{"title":"Looping Stent as a Bailout Manoeuvre Following Carotid Stent Dislocation During Complex Arch Endografting","authors":"Louise Koskas ,&nbsp;Alexandre Oliny ,&nbsp;Stéphan Haulon","doi":"10.1016/j.ejvsvf.2025.12.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Endovascular aortic arch repair using branched devices is an emerging alternative to open surgery in selected high risk patients. Although bridging stent complications are well described during follow up of fenestrated or branched repairs, intra-operative events are still rarely reported.</div></div><div><h3>Report</h3><div>A rare case of intra-operative disconnection of a carotid bridging stent during total endovascular aortic arch repair using a custom made three branch endograft is reported. The complication was caused by guidewire entanglement during challenging catheterisation of a dissected left subclavian artery. Prompt recognition and successful endovascular correction avoided major complications.</div></div><div><h3>Discussion</h3><div>This case highlights a potential pitfall during branched endovascular repair. Awareness of such intra-operative risks is essential to prevent technical failure in this challenging and evolving field.</div></div>","PeriodicalId":36502,"journal":{"name":"EJVES Vascular Forum","volume":"65 ","pages":"Pages 55-57"},"PeriodicalIF":1.8000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJVES Vascular Forum","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666688X25000875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/12/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Endovascular aortic arch repair using branched devices is an emerging alternative to open surgery in selected high risk patients. Although bridging stent complications are well described during follow up of fenestrated or branched repairs, intra-operative events are still rarely reported.

Report

A rare case of intra-operative disconnection of a carotid bridging stent during total endovascular aortic arch repair using a custom made three branch endograft is reported. The complication was caused by guidewire entanglement during challenging catheterisation of a dissected left subclavian artery. Prompt recognition and successful endovascular correction avoided major complications.

Discussion

This case highlights a potential pitfall during branched endovascular repair. Awareness of such intra-operative risks is essential to prevent technical failure in this challenging and evolving field.
环形支架作为复杂弓内移植术中颈动脉支架脱位后的救助操作。
导论:血管内主动脉弓修复使用分支装置是一个新兴的替代开放手术的高风险患者。尽管桥式支架并发症在开窗或分支修复的随访中得到了很好的描述,但术中事件仍然很少报道。报告:在全血管内主动脉弓修复术中,使用定制的三支血管内移植物,发生了一例罕见的颈动脉搭桥支架术中断开的病例。该并发症是由导丝缠绕引起的,在挑战性的左锁骨下动脉夹层置管。及时识别和成功的血管内矫正避免了主要并发症。讨论:本病例强调了分支血管内修复过程中的一个潜在缺陷。在这一具有挑战性和不断发展的领域,了解这种术中风险对于防止技术故障至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
EJVES Vascular Forum
EJVES Vascular Forum Medicine-Surgery
CiteScore
1.50
自引率
0.00%
发文量
145
审稿时长
102 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书