Oxidised zirconium heads show a lower linear wear rate than 28-mm metal heads against XLPE: a retrospective analysis.

IF 1.3 4区 医学 Q3 ORTHOPEDICS
HIP International Pub Date : 2026-07-01 Epub Date: 2026-02-25 DOI:10.1177/11207000251412753
Amit Atrey, Zoe Thompson, Veronica Pentland, Richard McCalden, Kevin Gargan, Douglas Naudie, James P Waddell, Graeme Hoite, Amir Khoshbin
{"title":"Oxidised zirconium heads show a lower linear wear rate than 28-mm metal heads against XLPE: a retrospective analysis.","authors":"Amit Atrey, Zoe Thompson, Veronica Pentland, Richard McCalden, Kevin Gargan, Douglas Naudie, James P Waddell, Graeme Hoite, Amir Khoshbin","doi":"10.1177/11207000251412753","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>The use of highly cross-linked polyethylene (XLPE) on the acetabulum has undoubtedly improved the wear rates and hence survivorship of total hip arthroplasty (THA). However, the importance of head tribology is not known. Oxidised zirconium (OxZr) was introduced to offer the lower wear rates of ceramic but the strength of metal. Whether OxZr heads have any purported benefits in terms of lowering wear is not known. This study therefore aims to compare wear rates of XLPE against metal and OxZr heads over a 10-year period.</p><p><strong>Methods: </strong>A previous study has suggested we need a minimum 95 cases to show a statistically significant difference. Thus, in this 10-year retrospective analysis we included 95 subjects with a primary THA with a 28-mm OxZr and 131 patients with a 28-mm cobalt-chrome (CoCr) head, both against XLPE liners.Linear and volumetric wear rate comparisons were performed using a validated 2-dimensional stereoisometric analysis by an independent centre.</p><p><strong>Results: </strong>There were no significant differences for any of the patient demographics between the 2 groups, with >60% women in both groups and normally distributed age. Cup inclination angle was also comparable between the 2 groups.While there was no difference in volumetric wear rates (<i>p</i> = 0.7377), the annual linear wear rate for OxZr was 0.030 mm (95% CI, 0.024-0.036) compared with 0.046 mm (95% CI, 0.038-0.054) for CoCr, a statistically significant difference (<i>p</i> = 0.0002)Conclusions:The widespread use of XLPE has revolutionised THA. This study is the first to show a statistically significantly lower wear rate with the use of OxZr. Whether this is enough to justify the cost differential and whether it translates to better implant survivorship is still to be determined. But if wear limiting wear rates is associated with decreasing revision rates, the use of ceramicised metal may be of clinical benefit.</p>","PeriodicalId":12911,"journal":{"name":"HIP International","volume":" ","pages":"602-608"},"PeriodicalIF":1.3000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13379601/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"HIP International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11207000251412753","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: The use of highly cross-linked polyethylene (XLPE) on the acetabulum has undoubtedly improved the wear rates and hence survivorship of total hip arthroplasty (THA). However, the importance of head tribology is not known. Oxidised zirconium (OxZr) was introduced to offer the lower wear rates of ceramic but the strength of metal. Whether OxZr heads have any purported benefits in terms of lowering wear is not known. This study therefore aims to compare wear rates of XLPE against metal and OxZr heads over a 10-year period.

Methods: A previous study has suggested we need a minimum 95 cases to show a statistically significant difference. Thus, in this 10-year retrospective analysis we included 95 subjects with a primary THA with a 28-mm OxZr and 131 patients with a 28-mm cobalt-chrome (CoCr) head, both against XLPE liners.Linear and volumetric wear rate comparisons were performed using a validated 2-dimensional stereoisometric analysis by an independent centre.

Results: There were no significant differences for any of the patient demographics between the 2 groups, with >60% women in both groups and normally distributed age. Cup inclination angle was also comparable between the 2 groups.While there was no difference in volumetric wear rates (p = 0.7377), the annual linear wear rate for OxZr was 0.030 mm (95% CI, 0.024-0.036) compared with 0.046 mm (95% CI, 0.038-0.054) for CoCr, a statistically significant difference (p = 0.0002)Conclusions:The widespread use of XLPE has revolutionised THA. This study is the first to show a statistically significantly lower wear rate with the use of OxZr. Whether this is enough to justify the cost differential and whether it translates to better implant survivorship is still to be determined. But if wear limiting wear rates is associated with decreasing revision rates, the use of ceramicised metal may be of clinical benefit.

氧化锆头显示较低的线性磨损率比28毫米金属头对XLPE:回顾性分析。
目的:在髋臼上使用高交联聚乙烯(XLPE)无疑提高了全髋关节置换术(THA)的磨损率和生存率。然而,头部摩擦学的重要性尚不为人所知。氧化锆(OxZr)的引入提供了陶瓷的低磨损率,但金属的强度。OxZr头在降低磨损方面是否有任何据称的好处尚不清楚。因此,本研究旨在比较XLPE与金属和氧化锆头在10年期间的磨损率。方法:先前的一项研究表明,我们需要至少95例才能显示统计学上的显著差异。因此,在这项为期10年的回顾性分析中,我们纳入了95例28毫米OxZr的原发性THA患者和131例28毫米钴铬(CoCr)头部患者,均采用XLPE衬套。线性磨损率和体积磨损率的比较使用独立中心验证的二维立体等距分析进行。结果:两组患者的人口统计学差异均无统计学意义,两组患者中女性占60%,年龄呈正态分布。两组间的杯倾角也具有可比性。虽然体积磨损率没有差异(p = 0.7377),但OxZr的年线性磨损率为0.030 mm (95% CI, 0.024-0.036),而CoCr的年线性磨损率为0.046 mm (95% CI, 0.038-0.054),统计学差异(p = 0.0002)。结论:XLPE的广泛使用彻底改变了THA。这项研究首次显示,使用OxZr可以显著降低磨损率。这是否足以证明成本差异的合理性,以及它是否转化为更好的植入物成活率仍有待确定。但是,如果磨损限制磨损率与修正率降低有关,则陶瓷化金属的使用可能具有临床益处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
HIP International
HIP International 医学-整形外科
CiteScore
4.20
自引率
0.00%
发文量
70
审稿时长
2 months
期刊介绍: HIP International is the official journal of the European Hip Society. It is the only international, peer-reviewed, bi-monthly journal dedicated to diseases of the hip. HIP International considers contributions relating to hip surgery, traumatology of the hip, prosthetic surgery, biomechanics, and basic sciences relating to the hip. HIP International invites reviews from leading specialists with the aim of informing its readers of current evidence-based best practice. The journal also publishes supplements containing proceedings of symposia, special meetings or articles of special educational merit. HIP International is divided into six independent sections led by editors of the highest scientific merit. These sections are: • Biomaterials • Biomechanics • Conservative Hip Surgery • Paediatrics • Primary and Revision Hip Arthroplasty • Traumatology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书