{"title":"Ingestible active capsule for gastrointestinal microbiome sampling","authors":"Mohammed Hadi Shahadha,&nbsp;Andreas Voigt,&nbsp;Denise Gruner,&nbsp;Uwe Marschner,&nbsp;Maxime Le Floch,&nbsp;Jochen Hampe,&nbsp;Frank Brauer,&nbsp;Sebastian Schostek,&nbsp;Marco Luniak,&nbsp;Karlheinz Bock,&nbsp;Andreas Richter","doi":"10.1007/s10544-026-00802-4","DOIUrl":null,"url":null,"abstract":"<div><p>Various gastrointestinal disorders have been linked to gut microbiome dysbiosis, as it plays a critical role in immune regulation, metabolism, nutrient digestion, and pathogen suppression. However, the microbiome’s spatial variability across gastrointestinal segments and its intra- and interindividual differences complicate its study and clinical interpretation. While fecal DNA analysis is commonly used, stool samples only capture an accumulated signal and miss the spatial dynamics of microbial populations. To address this, we propose a modular sampling capsule capable of wirelessly collecting liquid. The capsule consists of two main modules: (i) an <i>actuator module</i> integrating a polymer-based microfluidic system with meltable wax-based opening valve, screen-printed microheater, cellulose membrane-based closing valve, evacuated sampling chamber with dried sample preservative material, filter membrane (size exclusion 150 μm), and sample extraction channel; and (ii) a <i>control electronic module</i> with communication, localization, and power supply units. The actuator module was validated <i>in vitro</i> using a diluted stool simulant (330 mg/mL) and an uncleaned porcine intestine. The opening valve activated within 3.6 ± 0.5 s at 120 ± 10 mA and 0.8 V. The sample was then filtered and aspirated into the sampling chamber within 1–2 s, and the closing valve sealed the inlet completely within 10 min. We overcame design, material, and fabrication challenges to construct an actuator module that functions effectively in liquids with variable physicochemical conditions (pH, chemical composition, viscosity, and particle size). These results demonstrate the feasibility of a controlled, segment-specific intestinal sampling capsule, representing a step towards precise and accurate microbiome profiling.</p><h3>Graphical abstract</h3><div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":490,"journal":{"name":"Biomedical Microdevices","volume":"28 1","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2026-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10544-026-00802-4.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Microdevices","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10544-026-00802-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Various gastrointestinal disorders have been linked to gut microbiome dysbiosis, as it plays a critical role in immune regulation, metabolism, nutrient digestion, and pathogen suppression. However, the microbiome’s spatial variability across gastrointestinal segments and its intra- and interindividual differences complicate its study and clinical interpretation. While fecal DNA analysis is commonly used, stool samples only capture an accumulated signal and miss the spatial dynamics of microbial populations. To address this, we propose a modular sampling capsule capable of wirelessly collecting liquid. The capsule consists of two main modules: (i) an actuator module integrating a polymer-based microfluidic system with meltable wax-based opening valve, screen-printed microheater, cellulose membrane-based closing valve, evacuated sampling chamber with dried sample preservative material, filter membrane (size exclusion 150 μm), and sample extraction channel; and (ii) a control electronic module with communication, localization, and power supply units. The actuator module was validated in vitro using a diluted stool simulant (330 mg/mL) and an uncleaned porcine intestine. The opening valve activated within 3.6 ± 0.5 s at 120 ± 10 mA and 0.8 V. The sample was then filtered and aspirated into the sampling chamber within 1–2 s, and the closing valve sealed the inlet completely within 10 min. We overcame design, material, and fabrication challenges to construct an actuator module that functions effectively in liquids with variable physicochemical conditions (pH, chemical composition, viscosity, and particle size). These results demonstrate the feasibility of a controlled, segment-specific intestinal sampling capsule, representing a step towards precise and accurate microbiome profiling.

Graphical abstract

用于胃肠道微生物组取样的可摄取活性胶囊
各种胃肠道疾病都与肠道微生物群失调有关,因为它在免疫调节、代谢、营养消化和病原体抑制中起着关键作用。然而,微生物组在胃肠道段的空间变异性及其个体内和个体间的差异使其研究和临床解释复杂化。虽然粪便DNA分析是常用的,但粪便样本只捕获累积的信号,而错过了微生物种群的空间动态。为了解决这个问题,我们提出了一种能够无线收集液体的模块化采样胶囊。该胶囊由两个主要模块组成:(i)执行器模块,该模块集成了基于聚合物的微流体系统,该微流体系统带有可熔融蜡基开启阀、丝印微加热器、基于纤维素膜的关闭阀、带有干燥样品防腐材料的真空取样室、过滤膜(尺寸隔离150 μm)和样品提取通道;以及(ii)具有通信、定位和电源单元的控制电子模块。使用稀释的粪便模拟剂(330 mg/mL)和未清洗的猪肠对致动器模块进行体外验证。在120±10 mA和0.8 V下,开启阀在3.6±0.5 s内激活。在1-2秒内将样品过滤并吸入采样室,关闭阀在10分钟内完全密封进样口。我们克服了设计、材料和制造方面的挑战,构建了一个执行器模块,该模块可以在可变物理化学条件(pH、化学成分、粘度和粒径)的液体中有效工作。这些结果证明了一种受控的、特定片段的肠道采样胶囊的可行性,代表了向精确和准确的微生物组分析迈出的一步。图形抽象
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Microdevices
Biomedical Microdevices 工程技术-工程:生物医学
CiteScore
6.90
自引率
3.60%
发文量
32
审稿时长
6 months
期刊介绍: Biomedical Microdevices: BioMEMS and Biomedical Nanotechnology is an interdisciplinary periodical devoted to all aspects of research in the medical diagnostic and therapeutic applications of Micro-Electro-Mechanical Systems (BioMEMS) and nanotechnology for medicine and biology. General subjects of interest include the design, characterization, testing, modeling and clinical validation of microfabricated systems, and their integration on-chip and in larger functional units. The specific interests of the Journal include systems for neural stimulation and recording, bioseparation technologies such as nanofilters and electrophoretic equipment, miniaturized analytic and DNA identification systems, biosensors, and micro/nanotechnologies for cell and tissue research, tissue engineering, cell transplantation, and the controlled release of drugs and biological molecules. Contributions reporting on fundamental and applied investigations of the material science, biochemistry, and physics of biomedical microdevices and nanotechnology are encouraged. A non-exhaustive list of fields of interest includes: nanoparticle synthesis, characterization, and validation of therapeutic or imaging efficacy in animal models; biocompatibility; biochemical modification of microfabricated devices, with reference to non-specific protein adsorption, and the active immobilization and patterning of proteins on micro/nanofabricated surfaces; the dynamics of fluids in micro-and-nano-fabricated channels; the electromechanical and structural response of micro/nanofabricated systems; the interactions of microdevices with cells and tissues, including biocompatibility and biodegradation studies; variations in the characteristics of the systems as a function of the micro/nanofabrication parameters.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书