Mohammed Hadi Shahadha, Andreas Voigt, Denise Gruner, Uwe Marschner, Maxime Le Floch, Jochen Hampe, Frank Brauer, Sebastian Schostek, Marco Luniak, Karlheinz Bock, Andreas Richter
{"title":"Ingestible active capsule for gastrointestinal microbiome sampling","authors":"Mohammed Hadi Shahadha, Andreas Voigt, Denise Gruner, Uwe Marschner, Maxime Le Floch, Jochen Hampe, Frank Brauer, Sebastian Schostek, Marco Luniak, Karlheinz Bock, Andreas Richter","doi":"10.1007/s10544-026-00802-4","DOIUrl":null,"url":null,"abstract":"<div><p>Various gastrointestinal disorders have been linked to gut microbiome dysbiosis, as it plays a critical role in immune regulation, metabolism, nutrient digestion, and pathogen suppression. However, the microbiome’s spatial variability across gastrointestinal segments and its intra- and interindividual differences complicate its study and clinical interpretation. While fecal DNA analysis is commonly used, stool samples only capture an accumulated signal and miss the spatial dynamics of microbial populations. To address this, we propose a modular sampling capsule capable of wirelessly collecting liquid. The capsule consists of two main modules: (i) an <i>actuator module</i> integrating a polymer-based microfluidic system with meltable wax-based opening valve, screen-printed microheater, cellulose membrane-based closing valve, evacuated sampling chamber with dried sample preservative material, filter membrane (size exclusion 150 μm), and sample extraction channel; and (ii) a <i>control electronic module</i> with communication, localization, and power supply units. The actuator module was validated <i>in vitro</i> using a diluted stool simulant (330 mg/mL) and an uncleaned porcine intestine. The opening valve activated within 3.6 ± 0.5 s at 120 ± 10 mA and 0.8 V. The sample was then filtered and aspirated into the sampling chamber within 1–2 s, and the closing valve sealed the inlet completely within 10 min. We overcame design, material, and fabrication challenges to construct an actuator module that functions effectively in liquids with variable physicochemical conditions (pH, chemical composition, viscosity, and particle size). These results demonstrate the feasibility of a controlled, segment-specific intestinal sampling capsule, representing a step towards precise and accurate microbiome profiling.</p><h3>Graphical abstract</h3><div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":490,"journal":{"name":"Biomedical Microdevices","volume":"28 1","pages":""},"PeriodicalIF":4.4000,"publicationDate":"2026-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10544-026-00802-4.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Microdevices","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10544-026-00802-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Various gastrointestinal disorders have been linked to gut microbiome dysbiosis, as it plays a critical role in immune regulation, metabolism, nutrient digestion, and pathogen suppression. However, the microbiome’s spatial variability across gastrointestinal segments and its intra- and interindividual differences complicate its study and clinical interpretation. While fecal DNA analysis is commonly used, stool samples only capture an accumulated signal and miss the spatial dynamics of microbial populations. To address this, we propose a modular sampling capsule capable of wirelessly collecting liquid. The capsule consists of two main modules: (i) an actuator module integrating a polymer-based microfluidic system with meltable wax-based opening valve, screen-printed microheater, cellulose membrane-based closing valve, evacuated sampling chamber with dried sample preservative material, filter membrane (size exclusion 150 μm), and sample extraction channel; and (ii) a control electronic module with communication, localization, and power supply units. The actuator module was validated in vitro using a diluted stool simulant (330 mg/mL) and an uncleaned porcine intestine. The opening valve activated within 3.6 ± 0.5 s at 120 ± 10 mA and 0.8 V. The sample was then filtered and aspirated into the sampling chamber within 1–2 s, and the closing valve sealed the inlet completely within 10 min. We overcame design, material, and fabrication challenges to construct an actuator module that functions effectively in liquids with variable physicochemical conditions (pH, chemical composition, viscosity, and particle size). These results demonstrate the feasibility of a controlled, segment-specific intestinal sampling capsule, representing a step towards precise and accurate microbiome profiling.
期刊介绍:
Biomedical Microdevices: BioMEMS and Biomedical Nanotechnology is an interdisciplinary periodical devoted to all aspects of research in the medical diagnostic and therapeutic applications of Micro-Electro-Mechanical Systems (BioMEMS) and nanotechnology for medicine and biology.
General subjects of interest include the design, characterization, testing, modeling and clinical validation of microfabricated systems, and their integration on-chip and in larger functional units. The specific interests of the Journal include systems for neural stimulation and recording, bioseparation technologies such as nanofilters and electrophoretic equipment, miniaturized analytic and DNA identification systems, biosensors, and micro/nanotechnologies for cell and tissue research, tissue engineering, cell transplantation, and the controlled release of drugs and biological molecules.
Contributions reporting on fundamental and applied investigations of the material science, biochemistry, and physics of biomedical microdevices and nanotechnology are encouraged. A non-exhaustive list of fields of interest includes: nanoparticle synthesis, characterization, and validation of therapeutic or imaging efficacy in animal models; biocompatibility; biochemical modification of microfabricated devices, with reference to non-specific protein adsorption, and the active immobilization and patterning of proteins on micro/nanofabricated surfaces; the dynamics of fluids in micro-and-nano-fabricated channels; the electromechanical and structural response of micro/nanofabricated systems; the interactions of microdevices with cells and tissues, including biocompatibility and biodegradation studies; variations in the characteristics of the systems as a function of the micro/nanofabrication parameters.