Patterns of pathogenic microbial contamination of handwashing sinks change over time following new installations

IF 2.6 Q3 INFECTIOUS DISEASES
Infection Prevention in Practice Pub Date : 2026-06-01 Epub Date: 2026-02-09 DOI:10.1016/j.infpip.2026.100516
I. Nakamura , Y. Miura , T. Shimodaira , A. Okugawa , H. Watanabe
{"title":"Patterns of pathogenic microbial contamination of handwashing sinks change over time following new installations","authors":"I. Nakamura ,&nbsp;Y. Miura ,&nbsp;T. Shimodaira ,&nbsp;A. Okugawa ,&nbsp;H. Watanabe","doi":"10.1016/j.infpip.2026.100516","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Environmental contamination of handwashing sinks and drains can negatively impact hand hygiene practices and facilitate pathogen transmission. This study determined what contaminations occurred after sink and drain installation, when and for how long, as well as differences in contamination patterns depending on the purpose of sink use in a non-outbreak setting.</div></div><div><h3>Methods</h3><div>The study was conducted from November 2022 to October 2023. Two new sinks and drainpipes replaced the existing sinks in a general internal medicine hospital ward staff station for use before and after patient care. A third single sink and drainpipe was installed in the staff break room for non-medical use. Bacterial samples were collected from the water tap, sink basin, drain and drainpipe by swab or sponge on days 1 (installation day) and 3 in week 1, in week 2 and monthly thereafter. The cleaning staff members were responsible for cleaning the sink basins and drains daily with detergent.</div></div><div><h3>Results</h3><div>Within the first week after installation, pathogenic microbial contamination (<em>Pseudomonas aeruginosa</em>, <em>Citrobacter freundii</em> and <em>Stenotrophomonas maltophilia</em>) of drainpipes was observed in both the staff station and the break room. Taps were contaminated 2 weeks after installation at the staff station. The contamination cleared but recurred repeatedly until the 12-month point. Pathogens in drainpipes persisted for longer in the staff station than in the break room.</div></div><div><h3>Conclusion</h3><div>The intermittent microbial contamination patterns of the handwashing sinks changed over time following their installation. Pathogenic microbes persisted, especially in drainpipes and in sinks used for clinical purposes, as opposed to non-clinically used sinks.</div></div>","PeriodicalId":33492,"journal":{"name":"Infection Prevention in Practice","volume":"8 2","pages":"Article 100516"},"PeriodicalIF":2.6000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infection Prevention in Practice","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590088926000107","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/9 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Environmental contamination of handwashing sinks and drains can negatively impact hand hygiene practices and facilitate pathogen transmission. This study determined what contaminations occurred after sink and drain installation, when and for how long, as well as differences in contamination patterns depending on the purpose of sink use in a non-outbreak setting.

Methods

The study was conducted from November 2022 to October 2023. Two new sinks and drainpipes replaced the existing sinks in a general internal medicine hospital ward staff station for use before and after patient care. A third single sink and drainpipe was installed in the staff break room for non-medical use. Bacterial samples were collected from the water tap, sink basin, drain and drainpipe by swab or sponge on days 1 (installation day) and 3 in week 1, in week 2 and monthly thereafter. The cleaning staff members were responsible for cleaning the sink basins and drains daily with detergent.

Results

Within the first week after installation, pathogenic microbial contamination (Pseudomonas aeruginosa, Citrobacter freundii and Stenotrophomonas maltophilia) of drainpipes was observed in both the staff station and the break room. Taps were contaminated 2 weeks after installation at the staff station. The contamination cleared but recurred repeatedly until the 12-month point. Pathogens in drainpipes persisted for longer in the staff station than in the break room.

Conclusion

The intermittent microbial contamination patterns of the handwashing sinks changed over time following their installation. Pathogenic microbes persisted, especially in drainpipes and in sinks used for clinical purposes, as opposed to non-clinically used sinks.
洗手槽的病原微生物污染模式随着新设备的安装而改变
洗手槽和排水沟的环境污染会对手部卫生习惯产生负面影响,并促进病原体传播。本研究确定了水槽和排水管安装后发生的污染,时间和持续时间,以及污染模式的差异,这取决于在非疫情环境中使用水槽的目的。方法研究时间为2022年11月至2023年10月。两个新的水槽和排水管取代了普通内科医院病房工作人员站现有的水槽,供病人护理前后使用。在工作人员休息室安装了第三个单水槽和排水管,供非医疗使用。分别于第1天(安装日)、第1周、第2周及以后每月用棉签或海绵从水龙头、水槽、排水管和排水管处采集细菌样本。清洁人员负责每天用洗涤剂清洁水槽和排水管。结果安装后1周内,工作人员站和休息室均检测到排水管的病原菌污染(铜绿假单胞菌、弗氏柠檬酸杆菌和嗜麦芽窄养单胞菌)。工作人员站的水龙头在安装两星期后受到污染。污染消失了,但直到12个月后才反复出现。排水管里的病原体在员工站比在休息室里存留的时间更长。结论洗手槽的间歇性微生物污染模式随时间的推移而变化。病原微生物持续存在,特别是在排水管和用于临床目的的水槽中,而不是在非临床使用的水槽中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Infection Prevention in Practice
Infection Prevention in Practice Medicine-Public Health, Environmental and Occupational Health
CiteScore
4.80
自引率
0.00%
发文量
58
审稿时长
61 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书