{"title":"Organ Dose Assessment in Radiological Central Venous Port Procedures: An Experimental Phantom-Based Study.","authors":"Mehmet Toptaş, Abdurrahman Tünay, Özlem Ateşal, Duygu Tunçman Kayaokay, Fahrettin Fatih Kesmezacar, Osman Günay, Songül Çavdar Karaçam, Didem Çolpan Öksüz, Mustafa Demir, Ghada Al Misned, H O Tekin","doi":"10.1097/HP.0000000000002138","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to quantitatively evaluate radiation doses delivered to radiosensitive thoracic and cervical organs during fluoroscopy-guided central venous port (CVP) catheter placement using a standardized experimental setup to identify the most exposed anatomical regions. An Alderson Rando anthropomorphic phantom equipped with calibrated MTS-100 thermoluminescent dosimeters (TLDs) was employed to simulate a typical CVP fluoroscopic procedure. The setup used a Siemens Artis Zee C-arm fluoroscopy system with a total active exposure time of 8 min, replicating clinical practice. Absorbed dose measurements were obtained from 14 organ sites, including lungs, thyroid, spinal cord, and upper airway structures. The highest radiation doses were observed in thoracic organs, with measured values of 7.84 ± 0.28 mGy for the right middle lung, 5.23 ± 0.40 mGy for the thoracic spinal cord, and 3.91 ± 1.47 mGy for the right lung apex. The thyroid received moderate exposure, recording 1.48 ± 0.35 mGy (right lobe) and 1.41 ± 0.68 mGy (left lobe). In contrast, distant organs such as the pituitary gland and ethmoid sinus exhibited negligible absorbed doses (< 0.03 mGy). Fluoroscopic CVP placement results in substantial localized radiation exposure, particularly to the lungs and thyroid. Quantitative organ dose mapping using an anthropomorphic phantom provides a valuable reference for optimizing patient safety protocols and minimizing radiation exposure during interventional procedures.</p>","PeriodicalId":12976,"journal":{"name":"Health physics","volume":" ","pages":"461-467"},"PeriodicalIF":1.2000,"publicationDate":"2026-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/HP.0000000000002138","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/24 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
This study aimed to quantitatively evaluate radiation doses delivered to radiosensitive thoracic and cervical organs during fluoroscopy-guided central venous port (CVP) catheter placement using a standardized experimental setup to identify the most exposed anatomical regions. An Alderson Rando anthropomorphic phantom equipped with calibrated MTS-100 thermoluminescent dosimeters (TLDs) was employed to simulate a typical CVP fluoroscopic procedure. The setup used a Siemens Artis Zee C-arm fluoroscopy system with a total active exposure time of 8 min, replicating clinical practice. Absorbed dose measurements were obtained from 14 organ sites, including lungs, thyroid, spinal cord, and upper airway structures. The highest radiation doses were observed in thoracic organs, with measured values of 7.84 ± 0.28 mGy for the right middle lung, 5.23 ± 0.40 mGy for the thoracic spinal cord, and 3.91 ± 1.47 mGy for the right lung apex. The thyroid received moderate exposure, recording 1.48 ± 0.35 mGy (right lobe) and 1.41 ± 0.68 mGy (left lobe). In contrast, distant organs such as the pituitary gland and ethmoid sinus exhibited negligible absorbed doses (< 0.03 mGy). Fluoroscopic CVP placement results in substantial localized radiation exposure, particularly to the lungs and thyroid. Quantitative organ dose mapping using an anthropomorphic phantom provides a valuable reference for optimizing patient safety protocols and minimizing radiation exposure during interventional procedures.
期刊介绍:
Health Physics, first published in 1958, provides the latest research to a wide variety of radiation safety professionals including health physicists, nuclear chemists, medical physicists, and radiation safety officers with interests in nuclear and radiation science. The Journal allows professionals in these and other disciplines in science and engineering to stay on the cutting edge of scientific and technological advances in the field of radiation safety. The Journal publishes original papers, technical notes, articles on advances in practical applications, editorials, and correspondence. Journal articles report on the latest findings in theoretical, practical, and applied disciplines of epidemiology and radiation effects, radiation biology and radiation science, radiation ecology, and related fields.