{"title":"Rapid electrochemical biosensor with enhanced accuracy and repeatability using Pyrene NHS ester modified 3D graphene electrodes","authors":"Sophia Nazir ,&nbsp;David Jenkins ,&nbsp;Genhua Pan","doi":"10.1016/j.biosx.2026.100757","DOIUrl":null,"url":null,"abstract":"<div><div>A consistent and reproducible chemical modification of the transducer interface is essential to ensure effective immobilization of bioreceptors, thereby improving the sensitivity and reproducibility of biosensors. Although notable progress has been made in fabricating graphene-based biosensors, the effects of surface biofunctionalization on sensing performance remain not fully understood. This study shows that combining three-dimensional (3D) graphene foam electrodes with a straightforward, single-step surface biofunctionalization method is key to enhancing the performance of graphene-based biosensors. Specifically, it presents a single-step approach to functionalize the 3D graphene foam (Gii-Sens) with 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyrene-NHS ester). Electrochemical techniques, including cyclic voltammetry (CV) and differential pulse voltammetry (DPV), confirmed the successful attachment of Pyrene-NHS ester to the graphene foam surface, at levels sufficient to serve as a covalent linker for antibody attachment. The graphene structure was maintained through non-covalent functionalization, and the linker's functionality was verified using the functionalized Gii-Sens electrochemical sensor for detecting Tau-217 peptides. Measurements with the developed electrochemical sensor showed a linear response to Tau-217 peptides within the 1 fM to 1 nM concentration range, with a limit of detection (LoD) of 0.41 fM in both phosphate-buffered saline PBS and serum. The sensor's reproducibility and repeatability were tested using the standard addition method, resulting in a relative standard deviation (RSD) of less than 5%. Specificity was evaluated against Tau-181, Tau-441, amyloid proteins (Aβ<sub>1-40</sub> and Aβ<sub>1-42</sub>), and bovine serum albumin (BSA).</div></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"29 ","pages":"Article 100757"},"PeriodicalIF":10.6100,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590137026000221","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

A consistent and reproducible chemical modification of the transducer interface is essential to ensure effective immobilization of bioreceptors, thereby improving the sensitivity and reproducibility of biosensors. Although notable progress has been made in fabricating graphene-based biosensors, the effects of surface biofunctionalization on sensing performance remain not fully understood. This study shows that combining three-dimensional (3D) graphene foam electrodes with a straightforward, single-step surface biofunctionalization method is key to enhancing the performance of graphene-based biosensors. Specifically, it presents a single-step approach to functionalize the 3D graphene foam (Gii-Sens) with 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyrene-NHS ester). Electrochemical techniques, including cyclic voltammetry (CV) and differential pulse voltammetry (DPV), confirmed the successful attachment of Pyrene-NHS ester to the graphene foam surface, at levels sufficient to serve as a covalent linker for antibody attachment. The graphene structure was maintained through non-covalent functionalization, and the linker's functionality was verified using the functionalized Gii-Sens electrochemical sensor for detecting Tau-217 peptides. Measurements with the developed electrochemical sensor showed a linear response to Tau-217 peptides within the 1 fM to 1 nM concentration range, with a limit of detection (LoD) of 0.41 fM in both phosphate-buffered saline PBS and serum. The sensor's reproducibility and repeatability were tested using the standard addition method, resulting in a relative standard deviation (RSD) of less than 5%. Specificity was evaluated against Tau-181, Tau-441, amyloid proteins (Aβ1-40 and Aβ1-42), and bovine serum albumin (BSA).

Abstract Image

快速电化学生物传感器与提高准确性和可重复性使用芘NHS酯修饰的3D石墨烯电极
换能器界面的一致和可重复的化学修饰对于确保生物受体的有效固定化至关重要,从而提高生物传感器的灵敏度和可重复性。虽然石墨烯基生物传感器的制造已经取得了显著的进展,但表面生物功能化对传感性能的影响仍未完全了解。该研究表明,将三维(3D)石墨烯泡沫电极与简单的单步表面生物功能化方法相结合是提高石墨烯基生物传感器性能的关键。具体来说,它提出了一种单步方法,用1-芘丁酸n -羟基琥珀酰亚胺酯(芘- nhs酯)功能化3D石墨烯泡沫(gi - sens)。包括循环伏安法(CV)和差分脉冲伏安法(DPV)在内的电化学技术证实了pyrenee - nhs酯在石墨烯泡沫表面的成功附着,其水平足以作为抗体附着的共价连接体。通过非共价功能化维持石墨烯结构,并使用功能化的gi - sens电化学传感器检测Tau-217肽,验证了连接体的功能。所开发的电化学传感器对Tau-217肽在1 fM至1 nM浓度范围内呈线性响应,在磷酸盐缓冲盐水PBS和血清中的检测限(LoD)均为0.41 fM。采用标准加法法对传感器的再现性和重复性进行了测试,相对标准偏差(RSD)小于5%。对Tau-181、Tau-441、淀粉样蛋白(a - β1-40和a - β1-42)和牛血清白蛋白(BSA)进行特异性评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biosensors and Bioelectronics: X
Biosensors and Bioelectronics: X Biochemistry, Genetics and Molecular Biology-Biophysics
CiteScore
4.60
自引率
0.00%
发文量
166
审稿时长
54 days
期刊介绍: Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书