Reliability of a Novel Qualitative Assessment Tool for Evaluating a Run Plant Task.

IF 2.4 Q3 SPORT SCIENCES
International Journal of Sports Physical Therapy Pub Date : 2026-03-02 eCollection Date: 2026-01-01 DOI:10.26603/001c.156437
Lauren Butler, Ashley Erdman, Alexa Martinez, Sierra Tate, Amie DeVerna, Sophia Ulman
{"title":"Reliability of a Novel Qualitative Assessment Tool for Evaluating a Run Plant Task.","authors":"Lauren Butler, Ashley Erdman, Alexa Martinez, Sierra Tate, Amie DeVerna, Sophia Ulman","doi":"10.26603/001c.156437","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Young female athletes have a substantial risk of suffering an anterior cruciate ligament (ACL) injury, in part due to sex-specific movement patterns. Injury prevention strategies targeting movement errors during a deceleration task may help decrease the associated risk. In order to enhance preventive interventions, screening tools to identify at-risk individuals are vital.</p><p><strong>Hypothesis/purpose: </strong>To assess intra- and inter-rater reliability of a qualitative assessment of trunk and lower extremity alignment during a run plant task. It was hypothesized that the tool would demonstrate good to excellent intra- and inter-rater reliability.</p><p><strong>Study design: </strong>Repeated measures.</p><p><strong>Methods: </strong>Two Raters assessed videos of 25 healthy female athletes (ages 12-17 years) performing a run plant task. Female athletes were chosen due to their increased ACL injury risk. Raters used a qualitative checklist to assess trunk and lower extremity alignment, awarding one point for each observed movement fault. Item scores were then summed to generate a total score. Each video was scored twice with a two-week washout period in-between. Intraclass correlation coefficients (ICC) for each scoring item and the overall total score were calculated with a 2-way mixed-effect model and 95% confidence intervals (95% CIs) for inter- and intra-rater reliability.</p><p><strong>Results: </strong>Intra-rater reliability was poor to moderate (Rater 1 ICC = 0.43, 95% CI 0.12-0.73; Rater 2 ICC = 0.54, 95% CI 0.20-0.87). Inter-rater reliability was moderate in round one (ICC = 0.66, 95% CI 0.41-0.90) and poor in round two (ICC = 0.32, 95% CI 0.02-0.63). Medial foot position was the only item to achieve good intra- and inter-rater reliability. Sagittal alignment also demonstrated good inter-rater reliability. In both rounds, dynamic valgus and preparatory deceleration steps were consistently marked as present (100% agreement), and lateral foot position was consistently marked as not present (100% agreement), by both Raters for all athletes.</p><p><strong>Conclusion: </strong>While some individual items showed good reliability, several items and the total score failed to achieve acceptable reliability. Despite lower ICC values for dynamic valgus, preparatory deceleration steps, and lateral foot position, percent agreement was high. The skew and limited variability in these items likely influenced ICC estimates, suggesting that Rater consistency may be underestimated. Refinement of scoring item definitions for these items is needed prior to clinical application of the tool.</p><p><strong>Level of evidence: </strong>Level 2, diagnosis.</p>","PeriodicalId":47892,"journal":{"name":"International Journal of Sports Physical Therapy","volume":"21 3","pages":"281-290"},"PeriodicalIF":2.4000,"publicationDate":"2026-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12952927/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Sports Physical Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26603/001c.156437","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Young female athletes have a substantial risk of suffering an anterior cruciate ligament (ACL) injury, in part due to sex-specific movement patterns. Injury prevention strategies targeting movement errors during a deceleration task may help decrease the associated risk. In order to enhance preventive interventions, screening tools to identify at-risk individuals are vital.

Hypothesis/purpose: To assess intra- and inter-rater reliability of a qualitative assessment of trunk and lower extremity alignment during a run plant task. It was hypothesized that the tool would demonstrate good to excellent intra- and inter-rater reliability.

