MRI is the imaging reference for detection and follow-up of brain metastases. Volumetric GRE-based sequences, such as MPRAGE, are widely used but remain prone to susceptibility and lower lesion conspicuity. 3D black-blood TSE-based sequences, such as sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE), have been increasingly embedded into routine workflow and are thought to improve lesion detection in part through vessel signal suppression.

Purpose: We aimed to investigate the comparative diagnostic performance of 3D T1 TSE vs GRE sequences for the detection of brain metastases.

Data sources: Studies comparing the diagnostic performance of postcontrast 3D T1 TSE and GRE sequences in adults with brain metastases were searched on MEDLINE, EMBASE, Cochrane Central, Google Scholar, and PROSPERO, from inception through April 2025.

Study selection: Fifteen studies encompassing 544 patients with 4338 metastases were included.

Data analysis: Data on diagnostic accuracy parameters, image quality, and interrater agreement were extracted. Random-effects models were applied to compute pooled sensitivity and comparative OR for lesion detection. Risk of bias was assessed using QUADAS-2 and QUADAS-C tools.

Data synthesis: Pooled sensitivities for detection of brain metastases were 97.4% (95% CI, 93.2%-99.0%) for TSE- and 76.1% (95% CI, 69.3-81.9) for GRE-based sequences, with a comparative OR of 12.0 (95% CI, 5.45-26.6; P < .0001). Detectability of small lesions (<5 mm) was significantly better on TSE (96.1%; 95% CI, 87.7-98.8) than GRE (58.4%; 95% CI, 47.9-68.2), although both techniques performed comparably for larger (≥5 mm) lesions (98.2% for TSE, 94.4% for GRE). OR estimates were 17.2 (95% CI, 4.50-66.1) for small and 2.81 (95% CI, 0.92-8.56) for large lesions. Contrast-to-noise ratio and interrater agreements were slightly higher on TSE than GRE. False-positives (FPs) were more common with TSE, mostly related to incomplete vessel suppression (49 FP counts in TSE, 35 in GRE).

Limitations: Our meta-analysis is limited by high heterogeneity, case-only studies, possible small-study effects, and high risk of bias for the reference standard domain.

Conclusions: Postcontrast 3D T1 TSE sequences provide higher sensitivity and improved lesion conspicuity compared with GRE sequences, particularly for small metastases, although at the cost of slightly higher FPs.

体积成像后T1 Turbo自旋回声与梯度回忆回声MR序列检测脑转移:系统回顾和荟萃分析。
背景:增强3D t1加权MRI是脑转移灶检测及随访的影像学参考。以体积为基础的序列,如MPRAGE,被广泛使用,但仍然容易易感性和较低的病变显著性。基于se的3D黑血序列,例如使用不同翻转角度进化(SPACE)的应用优化对比采样完美,已经越来越多地嵌入到常规工作流程中,并且被认为可以通过血管信号抑制来提高病变检测。目的:我们旨在研究3D T1 TSE序列与GRE序列在脑转移检测中的比较诊断性能。数据来源:在MEDLINE、EMBASE、Cochrane Central、谷歌Scholar和PROSPERO上检索了对比3D T1 SE和GRE序列对成人脑转移诊断性能的研究,从成立到2025年4月。研究选择:纳入15项研究,共544例患者,4338例转移灶。数据分析:提取诊断准确性参数、图像质量和评分者间一致性的数据。随机效应模型用于计算病变检测的集合灵敏度和比较OR。使用QUADAS-2和QUADAS-C工具评估偏倚风险。数据综合:TSE检测脑转移的总敏感性为97.4% (95%CI, 93.2%-99.0%),而基于grei的序列检测脑转移的总敏感性为76.1% (95%CI, 69.3-81.9),比较OR为12.0 (95%CI, 5.45-26.6, P)局限性:我们的荟萃分析受到高度异质性、病例研究、可能的小研究效应和参考标准域的高偏倚风险的限制。结论:与GRE序列相比,对比后3D T1 TSE序列提供了更高的敏感性和更好的病变显著性,特别是对于小转移,尽管以更高的假阳性为代价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书