Stefanie Weigel, Petra Wunderlich, Alexander Sommer, Jörg Czwoydzinski, Pascal Andreas Thomas Baltzer, Cornelia Lieselotte Angelika Dewald, Heike Preibsch, Stephanie Sauer, Katja C Siegmann-Luz, Evelyn Wenkel, Caroline Wilpert, Sophia Freya Ulrike Blum
{"title":"Digital breast tomosynthesis and reading with artificial intelligence.","authors":"Stefanie Weigel, Petra Wunderlich, Alexander Sommer, Jörg Czwoydzinski, Pascal Andreas Thomas Baltzer, Cornelia Lieselotte Angelika Dewald, Heike Preibsch, Stephanie Sauer, Katja C Siegmann-Luz, Evelyn Wenkel, Caroline Wilpert, Sophia Freya Ulrike Blum","doi":"10.1055/a-2796-5225","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Digital breast tomosynthesis (DBT) increases sensitivity and specificity compared to digital mammography (DM) in the early detection of breast cancer. The potential of artificial intelligence (AI) for mammographic interpretation resulting in workload reduction is increasingly being reported.</p><p><strong>Method: </strong>Presentation of the current evidence on the efficacy of DBT versus DM in population-based breast cancer screening and its support by AI. Narrative review with topic-led literature search of comparative studies of DBT and DM and review of the use of AI in PubMed from 01/2016 to 09/2025.</p><p><strong>Results: </strong>In 42 international studies, the breast cancer detection rate was significantly higher with DBT + DM (6.4‰) and DBT + synthetic mammography (SM) (7.4‰) than with DM (4.7‰). Concordantly, the randomized TOSYMA study reported a higher invasive breast cancer detection rate with DBT + SM (7.1‰) versus DM (4.8‰) with a lower false-positive recall rate (first round -15.6‰). The positive predictive value (PPV) of recall was - consistent with meta-analyses - higher (+4.9%), as was the reading time. With a smaller number of AI studies on DBT than DM, a DBT meta-analysis reported a higher sensitivity of AI alone (89%) than by readers (78%), with a lower specificity of AI. DBT with AI-assisted reading compared to human reading alone increased the detection rate in a prospective study by +3.8‰ without a marked change in the recall rate (+0.8%).</p><p><strong>Conclusion: </strong>DBT increases breast cancer detection compared to DM with more favorable process parameters. AI reporting strategies can further increase sensitivity and reduce human workload. The influence of DBT and AI on reducing the interval cancer rate as a measure of efficiency has not yet been proven.</p><p><strong>Key points: </strong>· DBT implementation in population-based breast cancer screening is being reviewed internationally.. · In case of DM replacement, AI reading concepts will become more important.. · Evidence of the long-term effectiveness of DBT and AI is limited..</p><p><strong>Citation format: </strong>· Weigel S, Wunderlich P, Sommer A et al. Digital breast tomosynthesis and reading with artificial intelligence. Rofo 2026; DOI 10.1055/a-2796-5225.</p>","PeriodicalId":21490,"journal":{"name":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","volume":" ","pages":"1271-1281"},"PeriodicalIF":2.0000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rofo-fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1055/a-2796-5225","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Digital breast tomosynthesis (DBT) increases sensitivity and specificity compared to digital mammography (DM) in the early detection of breast cancer. The potential of artificial intelligence (AI) for mammographic interpretation resulting in workload reduction is increasingly being reported.
Method: Presentation of the current evidence on the efficacy of DBT versus DM in population-based breast cancer screening and its support by AI. Narrative review with topic-led literature search of comparative studies of DBT and DM and review of the use of AI in PubMed from 01/2016 to 09/2025.
Results: In 42 international studies, the breast cancer detection rate was significantly higher with DBT + DM (6.4‰) and DBT + synthetic mammography (SM) (7.4‰) than with DM (4.7‰). Concordantly, the randomized TOSYMA study reported a higher invasive breast cancer detection rate with DBT + SM (7.1‰) versus DM (4.8‰) with a lower false-positive recall rate (first round -15.6‰). The positive predictive value (PPV) of recall was - consistent with meta-analyses - higher (+4.9%), as was the reading time. With a smaller number of AI studies on DBT than DM, a DBT meta-analysis reported a higher sensitivity of AI alone (89%) than by readers (78%), with a lower specificity of AI. DBT with AI-assisted reading compared to human reading alone increased the detection rate in a prospective study by +3.8‰ without a marked change in the recall rate (+0.8%).
Conclusion: DBT increases breast cancer detection compared to DM with more favorable process parameters. AI reporting strategies can further increase sensitivity and reduce human workload. The influence of DBT and AI on reducing the interval cancer rate as a measure of efficiency has not yet been proven.
Key points: · DBT implementation in population-based breast cancer screening is being reviewed internationally.. · In case of DM replacement, AI reading concepts will become more important.. · Evidence of the long-term effectiveness of DBT and AI is limited..
Citation format: · Weigel S, Wunderlich P, Sommer A et al. Digital breast tomosynthesis and reading with artificial intelligence. Rofo 2026; DOI 10.1055/a-2796-5225.
期刊介绍:
Die RöFo veröffentlicht Originalarbeiten, Übersichtsartikel und Fallberichte aus dem Bereich der Radiologie und den weiteren bildgebenden Verfahren in der Medizin. Es dürfen nur Arbeiten eingereicht werden, die noch nicht veröffentlicht sind und die auch nicht gleichzeitig einer anderen Zeitschrift zur Veröffentlichung angeboten wurden. Alle eingereichten Beiträge unterliegen einer sorgfältigen fachlichen Begutachtung.
Gegründet 1896 – nur knapp 1 Jahr nach der Entdeckung der Röntgenstrahlen durch C.W. Röntgen – blickt die RöFo auf über 100 Jahre Erfahrung als wichtigstes Publikationsmedium in der deutschsprachigen Radiologie zurück. Sie ist damit die älteste radiologische Fachzeitschrift und schafft es erfolgreich, lange Kontinuität mit dem Anspruch an wissenschaftliches Publizieren auf internationalem Niveau zu verbinden. Durch ihren zentralen Platz im Verlagsprogramm stellte die RöFo die Basis für das heute umfassende und erfolgreiche Radiologie-Medienangebot im Georg Thieme Verlag.
Besonders eng verbunden ist die RöFo mit der Geschichte der Röntgengesellschaften in Deutschland und Österreich. Sie ist offizielles Organ von DRG und ÖRG und die Mitglieder der Fachgesellschaften erhalten die Zeitschrift im Rahmen ihrer Mitgliedschaft. Mit ihrem wissenschaftlichen Kernteil und dem eigenen Mitteilungsteil der Fachgesellschaften bietet die RöFo Monat für Monat ein Forum für den Austausch von Inhalten und Botschaften der radiologischen Community im deutschsprachigen Raum.