Engineered surfaces for biomedical implants: advances in coatings, materials, and techniques.

IF 7.7 Q1 ENGINEERING, BIOMEDICAL
Muhammad Usama Zaheer, Muhammad Hassan Razzaq, Emerson Coy, Mehmet Fatih Aycan, Yogendra Kumar Mishra
{"title":"Engineered surfaces for biomedical implants: advances in coatings, materials, and techniques.","authors":"Muhammad Usama Zaheer, Muhammad Hassan Razzaq, Emerson Coy, Mehmet Fatih Aycan, Yogendra Kumar Mishra","doi":"10.1088/2516-1091/ae4d91","DOIUrl":null,"url":null,"abstract":"<p><p>The longevity and performance of biomedical implants depend strongly on surface properties, motivating coatings that enhance biocompatibility, mechanical resilience, and resistance to wear and infection. This review analyzes state-of-the-art coatings for orthopedic and dental implants, linking material choice, deposition method, and demonstrated<i>in vitro</i>performance. Bioinert systems (e.g. TiN, diamond-like carbon), bioactive coatings such as hydroxyapatite and bioactive glass, and antibacterial approaches using silver-, zinc-oxide-, and graphene-based layers are compared for their effects on osseointegration, bacterial control, and durability. Deposition routes from plasma spraying to advanced methods including pulsed laser deposition, atomic layer deposition (ALD), and plasma-enhanced chemical vapor deposition are evaluated for adhesion, microstructure control, and clinical practicality. Across recent studies, nanostructured and multifunctional coatings consistently accelerate early osteogenic responses, ion- or carbon-modified hydroxyapatite improves interfacial bonding while adding antibacterial activity, conformal ultrathin films from ALD enhance corrosion resistance on complex geometries without impairing cell viability, and multilayer or hybrid architectures reduce tribocorrosion under cyclic loading. Remaining challenges include maintaining long-term stability and uniform coverage on intricate implant designs and scaling fabrication economically. Emerging directions focus on stimuli-responsive surfaces and biodegradable, drug-eluting coatings aimed at reducing infection risk and speeding integration, with the overall trajectory pointing toward coatings that couple mechanical reliability with targeted biological function.</p>","PeriodicalId":74582,"journal":{"name":"Progress in biomedical engineering (Bristol, England)","volume":" ","pages":""},"PeriodicalIF":7.7000,"publicationDate":"2026-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in biomedical engineering (Bristol, England)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2516-1091/ae4d91","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The longevity and performance of biomedical implants depend strongly on surface properties, motivating coatings that enhance biocompatibility, mechanical resilience, and resistance to wear and infection. This review analyzes state-of-the-art coatings for orthopedic and dental implants, linking material choice, deposition method, and demonstratedin vitroperformance. Bioinert systems (e.g. TiN, diamond-like carbon), bioactive coatings such as hydroxyapatite and bioactive glass, and antibacterial approaches using silver-, zinc-oxide-, and graphene-based layers are compared for their effects on osseointegration, bacterial control, and durability. Deposition routes from plasma spraying to advanced methods including pulsed laser deposition, atomic layer deposition (ALD), and plasma-enhanced chemical vapor deposition are evaluated for adhesion, microstructure control, and clinical practicality. Across recent studies, nanostructured and multifunctional coatings consistently accelerate early osteogenic responses, ion- or carbon-modified hydroxyapatite improves interfacial bonding while adding antibacterial activity, conformal ultrathin films from ALD enhance corrosion resistance on complex geometries without impairing cell viability, and multilayer or hybrid architectures reduce tribocorrosion under cyclic loading. Remaining challenges include maintaining long-term stability and uniform coverage on intricate implant designs and scaling fabrication economically. Emerging directions focus on stimuli-responsive surfaces and biodegradable, drug-eluting coatings aimed at reducing infection risk and speeding integration, with the overall trajectory pointing toward coatings that couple mechanical reliability with targeted biological function.

生物医学植入物的工程表面:涂层、材料和技术的进展。
生物医学植入物的使用寿命和性能在很大程度上取决于其表面特性、激发涂层的生物相容性、机械弹性以及对磨损和感染的抵抗力。这篇综述分析了骨科和牙科种植体的最新涂层,连接材料的选择,沉积方法和体外性能。生物惰性系统(如TiN、DLC)、生物活性涂层(如羟基磷灰石和生物活性玻璃)以及使用银、氧化锌和石墨烯基层的抗菌方法对骨整合、细菌控制和耐久性的影响进行了比较。从等离子喷涂到先进的方法,包括脉冲激光沉积、原子层沉积和等离子增强化学气相沉积,对粘附性、微观结构控制和临床实用性进行了评估。在最近的研究中,纳米结构和多功能涂层持续加速早期成骨反应,离子或碳修饰的羟基磷灰石在增加抗菌活性的同时改善界面键合,原子层沉积的保形超薄膜在不损害细胞活力的情况下增强了复杂几何形状的耐腐蚀性,多层或混合结构减少了循环载荷下的摩擦腐蚀。剩下的挑战包括在复杂的植入物设计中保持长期稳定性和均匀覆盖,以及经济地扩展制造。新兴方向集中在刺激响应表面和可生物降解的药物洗脱涂层,旨在降低感染风险和加速整合,总体轨迹指向将机械可靠性与目标生物功能结合起来的涂层。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
9.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书