{"title":"Influence of Grading and Layer Thickness on Stress Distribution in Dental Ceramics: A Finite Element Analysis.","authors":"Sivaranjani Gali, Srikari Srinivasan","doi":"10.4103/jofs.jofs_265_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Functionally graded designs have been explored in dental ceramics to reduce stress concentrations in layered dental ceramics and enhance their mechanical properties.</p><p><strong>Materials and methods: </strong>Varying wt.% of 3 mol% yttria-stabilized zirconia (20, 35, 50 wt.% YSZ) in fluormica glass systems were processed and their elastic moduli were determined using nano-indentation. A three-layered functionally graded design (20, 35, and 50 wt.% of YSZ in glass for the bottom, middle, and top layer respectively) was designed. The graded designs were further differentiated as layers with uniform and non-uniform thickness. Three-dimensional geometric models of graded, 10-layered functionally graded, bilayered, and monolithic ceramic designs as controls were constructed (ANSYS Version 15.0) for a 2mm thickness of crown over 8 mm of dentin substrate. Plain strain models were built with solid elements (hex8) of element type SOLID 45 of size 0.2mm. Constraints were placed at the inferior border of the substrate with a load of 600 N in the middle of the top layer.</p><p><strong>Results: </strong>Higher maximum principal stress values were observed in 10-layered FGM designs than in bi-layered, monolithic, and experimental designs. In the experimental design, both uniform thickness of 0.6 mm for each layer and non-uniform thickness design combinations showed the least stress values. There was effect of elastic modulus and no significant effect by the uniformity of layers due to similar stress values between the experimental designs.</p><p><strong>Conclusions: </strong>Graded designs irrespective of the layer thickness, dissipate stress and thus, have the potential to reduce structural failures in dental ceramic systems.</p>","PeriodicalId":16651,"journal":{"name":"Journal of Orofacial Sciences","volume":"17 2","pages":"134-149"},"PeriodicalIF":0.0000,"publicationDate":"2025-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7618797/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Orofacial Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jofs.jofs_265_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/21 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Functionally graded designs have been explored in dental ceramics to reduce stress concentrations in layered dental ceramics and enhance their mechanical properties.
Materials and methods: Varying wt.% of 3 mol% yttria-stabilized zirconia (20, 35, 50 wt.% YSZ) in fluormica glass systems were processed and their elastic moduli were determined using nano-indentation. A three-layered functionally graded design (20, 35, and 50 wt.% of YSZ in glass for the bottom, middle, and top layer respectively) was designed. The graded designs were further differentiated as layers with uniform and non-uniform thickness. Three-dimensional geometric models of graded, 10-layered functionally graded, bilayered, and monolithic ceramic designs as controls were constructed (ANSYS Version 15.0) for a 2mm thickness of crown over 8 mm of dentin substrate. Plain strain models were built with solid elements (hex8) of element type SOLID 45 of size 0.2mm. Constraints were placed at the inferior border of the substrate with a load of 600 N in the middle of the top layer.
Results: Higher maximum principal stress values were observed in 10-layered FGM designs than in bi-layered, monolithic, and experimental designs. In the experimental design, both uniform thickness of 0.6 mm for each layer and non-uniform thickness design combinations showed the least stress values. There was effect of elastic modulus and no significant effect by the uniformity of layers due to similar stress values between the experimental designs.
Conclusions: Graded designs irrespective of the layer thickness, dissipate stress and thus, have the potential to reduce structural failures in dental ceramic systems.
期刊介绍:
Journal of Orofacial Sciences is dedicated to noblest profession of Dentistry, and to the young & blossoming intellects of dentistry, with whom the future of dentistry will be cherished better. The prime aim of this journal is to advance the science and art of dentistry. This journal is an educational tool to encourage and share the acquired knowledge with our peers. It also to improves the standards and quality of therauptic methods. This journal assures you to gain knowledge in recent advances and research activities. The journal publishes original scientific papers with special emphasis on research, unusual case reports, editorial, review articles, book reviews & other relevant information in context of high professional standards.