Mechanical Analysis of Needles Used in Ultrasound-Guided Musculoskeletal Interventions.

IF 2.8 4区 医学 Q3 PHYSIOLOGY
Physiological research Pub Date : 2026-03-13
T Novotny, D Hadraba, K Mezian, L Özçakar
{"title":"Mechanical Analysis of Needles Used in Ultrasound-Guided Musculoskeletal Interventions.","authors":"T Novotny, D Hadraba, K Mezian, L Özçakar","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We performed a mechanical analysis of the commonly used needles for ultrasound-guided interventions in the musculoskeletal system. Specifically, focusing on the ability to absorb potential physical loads and the degree of deformation during the procedure, the needle gauge best suited for those procedures is evaluated. A customized tensile-compression device was used for an experimental buckling strength test on three commonly used needle types with specific gauge sizes. The loss of structural integrity, loss of needle stability, and buckling load were modeled also theoretically using finite element analysis software. Theoretical software needle buckling analysis detected the load for the first buckling mode of the needle, when the highest value was reached for the G20 needle with the load 18.8 N. The load for G21 needle was 9.7 N and for G23 8 N. Experimental data with customized tensile-compression device aligned theoretical data when the highest value was reached for the G20 needle with the load 19.7±1.9 N. The load for G21 needle was 10.6+/-2.7 N and for G23 7.9+/-0.7 N. Theoretical and practical experiments have shown that the standard G20 needle model exhibits the highest mechanical tolerance for potential interventions in the musculoskeletal system. Key words Interventional ultrasound \" Needle \" Buckling strength.</p>","PeriodicalId":20235,"journal":{"name":"Physiological research","volume":"75 1","pages":"183-186"},"PeriodicalIF":2.8000,"publicationDate":"2026-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13128015/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physiological research","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

We performed a mechanical analysis of the commonly used needles for ultrasound-guided interventions in the musculoskeletal system. Specifically, focusing on the ability to absorb potential physical loads and the degree of deformation during the procedure, the needle gauge best suited for those procedures is evaluated. A customized tensile-compression device was used for an experimental buckling strength test on three commonly used needle types with specific gauge sizes. The loss of structural integrity, loss of needle stability, and buckling load were modeled also theoretically using finite element analysis software. Theoretical software needle buckling analysis detected the load for the first buckling mode of the needle, when the highest value was reached for the G20 needle with the load 18.8 N. The load for G21 needle was 9.7 N and for G23 8 N. Experimental data with customized tensile-compression device aligned theoretical data when the highest value was reached for the G20 needle with the load 19.7±1.9 N. The load for G21 needle was 10.6+/-2.7 N and for G23 7.9+/-0.7 N. Theoretical and practical experiments have shown that the standard G20 needle model exhibits the highest mechanical tolerance for potential interventions in the musculoskeletal system. Key words Interventional ultrasound " Needle " Buckling strength.

超声引导肌肉骨骼干预用针的力学分析。
我们对超声引导下用于肌肉骨骼系统干预的常用针进行了力学分析。具体来说,重点是在手术过程中吸收潜在物理负荷的能力和变形程度,评估最适合这些手术的针规。采用定制的抗拉压缩装置,对三种常用的针型进行了特定规径的屈曲强度试验。利用有限元分析软件对结构完整性损失、针稳定性损失和屈曲载荷进行了理论模拟。理论软件针屈曲分析检测了载荷为针的第一屈曲模态;达到最大值时的20国集团(G20)针G21针负荷18.8 N负荷为9.7 N和G23 8 N .实验数据与定制tensile-compression设备一致的理论数据达到最大值时的20国集团(G20)针负载19.7±1.9 N G21针负载为10.6 + / - -2.7 N和G23 7.9 + / - -0.7 N理论和实践实验表明,标准的20国集团(G20)针模型展品的最高机械公差的潜力肌肉骨骼系统的干预。【关键词】介入超声“针”;屈曲强度;
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Physiological research
Physiological research 医学-生理学
CiteScore
4.00
自引率
4.80%
发文量
108
审稿时长
3 months
期刊介绍: Physiological Research is a peer reviewed Open Access journal that publishes articles on normal and pathological physiology, biochemistry, biophysics, and pharmacology. Authors can submit original, previously unpublished research articles, review articles, rapid or short communications. Instructions for Authors - Respect the instructions carefully when submitting your manuscript. Submitted manuscripts or revised manuscripts that do not follow these Instructions will not be included into the peer-review process. The articles are available in full versions as pdf files beginning with volume 40, 1991. The journal publishes the online Ahead of Print /Pre-Press version of the articles that are searchable in Medline and can be cited.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书