Comparison of visual performance between three enhanced monofocal intraocular lenses under different refractive targets.

IF 2.7 3区 医学 Q2 OPHTHALMOLOGY
Japanese Journal of Ophthalmology Pub Date : 2026-07-01 Epub Date: 2026-03-04 DOI:10.1007/s10384-026-01339-y
Hisaharu Suzuki, Miho Nishiyama
{"title":"Comparison of visual performance between three enhanced monofocal intraocular lenses under different refractive targets.","authors":"Hisaharu Suzuki, Miho Nishiyama","doi":"10.1007/s10384-026-01339-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the monocular uncorrected visual acuity (UCVA) and contrast sensitivity (CS) of three enhanced monofocal intraocular lenses (IOLs) under emmetropic and mild myopic refractive targets.</p><p><strong>Study design: </strong>Single-center retrospective observational study.</p><p><strong>Methods: </strong>Among 198 patients (244 eyes) who underwent uneventful cataract surgery with enhanced monofocal IOL implantation (Tecnis Eyhance [DIB00V, E group], Vivinex Impress [XY1-EM, I group], NIDEK NSP-3 [N group]) with emmetropia or mild myopia (-1.00D), refractive targets, monocular UCVA at six different distances (5, 1, 70, 50, 40, and 30 cm) and CS with and without glare were assessed 1 month postoperatively and compared using the Kruskal-Wallis test followed by the Steel-Dwass post-hoc test.</p><p><strong>Results: </strong>In the emmetropic group, UCVA for all IOLs achieved ≤ 0.2 logMAR from 5 m to 50 cm, with significantly better UCVA at 5 m in the E than I group (p = 0.0300) and at 50 cm in the I than N group (p = 0.0242). For mild myopia, the N group achieved better UCVA at 5 m (p = 0.0066), the I group showed superior near-visual acuity at 30 cm than the E group (p = 0.0457), and UCVA for all IOLs achieved ≤ 0.2 logMAR from 1 m to 40 cm, with the highest CS at 6, 12, and 18 cycles per degree, with and without glare, in the E group. These findings suggest that combining enhanced monofocal IOLs with mild myopic targeting (-1.0 D) may optimize functional vision for everyday activities, particularly in older adults who rely on safe intermediate and near vision in daily life.</p><p><strong>Conclusions: </strong>All IOLs showed good UCVA. The E, I, and N groups demonstrated balanced visual performance, with superior contrast sensitivity, superior near-to-intermediate vision, and superior distance vision, respectively.</p>","PeriodicalId":14563,"journal":{"name":"Japanese Journal of Ophthalmology","volume":" ","pages":"813-819"},"PeriodicalIF":2.7000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10384-026-01339-y","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the monocular uncorrected visual acuity (UCVA) and contrast sensitivity (CS) of three enhanced monofocal intraocular lenses (IOLs) under emmetropic and mild myopic refractive targets.

Study design: Single-center retrospective observational study.

Methods: Among 198 patients (244 eyes) who underwent uneventful cataract surgery with enhanced monofocal IOL implantation (Tecnis Eyhance [DIB00V, E group], Vivinex Impress [XY1-EM, I group], NIDEK NSP-3 [N group]) with emmetropia or mild myopia (-1.00D), refractive targets, monocular UCVA at six different distances (5, 1, 70, 50, 40, and 30 cm) and CS with and without glare were assessed 1 month postoperatively and compared using the Kruskal-Wallis test followed by the Steel-Dwass post-hoc test.

Results: In the emmetropic group, UCVA for all IOLs achieved ≤ 0.2 logMAR from 5 m to 50 cm, with significantly better UCVA at 5 m in the E than I group (p = 0.0300) and at 50 cm in the I than N group (p = 0.0242). For mild myopia, the N group achieved better UCVA at 5 m (p = 0.0066), the I group showed superior near-visual acuity at 30 cm than the E group (p = 0.0457), and UCVA for all IOLs achieved ≤ 0.2 logMAR from 1 m to 40 cm, with the highest CS at 6, 12, and 18 cycles per degree, with and without glare, in the E group. These findings suggest that combining enhanced monofocal IOLs with mild myopic targeting (-1.0 D) may optimize functional vision for everyday activities, particularly in older adults who rely on safe intermediate and near vision in daily life.

Conclusions: All IOLs showed good UCVA. The E, I, and N groups demonstrated balanced visual performance, with superior contrast sensitivity, superior near-to-intermediate vision, and superior distance vision, respectively.

不同屈光目标下三种增强单焦点人工晶体视觉性能的比较。
目的:比较三种增强单焦点人工晶状体(iol)在准远视和轻度近视屈光指标下的单眼未矫正视力(UCVA)和对比敏感度(CS)。研究设计:单中心回顾性观察性研究。方法:对198例(244只眼)斜视或轻度近视(-1.00D)患者(Tecnis Eyhance [DIB00V, E组]、Vivinex Impress [XY1-EM, I组]、NIDEK NSP-3 [N组]),术后1个月对屈光指标、6个不同距离(5、1、70、50、40、30 cm)的单眼UCVA和有无眩光的CS进行评估,并采用Kruskal-Wallis检验和Steel-Dwass后视检验进行比较。结果:正视镜组5 ~ 50 cm处所有iol的UCVA均达到≤0.2 logMAR,其中5 m处E组明显优于I组(p = 0.0300), 50 cm处I组明显优于N组(p = 0.0242)。对于轻度近视,N组在5 m处获得了更好的UCVA (p = 0.0066), I组在30 cm处的近视力优于E组(p = 0.0457),所有iol的UCVA在1 m至40 cm处均达到≤0.2 logMAR,在有眩光和无眩光的情况下,E组的最高CS为6、12和18 cycles /度数。这些发现表明,将增强的单焦点iol与轻度近视瞄准(-1.0 D)相结合,可以优化日常活动的功能视力,特别是在日常生活中依赖安全的中视力和近视力的老年人中。结论:所有人工晶状体均具有良好的UCVA。E组、I组和N组表现出平衡的视觉表现,分别具有优越的对比敏感度、优越的近中视力和优越的远距离视力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.80
自引率
8.30%
发文量
65
审稿时长
6-12 weeks
期刊介绍: The Japanese Journal of Ophthalmology (JJO) was inaugurated in 1957 as a quarterly journal published in English by the Ophthalmology Department of the University of Tokyo, with the aim of disseminating the achievements of Japanese ophthalmologists worldwide. JJO remains the only Japanese ophthalmology journal published in English. In 1997, the Japanese Ophthalmological Society assumed the responsibility for publishing the Japanese Journal of Ophthalmology as its official English-language publication. Currently the journal is published bimonthly and accepts papers from authors worldwide. JJO has become an international interdisciplinary forum for the publication of basic science and clinical research papers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书