Development of Superfluid Helium-3 Bolometry Using Nanowire Resonators with SQUID Readout for the QUEST-DMC Experiment

IF 1.2 3区 物理与天体物理 Q4 PHYSICS, APPLIED
E. Leason, L. V. Levitin, S. Autti, E. Bloomfield, A. Casey, N. Darvishi, N. Eng, P. Franchini, R. P. Haley, P. J. Heikkinen, A. Jennings, A. Kemp, J. March-Russell, A. Mayer, J. Monroe, D. Muenstermann, M. T. Noble, J. R. Prance, X. Rojas, T. Salmon, J. Saunders, J. Smirnov, R. Smith, M. D. Thompson, A. Thomson, A. Ting, V. Tsepelin, S. M. West, L. Whitehead, D. E. Zmeev, QUEST-DMC Collaboration
{"title":"Development of Superfluid Helium-3 Bolometry Using Nanowire Resonators with SQUID Readout for the QUEST-DMC Experiment","authors":"E. Leason,&nbsp;L. V. Levitin,&nbsp;S. Autti,&nbsp;E. Bloomfield,&nbsp;A. Casey,&nbsp;N. Darvishi,&nbsp;N. Eng,&nbsp;P. Franchini,&nbsp;R. P. Haley,&nbsp;P. J. Heikkinen,&nbsp;A. Jennings,&nbsp;A. Kemp,&nbsp;J. March-Russell,&nbsp;A. Mayer,&nbsp;J. Monroe,&nbsp;D. Muenstermann,&nbsp;M. T. Noble,&nbsp;J. R. Prance,&nbsp;X. Rojas,&nbsp;T. Salmon,&nbsp;J. Saunders,&nbsp;J. Smirnov,&nbsp;R. Smith,&nbsp;M. D. Thompson,&nbsp;A. Thomson,&nbsp;A. Ting,&nbsp;V. Tsepelin,&nbsp;S. M. West,&nbsp;L. Whitehead,&nbsp;D. E. Zmeev,&nbsp;QUEST-DMC Collaboration","doi":"10.1007/s10909-026-03364-0","DOIUrl":null,"url":null,"abstract":"<div><p>Superfluid helium-3 bolometers can be utilised for dark matter direct detection searches. The extremely low heat capacity of the B phase of the superfluid helium-3 at ultra-low temperatures offers the potential to reach world leading sensitivity to spin-dependent interactions of dark matter in the sub-GeV/c<span>\\(^2\\)</span> mass range. Here, we describe the development of bolometry using both micron scale and sub-micron diameter vibrating wire resonators, with a SQUID amplifier-based readout scheme. Characterisation of the resonators and bolometer measurements are shown, including the use of nonlinear operation and the corresponding corrections. The bolometer contains two vibrating wire resonators, enabling heat injection calibration and simultaneous bolometer tracking measurements. Coincident events measured on both vibrating wire resonators verify their response. We also demonstrate proof of concept frequency multiplexed readout. Development of these measurement techniques lays the foundations for the use of superfluid helium-3 bolometers, instrumented with vibrating nanomechanical resonators, for future low-threshold dark matter searches.</p></div>","PeriodicalId":641,"journal":{"name":"Journal of Low Temperature Physics","volume":"222 2","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2026-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1007/s10909-026-03364-0.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Low Temperature Physics","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1007/s10909-026-03364-0","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
引用次数: 0

Abstract

Superfluid helium-3 bolometers can be utilised for dark matter direct detection searches. The extremely low heat capacity of the B phase of the superfluid helium-3 at ultra-low temperatures offers the potential to reach world leading sensitivity to spin-dependent interactions of dark matter in the sub-GeV/c\(^2\) mass range. Here, we describe the development of bolometry using both micron scale and sub-micron diameter vibrating wire resonators, with a SQUID amplifier-based readout scheme. Characterisation of the resonators and bolometer measurements are shown, including the use of nonlinear operation and the corresponding corrections. The bolometer contains two vibrating wire resonators, enabling heat injection calibration and simultaneous bolometer tracking measurements. Coincident events measured on both vibrating wire resonators verify their response. We also demonstrate proof of concept frequency multiplexed readout. Development of these measurement techniques lays the foundations for the use of superfluid helium-3 bolometers, instrumented with vibrating nanomechanical resonators, for future low-threshold dark matter searches.

QUEST-DMC实验用SQUID读出纳米线谐振器进行超流氦-3测热
超流体氦-3测热计可用于暗物质直接探测搜索。超流体氦-3的B相在超低温下的极低热容量,为在亚gev /c \(^2\)质量范围内达到世界领先的暗物质自旋依赖相互作用灵敏度提供了可能。在这里,我们描述了使用微米尺度和亚微米直径振动丝谐振器的热测量学的发展,并采用基于SQUID放大器的读出方案。显示了谐振器和测热计的特性,包括非线性操作的使用和相应的校正。热计包含两个振动线谐振器,使热注入校准和同时热计跟踪测量。在两个振动线谐振器上测量的重合事件验证了它们的响应。我们还演示了频率复用读出的概念验证。这些测量技术的发展为超流体氦-3热辐射计的使用奠定了基础,超流体氦-3热辐射计配有振动纳米机械谐振器,用于未来的低阈值暗物质搜索。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Low Temperature Physics
Journal of Low Temperature Physics 物理-物理:凝聚态物理
CiteScore
3.30
自引率
25.00%
发文量
245
审稿时长
1 months
期刊介绍: The Journal of Low Temperature Physics publishes original papers and review articles on all areas of low temperature physics and cryogenics, including theoretical and experimental contributions. Subject areas include: Quantum solids, liquids and gases; Superfluidity; Superconductivity; Condensed matter physics; Experimental techniques; The Journal encourages the submission of Rapid Communications and Special Issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书