{"title":"Flow and droplet evaporation characteristics of high parameter temperature and pressure reducing valves under off-design conditions","authors":"Heyong Si, Yuqi Ren, Kangning Guo, Honghe Ju, Zhongxiang Tong","doi":"10.1016/j.csite.2026.107855","DOIUrl":null,"url":null,"abstract":"<div><div>The temperature and pressure reducing valve exhibits complex flow, heat, and mass transfer characteristics under off-design conditions. A three-dimensional simulation model of a multi-stage high-temperature and pressure reducing valve (MSHTPRV) was established through the combination of Euler-Lagrange two-phase flow and droplet evaporation models. The temperature and pressure reduction mechanism, as well as the thermal-mass transfer characteristics during droplet evaporation, were investigated. The influence of valve opening on steam flow rate, thermal-mass transfer capabilities, and flow field characteristics was analyzed. The results indicate that the flow rate increases significantly within the 30%–40% opening range and exhibits relatively slow growth in the 60%–100% range. The pressure, temperature, and turbulent kinetic energy inside the valve all decline as the valve opening decreases. When the valve opening is reduced from 100% to 30%, the average pressure inside the valve decreases from 7.65 MPa to 6.88 MPa, and the average temperature drops from 728.29 K to 713.89 K. The mass fraction of newly evaporated steam at the wall above the second-stage throttling orifice plate increases from 0.13 to 0.27, while the turbulent kinetic energy at the right wall of the first-stage throttling orifice plate rises from 4039 m<sup>2</sup>/s<sup>2</sup> to 31,708 m<sup>2</sup>/s<sup>2</sup>. The vortex motion of steam between the first- and second-stage throttling orifice plates intensifies, enhancing the mixing of steam and droplets and accelerating droplet evaporation, thereby improving the cooling effect. After passing through the third-stage throttling orifice plate, both the eddy viscosity and turbulent kinetic energy decrease, reducing heat and mass transfer capabilities. At a valve opening of 50%, the droplet evaporation rate reaches its maximum at 90.9%, but the energy loss due to steam work increases.</div></div>","PeriodicalId":9658,"journal":{"name":"Case Studies in Thermal Engineering","volume":"80 ","pages":"Article 107855"},"PeriodicalIF":6.6000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Studies in Thermal Engineering","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214157X26002170","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/24 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"THERMODYNAMICS","Score":null,"Total":0}
引用次数: 0
Abstract
The temperature and pressure reducing valve exhibits complex flow, heat, and mass transfer characteristics under off-design conditions. A three-dimensional simulation model of a multi-stage high-temperature and pressure reducing valve (MSHTPRV) was established through the combination of Euler-Lagrange two-phase flow and droplet evaporation models. The temperature and pressure reduction mechanism, as well as the thermal-mass transfer characteristics during droplet evaporation, were investigated. The influence of valve opening on steam flow rate, thermal-mass transfer capabilities, and flow field characteristics was analyzed. The results indicate that the flow rate increases significantly within the 30%–40% opening range and exhibits relatively slow growth in the 60%–100% range. The pressure, temperature, and turbulent kinetic energy inside the valve all decline as the valve opening decreases. When the valve opening is reduced from 100% to 30%, the average pressure inside the valve decreases from 7.65 MPa to 6.88 MPa, and the average temperature drops from 728.29 K to 713.89 K. The mass fraction of newly evaporated steam at the wall above the second-stage throttling orifice plate increases from 0.13 to 0.27, while the turbulent kinetic energy at the right wall of the first-stage throttling orifice plate rises from 4039 m2/s2 to 31,708 m2/s2. The vortex motion of steam between the first- and second-stage throttling orifice plates intensifies, enhancing the mixing of steam and droplets and accelerating droplet evaporation, thereby improving the cooling effect. After passing through the third-stage throttling orifice plate, both the eddy viscosity and turbulent kinetic energy decrease, reducing heat and mass transfer capabilities. At a valve opening of 50%, the droplet evaporation rate reaches its maximum at 90.9%, but the energy loss due to steam work increases.
期刊介绍:
Case Studies in Thermal Engineering provides a forum for the rapid publication of short, structured Case Studies in Thermal Engineering and related Short Communications. It provides an essential compendium of case studies for researchers and practitioners in the field of thermal engineering and others who are interested in aspects of thermal engineering cases that could affect other engineering processes. The journal not only publishes new and novel case studies, but also provides a forum for the publication of high quality descriptions of classic thermal engineering problems. The scope of the journal includes case studies of thermal engineering problems in components, devices and systems using existing experimental and numerical techniques in the areas of mechanical, aerospace, chemical, medical, thermal management for electronics, heat exchangers, regeneration, solar thermal energy, thermal storage, building energy conservation, and power generation. Case studies of thermal problems in other areas will also be considered.