The relationship between oocyte maturation and follicle size: A comparative analysis of 2D and 3D ultrasound.

IF 1.3 Q4 OBSTETRICS & GYNECOLOGY
Özge Karaosmanoğlu, Ayşen Yücetürk, Nuri Peker, Ömür Albayrak, Burak Elmas, İlke Özer Aslan, Bülent Tıraş
{"title":"The relationship between oocyte maturation and follicle size: A comparative analysis of 2D and 3D ultrasound.","authors":"Özge Karaosmanoğlu, Ayşen Yücetürk, Nuri Peker, Ömür Albayrak, Burak Elmas, İlke Özer Aslan, Bülent Tıraş","doi":"10.4274/tjod.galenos.2026.05763","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To compare the ability of three-dimensional (3D) and conventional two-dimensional (2D) ultrasound to predict oocyte maturity during in vitro fertilization cycles, and to evaluate their contribution to trigger timing and to the determination of optimal cut-off values for maximizing metaphase II (MII) oocyte yield using automated volume-calculation software.</p><p><strong>Materials and methods: </strong>Forty-three infertile women who had ≤5 follicles, were younger than 40 years, had a body mass index <30, and had no previous oocyte maturation problems were included in this retrospective study. Follicle diameter was measured using 2D ultrasound, while follicle volume was measured using 3D ultrasound with SonoAVC software. The obtained values were compared with those from MII oocytes, and receiver operating characteristic (ROC) analysis and logistic regression were performed.</p><p><strong>Results: </strong>A total of 203 oocytes were analyzed; 70% of them were in the MII stage. In the ROC analysis, the optimal cut-off for 2D measurement was determined to be 17.05 mm [area under curve (AUC)=0.737], and for 3D measurement, it was 1.83 cm³ (AUC=0.709). 2D measurements showed specificity, while 3D measurements showed sensitivity. In logistic regression analysis, both 2D diameter and 3D volume were found to be independent predictors of MII oocyte development.</p><p><strong>Conclusion: </strong>Our findings suggest that 3D ultrasound measurements may provide greater sensitivity for predicting oocyte maturity. However, falsepositive results may occur in the presence of multiple or nested follicles, and observer dependence cannot be completely eliminated. Therefore, optimization and large-scale validation studies are needed to improve the accuracy of the method.</p>","PeriodicalId":45340,"journal":{"name":"Turkish Journal of Obstetrics and Gynecology","volume":"23 1","pages":"64-70"},"PeriodicalIF":1.3000,"publicationDate":"2026-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12963798/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Obstetrics and Gynecology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4274/tjod.galenos.2026.05763","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/29 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To compare the ability of three-dimensional (3D) and conventional two-dimensional (2D) ultrasound to predict oocyte maturity during in vitro fertilization cycles, and to evaluate their contribution to trigger timing and to the determination of optimal cut-off values for maximizing metaphase II (MII) oocyte yield using automated volume-calculation software.

Materials and methods: Forty-three infertile women who had ≤5 follicles, were younger than 40 years, had a body mass index <30, and had no previous oocyte maturation problems were included in this retrospective study. Follicle diameter was measured using 2D ultrasound, while follicle volume was measured using 3D ultrasound with SonoAVC software. The obtained values were compared with those from MII oocytes, and receiver operating characteristic (ROC) analysis and logistic regression were performed.

Results: A total of 203 oocytes were analyzed; 70% of them were in the MII stage. In the ROC analysis, the optimal cut-off for 2D measurement was determined to be 17.05 mm [area under curve (AUC)=0.737], and for 3D measurement, it was 1.83 cm³ (AUC=0.709). 2D measurements showed specificity, while 3D measurements showed sensitivity. In logistic regression analysis, both 2D diameter and 3D volume were found to be independent predictors of MII oocyte development.

Conclusion: Our findings suggest that 3D ultrasound measurements may provide greater sensitivity for predicting oocyte maturity. However, falsepositive results may occur in the presence of multiple or nested follicles, and observer dependence cannot be completely eliminated. Therefore, optimization and large-scale validation studies are needed to improve the accuracy of the method.

Abstract Image

Abstract Image

Abstract Image

卵母细胞成熟与卵泡大小的关系:二维和三维超声的比较分析。
目的:比较三维(3D)和传统二维(2D)超声在体外受精周期中预测卵母细胞成熟度的能力,并评估它们对触发时间的贡献,以及使用自动体积计算软件确定最大化中期II (MII)卵母细胞产量的最佳截止值。材料与方法:43例年龄小于40岁,卵泡≤5个的不孕症妇女,体重指数为:结果:共分析卵母细胞203个;其中70%为MII期。在ROC分析中,二维测量的最佳截止值为17.05 mm[曲线下面积(AUC)=0.737],三维测量的最佳截止值为1.83 cm³(AUC=0.709)。二维测量显示特异性,而三维测量显示敏感性。在logistic回归分析中,发现二维直径和三维体积都是MII卵母细胞发育的独立预测因子。结论:我们的研究结果表明,三维超声测量可以为预测卵母细胞成熟度提供更高的灵敏度。然而,在存在多个或嵌套卵泡时可能出现假阳性结果,并且不能完全消除对观察者的依赖。因此,需要进行优化和大规模的验证研究来提高方法的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.10
自引率
0.00%
发文量
1
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书