{"title":"Rapid electrochemical biosensor with enhanced accuracy and repeatability using Pyrene NHS ester modified 3D graphene electrodes","authors":"Sophia Nazir , David Jenkins , Genhua Pan","doi":"10.1016/j.biosx.2026.100757","DOIUrl":null,"url":null,"abstract":"<div><div>A consistent and reproducible chemical modification of the transducer interface is essential to ensure effective immobilization of bioreceptors, thereby improving the sensitivity and reproducibility of biosensors. Although notable progress has been made in fabricating graphene-based biosensors, the effects of surface biofunctionalization on sensing performance remain not fully understood. This study shows that combining three-dimensional (3D) graphene foam electrodes with a straightforward, single-step surface biofunctionalization method is key to enhancing the performance of graphene-based biosensors. Specifically, it presents a single-step approach to functionalize the 3D graphene foam (Gii-Sens) with 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyrene-NHS ester). Electrochemical techniques, including cyclic voltammetry (CV) and differential pulse voltammetry (DPV), confirmed the successful attachment of Pyrene-NHS ester to the graphene foam surface, at levels sufficient to serve as a covalent linker for antibody attachment. The graphene structure was maintained through non-covalent functionalization, and the linker's functionality was verified using the functionalized Gii-Sens electrochemical sensor for detecting Tau-217 peptides. Measurements with the developed electrochemical sensor showed a linear response to Tau-217 peptides within the 1 fM to 1 nM concentration range, with a limit of detection (LoD) of 0.41 fM in both phosphate-buffered saline PBS and serum. The sensor's reproducibility and repeatability were tested using the standard addition method, resulting in a relative standard deviation (RSD) of less than 5%. Specificity was evaluated against Tau-181, Tau-441, amyloid proteins (Aβ<sub>1-40</sub> and Aβ<sub>1-42</sub>), and bovine serum albumin (BSA).</div></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"29 ","pages":"Article 100757"},"PeriodicalIF":10.6100,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590137026000221","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0
Abstract
A consistent and reproducible chemical modification of the transducer interface is essential to ensure effective immobilization of bioreceptors, thereby improving the sensitivity and reproducibility of biosensors. Although notable progress has been made in fabricating graphene-based biosensors, the effects of surface biofunctionalization on sensing performance remain not fully understood. This study shows that combining three-dimensional (3D) graphene foam electrodes with a straightforward, single-step surface biofunctionalization method is key to enhancing the performance of graphene-based biosensors. Specifically, it presents a single-step approach to functionalize the 3D graphene foam (Gii-Sens) with 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyrene-NHS ester). Electrochemical techniques, including cyclic voltammetry (CV) and differential pulse voltammetry (DPV), confirmed the successful attachment of Pyrene-NHS ester to the graphene foam surface, at levels sufficient to serve as a covalent linker for antibody attachment. The graphene structure was maintained through non-covalent functionalization, and the linker's functionality was verified using the functionalized Gii-Sens electrochemical sensor for detecting Tau-217 peptides. Measurements with the developed electrochemical sensor showed a linear response to Tau-217 peptides within the 1 fM to 1 nM concentration range, with a limit of detection (LoD) of 0.41 fM in both phosphate-buffered saline PBS and serum. The sensor's reproducibility and repeatability were tested using the standard addition method, resulting in a relative standard deviation (RSD) of less than 5%. Specificity was evaluated against Tau-181, Tau-441, amyloid proteins (Aβ1-40 and Aβ1-42), and bovine serum albumin (BSA).
期刊介绍:
Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.