Shengqi Zhang , Wanchun Hu , Guangdi Liu , Liang Pu
{"title":"Design method and parameters optimization of finned-tube latent thermal energy storage for heat pump applications","authors":"Shengqi Zhang , Wanchun Hu , Guangdi Liu , Liang Pu","doi":"10.1016/j.ijrefrig.2026.02.025","DOIUrl":null,"url":null,"abstract":"<div><div>This study employs a finned-tube heat exchanger as the heat-exchange core and modified Sodium acetate trihydrate (SAT) as the storage medium to design a 6.0 kWh finned-tube latent thermal energy storage (FT-LTES) unit and investigate performance enhancement via geometric optimization. The modified SAT was subjected to 2000 thermal cycles. Compared with the initial state, the latent heat decreased by 7.0%, while the degree of supercooling increased by 9.2 °C. A 3D transient computational model, integrating shell conduction theory with phase change dynamics, was developed to systematically evaluate five geometric parameters: fin thickness, fin spacing, tube diameter, horizontal tube spacing and vertical tube spacing. The discharging performance was evaluated based on the key metrics: effective discharging time, average discharging power and effective water supply volume. The results reveal that, within the studied parameter range, the effective discharging capacity of the FT-LTES module increases with greater fin thickness, smaller fin spacing, and reduced tube spacing, while exhibiting a non-monotonic relationship with tube diameter, initially increasing and then decreasing. An optimized structure for the FT-LTES unit was identified, with fin thickness, fin spacing, horizontal tube spacing, vertical tube spacing, and tube diameter of 0.2 mm, 1.9 mm, 12.0 mm 16.0 mm and 25.4 mm, respectively. Multi-cycle thermal storage and release tests on the optimized structure demonstrated 128.0% improvement in effective water supply volume compared to the original LTES unit.</div></div>","PeriodicalId":14274,"journal":{"name":"International Journal of Refrigeration-revue Internationale Du Froid","volume":"186 ","pages":"Article 106882"},"PeriodicalIF":4.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Refrigeration-revue Internationale Du Froid","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0140700726000769","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/23 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
引用次数: 0
Abstract
This study employs a finned-tube heat exchanger as the heat-exchange core and modified Sodium acetate trihydrate (SAT) as the storage medium to design a 6.0 kWh finned-tube latent thermal energy storage (FT-LTES) unit and investigate performance enhancement via geometric optimization. The modified SAT was subjected to 2000 thermal cycles. Compared with the initial state, the latent heat decreased by 7.0%, while the degree of supercooling increased by 9.2 °C. A 3D transient computational model, integrating shell conduction theory with phase change dynamics, was developed to systematically evaluate five geometric parameters: fin thickness, fin spacing, tube diameter, horizontal tube spacing and vertical tube spacing. The discharging performance was evaluated based on the key metrics: effective discharging time, average discharging power and effective water supply volume. The results reveal that, within the studied parameter range, the effective discharging capacity of the FT-LTES module increases with greater fin thickness, smaller fin spacing, and reduced tube spacing, while exhibiting a non-monotonic relationship with tube diameter, initially increasing and then decreasing. An optimized structure for the FT-LTES unit was identified, with fin thickness, fin spacing, horizontal tube spacing, vertical tube spacing, and tube diameter of 0.2 mm, 1.9 mm, 12.0 mm 16.0 mm and 25.4 mm, respectively. Multi-cycle thermal storage and release tests on the optimized structure demonstrated 128.0% improvement in effective water supply volume compared to the original LTES unit.
期刊介绍:
The International Journal of Refrigeration is published for the International Institute of Refrigeration (IIR) by Elsevier. It is essential reading for all those wishing to keep abreast of research and industrial news in refrigeration, air conditioning and associated fields. This is particularly important in these times of rapid introduction of alternative refrigerants and the emergence of new technology. The journal has published special issues on alternative refrigerants and novel topics in the field of boiling, condensation, heat pumps, food refrigeration, carbon dioxide, ammonia, hydrocarbons, magnetic refrigeration at room temperature, sorptive cooling, phase change materials and slurries, ejector technology, compressors, and solar cooling.
As well as original research papers the International Journal of Refrigeration also includes review articles, papers presented at IIR conferences, short reports and letters describing preliminary results and experimental details, and letters to the Editor on recent areas of discussion and controversy. Other features include forthcoming events, conference reports and book reviews.
Papers are published in either English or French with the IIR news section in both languages.