Development of a Phase Transient Test Bench to Optimize a Cold-Atom Microwave Clock

IF 1.8
Luc Archambault;Mathieu Guéridon;Cédric Majek;Luca Lorini;Arnaud Landragin;Bruno Desruelle;Bruno Pelle
{"title":"Development of a Phase Transient Test Bench to Optimize a Cold-Atom Microwave Clock","authors":"Luc Archambault;Mathieu Guéridon;Cédric Majek;Luca Lorini;Arnaud Landragin;Bruno Desruelle;Bruno Pelle","doi":"10.1109/OJUFFC.2026.3664792","DOIUrl":null,"url":null,"abstract":"MuClock is a commercial transportable microwave clock developed at Exail Quantum Systems, using rubidium atoms cooled by isotropic laser light. MuClock is comparable with typical hydrogen masers in terms of volume and long-term frequency stability, as it nominally reaches a fractional frequency stability of <inline-formula> <tex-math>$1\\times 10^{-15}$ </tex-math></inline-formula> in less than two days and maintains this level of performance over more than one month of integration time. The evaluation of several systematic frequency shifts is on-going. This article presents the impact of the frequency bias induced by microwave phase transients on the clock frequency stability and accuracy. Using an in-house designed test bench, the phase of the 6.8 GHz microwave clock signal is measured with a phase resolution close to 1 <inline-formula> <tex-math>$\\mu $ </tex-math></inline-formula>rad and a temporal resolution below 100 ns. It enables a thorough optimization of the sequence and a better control of each phase transient event, making their contributions to the overall frequency shift negligible. Phase peaks induced by electronic components operating in parallel are shifted in time so that their contributions become negligible compared with other frequency uncertainties. The accuracy of the associated systematic effect is evaluated at <inline-formula> <tex-math>$3\\times 10^{-15}$ </tex-math></inline-formula>.","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"6 ","pages":"17-25"},"PeriodicalIF":1.8000,"publicationDate":"2026-02-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11396005","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11396005/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

MuClock is a commercial transportable microwave clock developed at Exail Quantum Systems, using rubidium atoms cooled by isotropic laser light. MuClock is comparable with typical hydrogen masers in terms of volume and long-term frequency stability, as it nominally reaches a fractional frequency stability of $1\times 10^{-15}$ in less than two days and maintains this level of performance over more than one month of integration time. The evaluation of several systematic frequency shifts is on-going. This article presents the impact of the frequency bias induced by microwave phase transients on the clock frequency stability and accuracy. Using an in-house designed test bench, the phase of the 6.8 GHz microwave clock signal is measured with a phase resolution close to 1 $\mu $ rad and a temporal resolution below 100 ns. It enables a thorough optimization of the sequence and a better control of each phase transient event, making their contributions to the overall frequency shift negligible. Phase peaks induced by electronic components operating in parallel are shifted in time so that their contributions become negligible compared with other frequency uncertainties. The accuracy of the associated systematic effect is evaluated at $3\times 10^{-15}$ .
优化冷原子微波时钟的相位瞬变试验台的研制
MuClock是Exail量子系统公司开发的一种商用可移动微波时钟,使用各向同性激光冷却铷原子。MuClock在体积和长期频率稳定性方面可与典型的氢激微波激器相媲美,因为它在不到两天的时间内达到了$1\乘以10^{-15}$的分数频率稳定性,并在一个多月的集成时间内保持这一水平的性能。几个系统频移的评估正在进行中。本文介绍了微波相位瞬变引起的频率偏置对时钟频率稳定性和精度的影响。利用内部设计的测试平台,以接近1 $\mu $ rad的相位分辨率和低于100 ns的时间分辨率测量6.8 GHz微波时钟信号的相位。它可以对序列进行彻底优化,并更好地控制每个相位瞬态事件,使它们对整体频移的贡献可以忽略不计。由并行工作的电子元件引起的相位峰值随时间变化,因此与其他频率不确定性相比,它们的贡献可以忽略不计。相关的系统效应的精度被评估为$3\乘以10^{-15}$。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书