Albert Bernet Sánchez , Alba Bellés Bellés , Eric López González , Iván Prats Sanchez , Saray Mormeneo Bayo , María Riesgo Magaña , Mercè García González
{"title":"Comparación entre RT-PCR y TMA en la detección de SARS-CoV-2 y propuesta de algoritmo diagnóstico basado en valores de corte","authors":"Albert Bernet Sánchez , Alba Bellés Bellés , Eric López González , Iván Prats Sanchez , Saray Mormeneo Bayo , María Riesgo Magaña , Mercè García González","doi":"10.1016/j.eimc.2025.503068","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>SARS-CoV-2 caused a pandemic with more than 778 million cases and 7 million deaths. The high diagnostic demand forced laboratories to incorporate new techniques, such as transcription-mediated amplification (TMA). This study compares TMA with RT-PCR in routine clinical samples and evaluates the relationship between relative light units (RLU) and RT-PCR results to define possible cut-off ranges.</div></div><div><h3>Methods</h3><div>A prospective study was carried out over one year in the microbiology laboratory of Hospital Universitari Arnau de Vilanova de Lleida. All samples for SARS-CoV-2 were processed using TMA (Aptima® Hologic), and a portion was analyzed in parallel with RT-PCR (LightMix®, GeneXpert®, or Cobas®). Concordance between techniques, sensitivity, and specificity were calculated. RT-PCR was considered the reference technique.</div></div><div><h3>Results</h3><div>A total of 15,156 samples were analyzed with both techniques. Concordance was substantial (κ<!--> <!-->=<!--> <!-->0.692), with a sensitivity of 97.89% and a specificity of 64.74%. Of the results, 11.28% corresponded to false positives and 8.44% to false negatives for TMA. RLU values between 350 and 559, considered negative by the TMA system, were positive by RT-PCR in 20.56%. In intermediate RLU values (560-899), the probability of having a negative RT-PCR was around 50%, dropping to 3.78% for values between 1000 and 1099.</div></div><div><h3>Conclusions</h3><div>These results support the use of TMA as a screening method, provided the positivity threshold is lowered to 350 RLU and positive cases are confirmed by RT-PCR.</div></div>","PeriodicalId":11608,"journal":{"name":"Enfermedades infecciosas y microbiologia clinica","volume":"44 3","pages":"Article 503068"},"PeriodicalIF":2.2000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Enfermedades infecciosas y microbiologia clinica","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0213005X25002824","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
SARS-CoV-2 caused a pandemic with more than 778 million cases and 7 million deaths. The high diagnostic demand forced laboratories to incorporate new techniques, such as transcription-mediated amplification (TMA). This study compares TMA with RT-PCR in routine clinical samples and evaluates the relationship between relative light units (RLU) and RT-PCR results to define possible cut-off ranges.
Methods
A prospective study was carried out over one year in the microbiology laboratory of Hospital Universitari Arnau de Vilanova de Lleida. All samples for SARS-CoV-2 were processed using TMA (Aptima® Hologic), and a portion was analyzed in parallel with RT-PCR (LightMix®, GeneXpert®, or Cobas®). Concordance between techniques, sensitivity, and specificity were calculated. RT-PCR was considered the reference technique.
Results
A total of 15,156 samples were analyzed with both techniques. Concordance was substantial (κ = 0.692), with a sensitivity of 97.89% and a specificity of 64.74%. Of the results, 11.28% corresponded to false positives and 8.44% to false negatives for TMA. RLU values between 350 and 559, considered negative by the TMA system, were positive by RT-PCR in 20.56%. In intermediate RLU values (560-899), the probability of having a negative RT-PCR was around 50%, dropping to 3.78% for values between 1000 and 1099.
Conclusions
These results support the use of TMA as a screening method, provided the positivity threshold is lowered to 350 RLU and positive cases are confirmed by RT-PCR.
期刊介绍:
Hoy está universalmente reconocida la renovada y creciente importancia de la patología infecciosa: aparición de nuevos agentes patógenos, de cepas resistentes, de procesos con expresión clínica hasta ahora desconocida, de cuadros de una gran complejidad. Paralelamente, la Microbiología y la Infectología Clínicas han experimentado un gran desarrollo como respuesta al reto planteado por la actual patología infecciosa. Enfermedades Infecciosas y Microbiología Clínica es la Publicación Oficial de la Sociedad Española SEIMC. Cumple con la garantía científica de esta Sociedad, la doble función de difundir trabajos de investigación, tanto clínicos como microbiológicos, referidos a la patología infecciosa, y contribuye a la formación continuada de los interesados en aquella patología mediante artículos orientados a ese fin y elaborados por autores de la mayor calificación invitados por la revista.