Comparison of the Calibrated Automated Thrombogram Using Standard and Low Plasma Volumes in Dogs.

IF 1 4区 农林科学 Q3 VETERINARY SCIENCES
Veterinary clinical pathology Pub Date : 2026-03-01 Epub Date: 2026-03-07 DOI:10.1111/vcp.70088
Erin M Phillips, Shauna L Blois, Gabrielle Monteith, Anthony C G Abrams-Ogg, R Darren Wood, Benoît Cuq
{"title":"Comparison of the Calibrated Automated Thrombogram Using Standard and Low Plasma Volumes in Dogs.","authors":"Erin M Phillips, Shauna L Blois, Gabrielle Monteith, Anthony C G Abrams-Ogg, R Darren Wood, Benoît Cuq","doi":"10.1111/vcp.70088","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Thrombin generation assessment using calibrated automated thrombography (CAT) requires a standard volume of plasma (80 μL) and reagent (20 μL) run in triplicate. A CAT method using lower plasma and reagent volumes could benefit veterinary patients as it lowers the sampling burden in patients.</p><p><strong>Objectives: </strong>To compare standard CAT methodology to a low plasma and low reagent volume CAT method in dogs.</p><p><strong>Methods: </strong>Platelet-poor plasma samples were obtained by direct jugular venipuncture in dogs with low (n = 10), high (n = 10), and normal (n = 10) thrombin generation potential, recruited from a tertiary referral hospital. Method comparison was performed between standard CAT (80 μL plasma, 20 μL reagent- method 1) and low volume CAT (40 μL plasma, 10 μL reagent- method 2). Lag time (lag time); endogenous thrombin potential (ETP); peak (peak); and time to peak (ttpeak) were assessed on the thrombin generation curves.</p><p><strong>Results: </strong>There was excellent agreement between methods 1 and 2 for all parameters. Lin's concordance coefficients were 0.97, 0.94, 0.96, and 0.96 for lag time, ETP, ttpeak, and peak, respectively. There was a small bias for all parameters (p < 0.05), resulting in a significant change for lag time only. There was a significant predictive linear equation that, when modeled, allowed the conversion of method 2 to method 1 values. The methods had similar variation when measuring TG variables.</p><p><strong>Conclusions: </strong>Based on the results in this small group of dogs, we conclude that low-volume CAT appears to be an alternative to the standard testing method in dogs.</p>","PeriodicalId":23593,"journal":{"name":"Veterinary clinical pathology","volume":" ","pages":"23-29"},"PeriodicalIF":1.0000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13090106/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary clinical pathology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vcp.70088","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Thrombin generation assessment using calibrated automated thrombography (CAT) requires a standard volume of plasma (80 μL) and reagent (20 μL) run in triplicate. A CAT method using lower plasma and reagent volumes could benefit veterinary patients as it lowers the sampling burden in patients.

Objectives: To compare standard CAT methodology to a low plasma and low reagent volume CAT method in dogs.

Methods: Platelet-poor plasma samples were obtained by direct jugular venipuncture in dogs with low (n = 10), high (n = 10), and normal (n = 10) thrombin generation potential, recruited from a tertiary referral hospital. Method comparison was performed between standard CAT (80 μL plasma, 20 μL reagent- method 1) and low volume CAT (40 μL plasma, 10 μL reagent- method 2). Lag time (lag time); endogenous thrombin potential (ETP); peak (peak); and time to peak (ttpeak) were assessed on the thrombin generation curves.

Results: There was excellent agreement between methods 1 and 2 for all parameters. Lin's concordance coefficients were 0.97, 0.94, 0.96, and 0.96 for lag time, ETP, ttpeak, and peak, respectively. There was a small bias for all parameters (p < 0.05), resulting in a significant change for lag time only. There was a significant predictive linear equation that, when modeled, allowed the conversion of method 2 to method 1 values. The methods had similar variation when measuring TG variables.

Conclusions: Based on the results in this small group of dogs, we conclude that low-volume CAT appears to be an alternative to the standard testing method in dogs.

使用标准血浆量和低血浆量的狗校准自动血栓图的比较。
背景:使用校准的自动血栓成像(CAT)评估凝血酶生成需要标准体积的血浆(80 μL)和试剂(20 μL)一式三份。使用较低血浆和试剂体积的CAT方法可以使兽医患者受益,因为它降低了患者的采样负担。目的:比较标准CAT方法与低血浆低试剂量CAT方法。方法:从三级转诊医院招募凝血酶生成电位低(n = 10)、高(n = 10)和正常(n = 10)的犬,采用直接颈静脉穿刺法采集血小板差血浆标本。方法比较了标准CAT (80 μL血浆,20 μL试剂-方法1)和小容量CAT (40 μL血浆,10 μL试剂-方法2)。滞后时间(滞后时间);内源性凝血酶电位;峰(峰);测定凝血酶生成曲线的峰值时间(ttpeak)。结果:方法1和方法2的各项参数吻合良好。滞后时间、ETP、ttpeak和peak的Lin’s一致性系数分别为0.97、0.94、0.96和0.96。结论:基于这一小群狗的结果,我们得出结论,小容量CAT似乎是狗的标准测试方法的替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary clinical pathology
Veterinary clinical pathology 农林科学-兽医学
CiteScore
1.70
自引率
16.70%
发文量
133
审稿时长
18-36 weeks
期刊介绍: Veterinary Clinical Pathology is the official journal of the American Society for Veterinary Clinical Pathology (ASVCP) and the European Society of Veterinary Clinical Pathology (ESVCP). The journal''s mission is to provide an international forum for communication and discussion of scientific investigations and new developments that advance the art and science of laboratory diagnosis in animals. Veterinary Clinical Pathology welcomes original experimental research and clinical contributions involving domestic, laboratory, avian, and wildlife species in the areas of hematology, hemostasis, immunopathology, clinical chemistry, cytopathology, surgical pathology, toxicology, endocrinology, laboratory and analytical techniques, instrumentation, quality assurance, and clinical pathology education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书