Lingling Chen , Yuxin Dong , Ziqian Wang , Chipu Zhang , Zhihao Yang , Pengyue Lai , Zhihao Liu
{"title":"Decoupled model predictive control with SCESO for contact force regulation of a shape-adaptive shield in assistive toileting robots","authors":"Lingling Chen , Yuxin Dong , Ziqian Wang , Chipu Zhang , Zhihao Yang , Pengyue Lai , Zhihao Liu","doi":"10.1016/j.ifacsc.2026.100390","DOIUrl":null,"url":null,"abstract":"<div><div>To overcome the limitations of discomfort and physical constraints in existing wearable nursing devices, this paper proposes a non-wearable shape-adaptive shield integrated with real-time pressure sensing for assistive toileting robots. The shield employs a bionic continuum structure with multiple adjustable spine segments and flexible sensors, enabling safe body conformity and contact force monitoring across diverse body types. To address multi-input multi-output coupling that compromise force control stability, an integral-type state feedback decoupling method is developed to mitigate inter-segment coupling. Furthermore, a novel control strategy integrating State-Compensated Extended State Observer (SCESO) and Model Predictive Control (MPC) is proposed to optimize dynamic force tracking under uncertainties. Simulations and experiments demonstrate that the decoupling-SCESO-MPC framework achieves superior tracking accuracy (average root mean square error of 0.017 N across 10 subjects with diverse body types) and robust performance, thereby providing a practical solution for safe, comfortable, and adaptive human–robot interaction in assistive toileting scenarios.</div></div>","PeriodicalId":29926,"journal":{"name":"IFAC Journal of Systems and Control","volume":"35 ","pages":"Article 100390"},"PeriodicalIF":1.9000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IFAC Journal of Systems and Control","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2468601826000301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
To overcome the limitations of discomfort and physical constraints in existing wearable nursing devices, this paper proposes a non-wearable shape-adaptive shield integrated with real-time pressure sensing for assistive toileting robots. The shield employs a bionic continuum structure with multiple adjustable spine segments and flexible sensors, enabling safe body conformity and contact force monitoring across diverse body types. To address multi-input multi-output coupling that compromise force control stability, an integral-type state feedback decoupling method is developed to mitigate inter-segment coupling. Furthermore, a novel control strategy integrating State-Compensated Extended State Observer (SCESO) and Model Predictive Control (MPC) is proposed to optimize dynamic force tracking under uncertainties. Simulations and experiments demonstrate that the decoupling-SCESO-MPC framework achieves superior tracking accuracy (average root mean square error of 0.017 N across 10 subjects with diverse body types) and robust performance, thereby providing a practical solution for safe, comfortable, and adaptive human–robot interaction in assistive toileting scenarios.