Finger-actuated microfluidic chip for chlorine and copper ion detection in water

IF 2.9 4区 工程技术 Q2 INSTRUMENTS & INSTRUMENTATION
Ming-Zhang Jiang, Yu-Si Wang, Ju-Nan Kuo
{"title":"Finger-actuated microfluidic chip for chlorine and copper ion detection in water","authors":"Ming-Zhang Jiang,&nbsp;Yu-Si Wang,&nbsp;Ju-Nan Kuo","doi":"10.1007/s10404-026-02887-y","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>Ensuring a safe and clean water supply is essential for public health and environmental sustainability. The presence of contaminants, such as residual chlorine and copper ions, can pose significant health risks. Thus, developing rapid and reliable water quality monitoring techniques is essential. Conventional laboratory-based methods are highly accurate but depend on expensive instrumentation and trained personnel, making them unsuitable for on-site applications. To address this problem, this study presents a finger-actuated microfluidic chip integrated with a smartphone-based colorimetric analysis system for the rapid on-site detection of residual chlorine and copper ions in water. The PDMS/glass hybrid device is fully power-independent and utilizes only manual finger pressure to propel the samples and reagents through the microchannel network. The device incorporates a square-wave microchannel design to enhance passive fluid mixing within the confined microscale environment. The simulation and experimental results demonstrate an excellent agreement, with mixing efficiencies of 98.5% and 95.5%, respectively. For quantitative detection, a 3D-printed cassette is combined with a custom-developed smartphone application to capture and process RGB color data in real-time. The calibration curves constructed using residual chlorine (0.6–6 ppm) and copper ion (0.25–2 ppm) control samples exhibit excellent linearity, with coefficients of determination (R²) of 0.9902 and 0.9867, respectively. Moreover, verification trials performed using real environmental water samples reveal relative errors lower than 10.0% for residual chlorine and 9.6% for copper ions, confirming both the reliability and practical applicability of the proposed system. Overall, the portable, power-free microfluidic platform provides a cost-efficient and user-friendly tool for decentralized water quality monitoring, offering a practical solution for enhancing public health protection in regions lacking access to conventional laboratory infrastructure.</p>\n </div>","PeriodicalId":706,"journal":{"name":"Microfluidics and Nanofluidics","volume":"30 4","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2026-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microfluidics and Nanofluidics","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10404-026-02887-y","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

Ensuring a safe and clean water supply is essential for public health and environmental sustainability. The presence of contaminants, such as residual chlorine and copper ions, can pose significant health risks. Thus, developing rapid and reliable water quality monitoring techniques is essential. Conventional laboratory-based methods are highly accurate but depend on expensive instrumentation and trained personnel, making them unsuitable for on-site applications. To address this problem, this study presents a finger-actuated microfluidic chip integrated with a smartphone-based colorimetric analysis system for the rapid on-site detection of residual chlorine and copper ions in water. The PDMS/glass hybrid device is fully power-independent and utilizes only manual finger pressure to propel the samples and reagents through the microchannel network. The device incorporates a square-wave microchannel design to enhance passive fluid mixing within the confined microscale environment. The simulation and experimental results demonstrate an excellent agreement, with mixing efficiencies of 98.5% and 95.5%, respectively. For quantitative detection, a 3D-printed cassette is combined with a custom-developed smartphone application to capture and process RGB color data in real-time. The calibration curves constructed using residual chlorine (0.6–6 ppm) and copper ion (0.25–2 ppm) control samples exhibit excellent linearity, with coefficients of determination (R²) of 0.9902 and 0.9867, respectively. Moreover, verification trials performed using real environmental water samples reveal relative errors lower than 10.0% for residual chlorine and 9.6% for copper ions, confirming both the reliability and practical applicability of the proposed system. Overall, the portable, power-free microfluidic platform provides a cost-efficient and user-friendly tool for decentralized water quality monitoring, offering a practical solution for enhancing public health protection in regions lacking access to conventional laboratory infrastructure.

指控微流控芯片用于水中氯和铜离子的检测
确保安全和清洁的供水对公共健康和环境的可持续性至关重要。残留氯和铜离子等污染物的存在会对健康构成重大威胁。因此,开发快速可靠的水质监测技术至关重要。传统的基于实验室的方法非常准确,但依赖于昂贵的仪器和训练有素的人员,使其不适合现场应用。为了解决这一问题,本研究提出了一种集成智能手机比色分析系统的手指驱动微流控芯片,用于快速现场检测水中的余氯和铜离子。PDMS/玻璃混合装置完全不依赖于电源,仅利用手动手指压力推动样品和试剂通过微通道网络。该装置采用方波微通道设计,以增强在受限微尺度环境中的被动流体混合。仿真结果与实验结果吻合良好,混合效率分别为98.5%和95.5%。对于定量检测,3d打印卡带与定制开发的智能手机应用程序相结合,可以实时捕获和处理RGB颜色数据。以余氯(0.6 ~ 6 ppm)和铜离子(0.25 ~ 2 ppm)为对照样品建立的校准曲线线性良好,决定系数(R²)分别为0.9902和0.9867。此外,使用真实环境水样进行的验证试验表明,余氯的相对误差低于10.0%,铜离子的相对误差低于9.6%,证实了所提出系统的可靠性和实用性。总体而言,便携式无电源微流体平台为分散水质监测提供了一种经济高效且用户友好的工具,为缺乏传统实验室基础设施的地区加强公共卫生保护提供了实用的解决方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Microfluidics and Nanofluidics
Microfluidics and Nanofluidics 工程技术-纳米科技
CiteScore
4.80
自引率
3.60%
发文量
97
审稿时长
2 months
期刊介绍: Microfluidics and Nanofluidics is an international peer-reviewed journal that aims to publish papers in all aspects of microfluidics, nanofluidics and lab-on-a-chip science and technology. The objectives of the journal are to (1) provide an overview of the current state of the research and development in microfluidics, nanofluidics and lab-on-a-chip devices, (2) improve the fundamental understanding of microfluidic and nanofluidic phenomena, and (3) discuss applications of microfluidics, nanofluidics and lab-on-a-chip devices. Topics covered in this journal include: 1.000 Fundamental principles of micro- and nanoscale phenomena like, flow, mass transport and reactions 3.000 Theoretical models and numerical simulation with experimental and/or analytical proof 4.000 Novel measurement & characterization technologies 5.000 Devices (actuators and sensors) 6.000 New unit-operations for dedicated microfluidic platforms 7.000 Lab-on-a-Chip applications 8.000 Microfabrication technologies and materials Please note, Microfluidics and Nanofluidics does not publish manuscripts studying pure microscale heat transfer since there are many journals that cover this field of research (Journal of Heat Transfer, Journal of Heat and Mass Transfer, Journal of Heat and Fluid Flow, etc.).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书