Ex Vivo Evaluation of Intra-Articular Cranial Cruciate Ligament Repair Using an Ultra-High Molecular Weight Polyethylene Graft in the Cats.

IF 1.1 2区 农林科学 Q3 VETERINARY SCIENCES
Parisa Mazdarani, James E Miles
{"title":"Ex Vivo Evaluation of Intra-Articular Cranial Cruciate Ligament Repair Using an Ultra-High Molecular Weight Polyethylene Graft in the Cats.","authors":"Parisa Mazdarani, James E Miles","doi":"10.1055/a-2819-0853","DOIUrl":null,"url":null,"abstract":"<p><p>This aim of this study was to determine feline stifle joint stability and muscle force ratios after cranial cruciate ligament transection and intra-articular reconstruction, and assess the feasibility of this reconstruction in cats.Ten feline hindlimbs were tested in an axial limb press with 30% body weight load. Femoral angles were set to 60 degrees, and stifle and hock angles to 120 degrees. The cranial cruciate ligament was transected, and testing was repeated. Intra-articular reconstruction was performed using a 16-strand ultra-high molecular weight polyethylene graft and four 3 mm interference screws. Friedman's repeated-measures analysis of variance compared angles, forces, and tibial translation.Tibial translation increased significantly after cranial cruciate ligament transection (<i>p</i> = 0.02) but did not differ from intact joints post-reconstruction (<i>p</i> = 0.5). Forces (<i>p</i> = 0.72, <i>p</i> = 0.74) and bone/joint angles (<i>p</i> = 0.12) did not differ across test situations. Mean quadriceps force was twice the gastrocnemius force. Measurement repeatability was good, with a within-subject standard deviation for distance at 0.4 mm and for angles at 0.4 to 1.1 degrees.Limb press positioning was consistent and repeatable, and muscle forces approached <i>in vivo</i> values. Intra-articular reconstruction restored joint stability under static load and appeared feasible for use in cats.</p>","PeriodicalId":51204,"journal":{"name":"Veterinary and Comparative Orthopaedics and Traumatology","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2026-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary and Comparative Orthopaedics and Traumatology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1055/a-2819-0853","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

This aim of this study was to determine feline stifle joint stability and muscle force ratios after cranial cruciate ligament transection and intra-articular reconstruction, and assess the feasibility of this reconstruction in cats.Ten feline hindlimbs were tested in an axial limb press with 30% body weight load. Femoral angles were set to 60 degrees, and stifle and hock angles to 120 degrees. The cranial cruciate ligament was transected, and testing was repeated. Intra-articular reconstruction was performed using a 16-strand ultra-high molecular weight polyethylene graft and four 3 mm interference screws. Friedman's repeated-measures analysis of variance compared angles, forces, and tibial translation.Tibial translation increased significantly after cranial cruciate ligament transection (p = 0.02) but did not differ from intact joints post-reconstruction (p = 0.5). Forces (p = 0.72, p = 0.74) and bone/joint angles (p = 0.12) did not differ across test situations. Mean quadriceps force was twice the gastrocnemius force. Measurement repeatability was good, with a within-subject standard deviation for distance at 0.4 mm and for angles at 0.4 to 1.1 degrees.Limb press positioning was consistent and repeatable, and muscle forces approached in vivo values. Intra-articular reconstruction restored joint stability under static load and appeared feasible for use in cats.

用超高分子量聚乙烯移植修复猫关节内颅交叉韧带的离体评价。
本研究的目的是确定猫在颅十字韧带横断和关节内重建后的膝关节稳定性和肌力比,并评估这种重建在猫身上的可行性。对10只猫后肢进行了30%体重负荷的轴向肢压试验。股骨角设为60度,膝关节和飞节角设为120度。横切颅十字韧带,重复检测。关节内重建采用16股超高分子量聚乙烯移植物和4枚3mm干涉螺钉。弗里德曼的重复测量分析比较了角度、力和胫骨平移。颅骨十字韧带断裂后胫骨平移明显增加(p = 0.02),但与完整关节重建后差异无统计学意义(p = 0.5)。力(p = 0.72, p = 0.74)和骨/关节角度(p = 0.12)在不同的测试情况下没有差异。平均股四头肌力是腓肠肌力的两倍。测量重复性好,距离为0.4 mm,角度为0.4至1.1度,受试者内标准偏差。肢体按压定位一致且可重复,肌肉力量接近体内值。关节内重建恢复了关节在静负荷下的稳定性,在猫身上似乎是可行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.00
自引率
15.40%
发文量
49
审稿时长
18-36 weeks
期刊介绍: Veterinary and Comparative Orthopaedics and Traumatology (VCOT) is the most important single source for clinically relevant information in orthopaedics and neurosurgery available anywhere in the world today. It is unique in that it is truly comparative and there is an unrivalled mix of review articles and basic science amid the information that is immediately clinically relevant in veterinary surgery today.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书