Study design: Repeated measures.

Methods: Two Raters assessed videos of 25 healthy female athletes (ages 12-17 years) performing a run plant task. Female athletes were chosen due to their increased ACL injury risk. Raters used a qualitative checklist to assess trunk and lower extremity alignment, awarding one point for each observed movement fault. Item scores were then summed to generate a total score. Each video was scored twice with a two-week washout period in-between. Intraclass correlation coefficients (ICC) for each scoring item and the overall total score were calculated with a 2-way mixed-effect model and 95% confidence intervals (95% CIs) for inter- and intra-rater reliability.

Results: Intra-rater reliability was poor to moderate (Rater 1 ICC = 0.43, 95% CI 0.12-0.73; Rater 2 ICC = 0.54, 95% CI 0.20-0.87). Inter-rater reliability was moderate in round one (ICC = 0.66, 95% CI 0.41-0.90) and poor in round two (ICC = 0.32, 95% CI 0.02-0.63). Medial foot position was the only item to achieve good intra- and inter-rater reliability. Sagittal alignment also demonstrated good inter-rater reliability. In both rounds, dynamic valgus and preparatory deceleration steps were consistently marked as present (100% agreement), and lateral foot position was consistently marked as not present (100% agreement), by both Raters for all athletes.

Conclusion: While some individual items showed good reliability, several items and the total score failed to achieve acceptable reliability. Despite lower ICC values for dynamic valgus, preparatory deceleration steps, and lateral foot position, percent agreement was high. The skew and limited variability in these items likely influenced ICC estimates, suggesting that Rater consistency may be underestimated. Refinement of scoring item definitions for these items is needed prior to clinical application of the tool.

Level of evidence: Level 2, diagnosis.

一种评估运行工厂任务的新型定性评估工具的可靠性。
背景:年轻女运动员有很大的前交叉韧带(ACL)损伤的风险,部分原因是由于性别特定的运动模式。针对减速任务中动作错误的伤害预防策略可能有助于降低相关风险。为了加强预防干预,识别高危人群的筛查工具至关重要。假设/目的:评估在运行工厂任务中对躯干和下肢对齐进行定性评估的内部和内部可靠性。假设该工具将表现出良好的内部和内部可靠性。研究设计:重复测量。方法:两位评分者评估了25名健康女运动员(12-17岁)执行跑步植物任务的视频。选择女运动员是因为她们的前交叉韧带损伤风险增加。评分者使用一个定性的检查表来评估躯干和下肢的对齐,每观察到一个运动错误就给1分。然后将项目得分相加以生成总分。每个视频都被评分两次,中间有两周的洗脱期。每个评分项目的类内相关系数(ICC)和总得分采用双向混合效应模型和95%置信区间(95% ci)来计算评分间和评分内的信度。结果:评分者内部信度差至中等(评分者1 ICC = 0.43, 95% CI 0.12-0.73;评分者2 ICC = 0.54, 95% CI 0.20-0.87)。第一轮的评估间信度中等(ICC = 0.66, 95% CI 0.41-0.90),第二轮的评估间信度较差(ICC = 0.32, 95% CI 0.02-0.63)。内侧足位是唯一获得良好的内部和内部信度的项目。矢状对齐也显示出良好的评分间信度。在两轮中,两名评判员对所有运动员的动态外翻和预备减速步骤一致标记为存在(100%一致),而侧足位置一致标记为不存在(100%一致)。结论:部分单项信度较好,但部分单项及总分信度未达到可接受水平。尽管动态外翻、预备减速步骤和侧足位置的ICC值较低,但一致性百分比很高。这些项目的倾斜和有限的变异性可能影响了ICC的估计,这表明可能低估了Rater的一致性。在临床应用该工具之前,需要对这些项目的评分项目定义进行细化。证据等级:2级,诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.50
自引率
5.90%
发文量
124
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书