{"title":"Fiber-Guided Red Light-Emitting Diode Localization of an Esophageal Blind End in Long-Gap Esophageal Atresia Surgery: A Case Report.","authors":"Hiroki Kanamori, Tomonori Tsuchiya, Yasuhiro Kondo, Atsuki Naoe, Shunsuke Watanabe, Toshihiro Yasui, Eri Ogawa, Mikihiro Inoue","doi":"10.70352/scrj.cr.25-0543","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Esophageal atresia (EA) Gross type A is a congenital malformation in which both the upper and lower esophagus have blind ends without a tracheoesophageal fistula. The gap between the segments is often long (long-gap EA), making intraoperative localization challenging. We report a case in which the lower esophageal blind end was readily localized using Tumguide (Otsuka Pharmaceutical Factory, Tokushima, Japan), a device that transmits biologically transparent red light from a light-emitting diode (LED) through an optical fiber.</p><p><strong>Case presentation: </strong>The patient was a 2-month-old girl diagnosed at birth with EA Gross type A. A gastrostomy was performed shortly after birth, and esophageal lengthening with the Howard procedure was carried out over the following month. At 2 months of age, she underwent delayed primary esophageal anastomosis. At the start of surgery, the Tumguide was inserted through the gastrostomy site into a Salem Sump gastric drainage tube. The device provided clear localization of the lower esophageal blind end, minimizing the need for dissection of surrounding tissues.</p><p><strong>Conclusions: </strong>Fiber-guided red LED illumination, using Tumguide, enabled safe and straightforward intraoperative localization of the esophageal blind end in long-gap EA Gross type A. This approach minimized the need for dissection, thereby reducing the risks of injury to surrounding tissues and postoperative complications such as anastomotic stricture and leakage.</p>","PeriodicalId":22096,"journal":{"name":"Surgical Case Reports","volume":"12 1","pages":""},"PeriodicalIF":0.7000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12928987/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.70352/scrj.cr.25-0543","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/20 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Esophageal atresia (EA) Gross type A is a congenital malformation in which both the upper and lower esophagus have blind ends without a tracheoesophageal fistula. The gap between the segments is often long (long-gap EA), making intraoperative localization challenging. We report a case in which the lower esophageal blind end was readily localized using Tumguide (Otsuka Pharmaceutical Factory, Tokushima, Japan), a device that transmits biologically transparent red light from a light-emitting diode (LED) through an optical fiber.

Case presentation: The patient was a 2-month-old girl diagnosed at birth with EA Gross type A. A gastrostomy was performed shortly after birth, and esophageal lengthening with the Howard procedure was carried out over the following month. At 2 months of age, she underwent delayed primary esophageal anastomosis. At the start of surgery, the Tumguide was inserted through the gastrostomy site into a Salem Sump gastric drainage tube. The device provided clear localization of the lower esophageal blind end, minimizing the need for dissection of surrounding tissues.

Conclusions: Fiber-guided red LED illumination, using Tumguide, enabled safe and straightforward intraoperative localization of the esophageal blind end in long-gap EA Gross type A. This approach minimized the need for dissection, thereby reducing the risks of injury to surrounding tissues and postoperative complications such as anastomotic stricture and leakage.

光纤引导红光二极管定位长间隙食道闭锁手术中食道盲端1例。
简介:食管闭锁(EA)大体A型是一种先天性畸形,其上食管和下食管均有盲端,无气管食管瘘。节段之间的间隙通常很长(长间隙EA),使得术中定位具有挑战性。我们报告了一例使用Tumguide(日本德岛大冢制药厂)的食管下盲端容易定位的病例,Tumguide是一种通过光纤传输发光二极管(LED)发出的生物透明红光的装置。病例介绍:患者是一名2个月大的女婴,出生时被诊断为EA Gross a型,出生后不久进行了胃造口术,并在接下来的一个月内进行了Howard手术延长食管。在2个月大时,她接受了延迟性食管吻合术。在手术开始时,Tumguide通过胃造口部位插入Salem Sump胃引流管。该装置提供了食管下盲端的清晰定位,最大限度地减少了对周围组织的清扫。结论:在Tumguide的指导下,纤维引导红色LED照明可以安全、直接地在长间隙EA Gross a型食管盲端进行术中定位,减少了解剖的需要,从而降低了对周围组织的损伤和术后吻合口狭窄、瘘等并发症的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
218
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书