Optimal partitioning and operation of water distribution networks under intermittent conditions: A case study of Modena network

IF 5.3 Q1 WATER RESOURCES
Water science and engineering Pub Date : 2026-03-01 Epub Date: 2025-12-15 DOI:10.1016/j.wse.2025.12.002
Rui Gabriel Souza , Thomaz Anchieta , Gustavo Meirelles , Daniel Barros , Bruno Brentan
{"title":"Optimal partitioning and operation of water distribution networks under intermittent conditions: A case study of Modena network","authors":"Rui Gabriel Souza ,&nbsp;Thomaz Anchieta ,&nbsp;Gustavo Meirelles ,&nbsp;Daniel Barros ,&nbsp;Bruno Brentan","doi":"10.1016/j.wse.2025.12.002","DOIUrl":null,"url":null,"abstract":"<div><div>With over 1.3 billion people worldwide facing irregular water access, efficient water management is a global priority. This study presented a comprehensive approach for optimizing the operation of intermittent water distribution networks through the creation of district metered areas (DMAs). It advanced traditional DMA design by integrating network partitioning with optimized operational schedules, offering a practical framework for managing intermittent water supply systems. The proposed methodology aims to reduce water losses while improving service equity and quality. First, the network is partitioned using the fast-greedy community detection algorithm based on modularity from graph theory, enabling DMAs to operate independently at different times of a day. Flow control valves are installed at DMA entry points, while isolation valves isolate remaining boundary pipes, enhancing operational flexibility. Second, the particle swarm optimization algorithm optimizes the operational schedule of each DMA and determines the optimal start time and water supply duration for each DMA. This step minimizes total daily distributed volume while ensuring adequate service. This approach reduced the daily distributed volume of the Modena network by approximately 720.0 m<sup>3</sup> and significantly decreased the leakage rate from 30.5% to 18.7%, demonstrating its effectiveness.</div></div>","PeriodicalId":23628,"journal":{"name":"Water science and engineering","volume":"19 1","pages":"Pages 120-131"},"PeriodicalIF":5.3000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water science and engineering","FirstCategoryId":"1087","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S167423702500105X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0

Abstract

With over 1.3 billion people worldwide facing irregular water access, efficient water management is a global priority. This study presented a comprehensive approach for optimizing the operation of intermittent water distribution networks through the creation of district metered areas (DMAs). It advanced traditional DMA design by integrating network partitioning with optimized operational schedules, offering a practical framework for managing intermittent water supply systems. The proposed methodology aims to reduce water losses while improving service equity and quality. First, the network is partitioned using the fast-greedy community detection algorithm based on modularity from graph theory, enabling DMAs to operate independently at different times of a day. Flow control valves are installed at DMA entry points, while isolation valves isolate remaining boundary pipes, enhancing operational flexibility. Second, the particle swarm optimization algorithm optimizes the operational schedule of each DMA and determines the optimal start time and water supply duration for each DMA. This step minimizes total daily distributed volume while ensuring adequate service. This approach reduced the daily distributed volume of the Modena network by approximately 720.0 m3 and significantly decreased the leakage rate from 30.5% to 18.7%, demonstrating its effectiveness.
间歇条件下配水管网的优化分配与运行——以摩德纳管网为例
全球有超过13亿人面临用水不正常的问题,因此有效的水管理是全球的优先事项。本研究提出了一种通过建立区域计量区域(dma)来优化间歇性配水网络运行的综合方法。它通过将网络分区与优化的运行时间表相结合,改进了传统的DMA设计,为管理间歇性供水系统提供了一个实用的框架。拟议的方法旨在减少水的损失,同时提高服务的公平性和质量。首先,使用基于图论模块化的快速贪婪社区检测算法对网络进行分区,使dma在一天的不同时间独立运行。流量控制阀安装在DMA入口点,而隔离阀隔离剩余的边界管道,提高操作灵活性。其次,粒子群优化算法对各DMA的运行计划进行优化,确定各DMA的最优启动时间和供水持续时间。这一步骤最大限度地减少了每日总分配量,同时确保了足够的服务。该方法使摩德纳管网的日分布容积减少了约720.0 m3,泄漏率从30.5%显著降低到18.7%,表明了其有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.60
自引率
5.00%
发文量
573
审稿时长
50 weeks
期刊介绍: Water Science and Engineering journal is an international, peer-reviewed research publication covering new concepts, theories, methods, and techniques related to water issues. The journal aims to publish research that helps advance the theoretical and practical understanding of water resources, aquatic environment, aquatic ecology, and water engineering, with emphases placed on the innovation and applicability of science and technology in large-scale hydropower project construction, large river and lake regulation, inter-basin water transfer, hydroelectric energy development, ecological restoration, the development of new materials, and sustainable utilization of water resources.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书