A simple hydrofluoric acid-free pressurized-cavity microwave-assisted acid digestion method for determination of impurity elements in recycled carbon fibers with ICP-MS

IF 2 4区 化学 Q3 CHEMISTRY, ANALYTICAL
Tetsuya Nakazato, Yoshiki Makino
{"title":"A simple hydrofluoric acid-free pressurized-cavity microwave-assisted acid digestion method for determination of impurity elements in recycled carbon fibers with ICP-MS","authors":"Tetsuya Nakazato,&nbsp;Yoshiki Makino","doi":"10.1007/s44211-026-00886-1","DOIUrl":null,"url":null,"abstract":"<div><p>A simple method was proposed for the determination of 13 impurity elements (Na, Mg, Al, K, Ca, Ti, Cr, Fe, Co, Ni, Cu, Zn, and Pb) in recycled carbon fibers (rCFs) using pressurized-cavity microwave-assisted acid digestion without hydrofluoric acid (HF) combined with inductively coupled plasma mass spectrometry. Elevating the digestion temperature to 280 °C under pressurized conditions facilitated the dissolution of the target elements in rCF, even when present in refractory forms. Because certified reference materials of rCF samples for determining impurity elements were unavailable, the validity of the proposed method was confirmed by comparing its analytical results with those obtained using a HF-added digestion method, which completely decomposes silica, followed by the dissolution of the bound target elements. The proposed method was further validated by analyzing carbon- and metal-based certified reference materials and metal oxides as analogous to the refractory components of rCF. However, the limited decomposition of refractory rutile-type titania suggests an upper limit of 890 mg/kg for titanium determination using the proposed HF-free method. The limits of detection ranged from 0.0014 mg/kg for cobalt to 0.72 mg/kg for potassium. Ten of the 13 elements showed lower limits than those of the HF-added method because of less contamination. Operationally, the HF-free method is safer and simpler because it avoids the use of hazardous HF and does not require HF-elimination treatment.</p><h3>Graphical abstract</h3><div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":7802,"journal":{"name":"Analytical Sciences","volume":"42 4","pages":"257 - 267"},"PeriodicalIF":2.0000,"publicationDate":"2026-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13013236/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Sciences","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s44211-026-00886-1","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

A simple method was proposed for the determination of 13 impurity elements (Na, Mg, Al, K, Ca, Ti, Cr, Fe, Co, Ni, Cu, Zn, and Pb) in recycled carbon fibers (rCFs) using pressurized-cavity microwave-assisted acid digestion without hydrofluoric acid (HF) combined with inductively coupled plasma mass spectrometry. Elevating the digestion temperature to 280 °C under pressurized conditions facilitated the dissolution of the target elements in rCF, even when present in refractory forms. Because certified reference materials of rCF samples for determining impurity elements were unavailable, the validity of the proposed method was confirmed by comparing its analytical results with those obtained using a HF-added digestion method, which completely decomposes silica, followed by the dissolution of the bound target elements. The proposed method was further validated by analyzing carbon- and metal-based certified reference materials and metal oxides as analogous to the refractory components of rCF. However, the limited decomposition of refractory rutile-type titania suggests an upper limit of 890 mg/kg for titanium determination using the proposed HF-free method. The limits of detection ranged from 0.0014 mg/kg for cobalt to 0.72 mg/kg for potassium. Ten of the 13 elements showed lower limits than those of the HF-added method because of less contamination. Operationally, the HF-free method is safer and simpler because it avoids the use of hazardous HF and does not require HF-elimination treatment.

Graphical abstract

无氢氟酸加压腔微波辅助酸消解法测定再生碳纤维中的杂质元素。
采用加压腔微波辅助无氢氟酸消解-电感耦合等离子体质谱法测定再生碳纤维(rcf)中的13种杂质元素(Na、Mg、Al、K、Ca、Ti、Cr、Fe、Co、Ni、Cu、Zn、Pb)。在加压条件下,将消解温度提高到280℃有助于目标元素在rCF中的溶解,即使以难熔形式存在。由于无法获得用于测定杂质元素的rCF样品的认证标准物质,因此通过将所提出方法的分析结果与添加hf的消解方法的分析结果进行比较,证实了所提出方法的有效性。添加hf的消解方法完全分解二氧化硅,然后溶解结合的目标元素。通过分析碳基和金属基认证标准物质以及类似于rCF耐火成分的金属氧化物,进一步验证了所提出的方法。然而,难熔金红石型二氧化钛的有限分解表明,采用该方法测定钛的上限为890 mg/kg。检出限从钴的0.0014 mg/kg到钾的0.72 mg/kg不等。由于污染较少,13种元素中有10种比添加hf的方法的限低。操作上,无HF方法更安全、更简单,因为它避免了危险HF的使用,也不需要消除HF的处理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Sciences
Analytical Sciences 化学-分析化学
CiteScore
2.90
自引率
18.80%
发文量
232
审稿时长
1 months
期刊介绍: Analytical Sciences is an international journal published monthly by The Japan Society for Analytical Chemistry. The journal publishes papers on all aspects of the theory and practice of analytical sciences, including fundamental and applied, inorganic and organic, wet chemical and instrumental methods. This publication is supported in part by the Grant-in-Aid for Publication of Scientific Research Result of the Japanese Ministry of Education, Culture, Sports, Science and Technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书