Martina Butori , John Petrovick , Björn Eriksson , Marcus Liljenberg , Marcus Ringström , Patric Jannasch , Pontus Svens , Carina Lagergren , Göran Lindbergh , Rakel Wreland Lindström
{"title":"Intermediate temperature proton exchange membrane fuel cells: a systematic review of recently electrochemically evaluated materials","authors":"Martina Butori , John Petrovick , Björn Eriksson , Marcus Liljenberg , Marcus Ringström , Patric Jannasch , Pontus Svens , Carina Lagergren , Göran Lindbergh , Rakel Wreland Lindström","doi":"10.1016/j.apenergy.2026.127499","DOIUrl":null,"url":null,"abstract":"<div><div>The integration of proton exchange membrane fuel cells (PEMFCs) in heavy-duty vehicles and other demanding applications, such as aviation, would be simplified if the stacks could operate above 100 °C instead of the traditional low temperature (LT, up to 80 °C), thereby allowing a reduction in cooling system in size and power. This review offers a comprehensive compilation of experimental studies reported in the literature on PEMFCs operated in the intermediate temperature (IT)-range, here defined as above 80 °C and up to 120 °C, which represented the targeted upper temperature for PEMFCs. Membranes, electrodes and gas diffusion layers for IT-PEMFCs are discussed. Particular attention is paid to polymers in membranes and catalyst layer ionomers. Results from current state-of-the-art perfluorosulfonic acids and alternatives, including hydrocarbon polymers, are evaluated considering their properties and limitations. Further, system benefits and drawbacks of IT- compared to the traditional LT-operation are discussed, such as the interplay between vapour and oxygen pressure, hydrogen crossover and water management. We report on the lack of consistency between ex-situ and in-situ studies and underline the importance of in-situ tests, proposing guidelines to evaluate novel materials. For IT-operation, the development of stable polymers, which are the weakest components of the PEMFCs, is the most urgent challenge. As degradation happens faster at higher temperatures, further long-term tests are needed above 80 °C and accelerated stress tests should be specifically designed for IT-operation according to the polymer chemistries. We conclude that, compared to LT-, IT-operation requires improved materials and additional research.</div></div>","PeriodicalId":246,"journal":{"name":"Applied Energy","volume":"410 ","pages":"Article 127499"},"PeriodicalIF":12.2000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0306261926001510","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
The integration of proton exchange membrane fuel cells (PEMFCs) in heavy-duty vehicles and other demanding applications, such as aviation, would be simplified if the stacks could operate above 100 °C instead of the traditional low temperature (LT, up to 80 °C), thereby allowing a reduction in cooling system in size and power. This review offers a comprehensive compilation of experimental studies reported in the literature on PEMFCs operated in the intermediate temperature (IT)-range, here defined as above 80 °C and up to 120 °C, which represented the targeted upper temperature for PEMFCs. Membranes, electrodes and gas diffusion layers for IT-PEMFCs are discussed. Particular attention is paid to polymers in membranes and catalyst layer ionomers. Results from current state-of-the-art perfluorosulfonic acids and alternatives, including hydrocarbon polymers, are evaluated considering their properties and limitations. Further, system benefits and drawbacks of IT- compared to the traditional LT-operation are discussed, such as the interplay between vapour and oxygen pressure, hydrogen crossover and water management. We report on the lack of consistency between ex-situ and in-situ studies and underline the importance of in-situ tests, proposing guidelines to evaluate novel materials. For IT-operation, the development of stable polymers, which are the weakest components of the PEMFCs, is the most urgent challenge. As degradation happens faster at higher temperatures, further long-term tests are needed above 80 °C and accelerated stress tests should be specifically designed for IT-operation according to the polymer chemistries. We conclude that, compared to LT-, IT-operation requires improved materials and additional research.
期刊介绍:
Applied Energy serves as a platform for sharing innovations, research, development, and demonstrations in energy conversion, conservation, and sustainable energy systems. The journal covers topics such as optimal energy resource use, environmental pollutant mitigation, and energy process analysis. It welcomes original papers, review articles, technical notes, and letters to the editor. Authors are encouraged to submit manuscripts that bridge the gap between research, development, and implementation. The journal addresses a wide spectrum of topics, including fossil and renewable energy technologies, energy economics, and environmental impacts. Applied Energy also explores modeling and forecasting, conservation strategies, and the social and economic implications of energy policies, including climate change mitigation. It is complemented by the open-access journal Advances in Applied Energy.