Taiyo Ishikawa;Go Akamatsu;Hideaki Tashima;Fumihiko Nishikido;Fumio Hashimoto;Ryosuke Ota;Hideaki Haneishi;Sun Il Kwon;Simon R. Cherry;Taiga Yamaya
{"title":"Imaging Simulation of a Dual-Panel PET Geometry With Ultrafast TOF Detectors","authors":"Taiyo Ishikawa;Go Akamatsu;Hideaki Tashima;Fumihiko Nishikido;Fumio Hashimoto;Ryosuke Ota;Hideaki Haneishi;Sun Il Kwon;Simon R. Cherry;Taiga Yamaya","doi":"10.1109/TRPMS.2025.3594356","DOIUrl":null,"url":null,"abstract":"In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response. Cherenkov-radiator-integrated microchannel-plate photomultiplier tubes have achieved 30-ps TOF resolution, demonstrating cross-sectional imaging without reconstruction. Such ultrafast TOF detectors would free PET from conventional ring geometries. Therefore, this study aimed at investigating imaging characteristics of a dual-panel PET with ultrafast TOF detectors using Geant4 simulation. Two detector panels (<inline-formula> <tex-math>$137\\times 137$ </tex-math></inline-formula> mm2), which consisted of 5.0-mm thick bismuth germanate pixelized crystals with a 5.75-mm pitch, were placed face-to-face at a 300-mm distance. Imaging characteristics with various TOF resolutions from 30 to 90 ps were evaluated. Because, degraded efficiency may cancel TOF gain in image quality, detection efficiency was also parameterized by reducing coincidence counts. Data acquisitions for a numerical multirod and uniform phantom (21 MBq) and a modified NEMA NU2 image quality phantom were simulated for 600 s. Results of the maximum likelihood expectation maximization (MLEM) reconstruction were compared with those of a backprojection (i.e., no reconstruction). The dual-panel PET required a 40-ps TOF resolution to have a similar spatial resolution to that of a non-TOF ring PET (300-mm in diameter) for the same detection efficiency. TOF showed benefit in the reconstruction of image quality phantom with 40% efficiency, and the image noise with 20% efficiency at 30-ps TOF was similar to the complete efficiency at 40-ps TOF. MLEM provided better imaging performance than backprojection, even at 30-ps TOF. The feasibility of the proposed dual-panel PET was shown.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":"10 3","pages":"418-426"},"PeriodicalIF":3.8000,"publicationDate":"2025-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11105482/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response. Cherenkov-radiator-integrated microchannel-plate photomultiplier tubes have achieved 30-ps TOF resolution, demonstrating cross-sectional imaging without reconstruction. Such ultrafast TOF detectors would free PET from conventional ring geometries. Therefore, this study aimed at investigating imaging characteristics of a dual-panel PET with ultrafast TOF detectors using Geant4 simulation. Two detector panels ($137\times 137$ mm2), which consisted of 5.0-mm thick bismuth germanate pixelized crystals with a 5.75-mm pitch, were placed face-to-face at a 300-mm distance. Imaging characteristics with various TOF resolutions from 30 to 90 ps were evaluated. Because, degraded efficiency may cancel TOF gain in image quality, detection efficiency was also parameterized by reducing coincidence counts. Data acquisitions for a numerical multirod and uniform phantom (21 MBq) and a modified NEMA NU2 image quality phantom were simulated for 600 s. Results of the maximum likelihood expectation maximization (MLEM) reconstruction were compared with those of a backprojection (i.e., no reconstruction). The dual-panel PET required a 40-ps TOF resolution to have a similar spatial resolution to that of a non-TOF ring PET (300-mm in diameter) for the same detection efficiency. TOF showed benefit in the reconstruction of image quality phantom with 40% efficiency, and the image noise with 20% efficiency at 30-ps TOF was similar to the complete efficiency at 40-ps TOF. MLEM provided better imaging performance than backprojection, even at 30-ps TOF. The feasibility of the proposed dual-panel PET was shown.