{"title":"Effect of tumor size on motion tracking and dosimetric accuracy using Radixact Synchrony.","authors":"Ryoto Kaido, Akihiro Takemura, Kakeru Sato, Naoki Kinoshita, Kouhei Sasamoto, Tomohiro Kotsuji, Hiroki Shioura, Toshiki Tateishi, Tetsuya Tsujikawa","doi":"10.1093/jrr/rrag002","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to evaluate how planning target volume (PTV) size influences treatment-planning parameters and their relationship to tracking and irradiation accuracy. A high-resolution two-dimensional diode array mounted on a motion phantom was irradiated under four respiratory waveforms using Fiducial Tracking with Respiratory Correlation mode. Spherical PTVs with diameters of 1-4 cm were defined. Treatment-planning parameters, including beam-on time, couch speed, gantry period, kilovoltage imaging interval and modulation factor, were analyzed to assess their relationship with tracking and irradiation accuracy. The root-mean-square error (${\\delta}_{\\mathrm{RMS}}$) between tracked and reference target positions, γ pass rate and potential difference as the control parameter of the correlation model were compared across PTV sizes. Correlation and partial correlation analyses were performed to evaluate the relationships between the ${\\delta}_{\\text{RMS}}$ and treatment-planning parameters. The ${\\delta}_{\\text{RMS}}$ was influenced by the inherent interdependence of beam-on time, gantry period and the kV imaging interval. The kV imaging interval for the PTV of φ1 cm was 4.2 s, longer than those for the other PTV sizes, which made the potential difference unstable during the initial tracking period and kept γ pass rates below 92% across all respiratory waveforms. For the PTVs of φ2-3 cm, potential difference stabilized within ~20 s after beam-on and was associated with an improvement in the γ pass rate. In contrast, for the PTV of φ4 cm, degradation of tracking accuracy was reflected in a reduction in the γ pass rate. Optimizing treatment-planning parameters for each PTV size was essential for precise motion-synchronized irradiation.</p>","PeriodicalId":16922,"journal":{"name":"Journal of Radiation Research","volume":" ","pages":"191-200"},"PeriodicalIF":2.1000,"publicationDate":"2026-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13019149/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiation Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jrr/rrag002","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
This study aimed to evaluate how planning target volume (PTV) size influences treatment-planning parameters and their relationship to tracking and irradiation accuracy. A high-resolution two-dimensional diode array mounted on a motion phantom was irradiated under four respiratory waveforms using Fiducial Tracking with Respiratory Correlation mode. Spherical PTVs with diameters of 1-4 cm were defined. Treatment-planning parameters, including beam-on time, couch speed, gantry period, kilovoltage imaging interval and modulation factor, were analyzed to assess their relationship with tracking and irradiation accuracy. The root-mean-square error (${\delta}_{\mathrm{RMS}}$) between tracked and reference target positions, γ pass rate and potential difference as the control parameter of the correlation model were compared across PTV sizes. Correlation and partial correlation analyses were performed to evaluate the relationships between the ${\delta}_{\text{RMS}}$ and treatment-planning parameters. The ${\delta}_{\text{RMS}}$ was influenced by the inherent interdependence of beam-on time, gantry period and the kV imaging interval. The kV imaging interval for the PTV of φ1 cm was 4.2 s, longer than those for the other PTV sizes, which made the potential difference unstable during the initial tracking period and kept γ pass rates below 92% across all respiratory waveforms. For the PTVs of φ2-3 cm, potential difference stabilized within ~20 s after beam-on and was associated with an improvement in the γ pass rate. In contrast, for the PTV of φ4 cm, degradation of tracking accuracy was reflected in a reduction in the γ pass rate. Optimizing treatment-planning parameters for each PTV size was essential for precise motion-synchronized irradiation.
期刊介绍:
The Journal of Radiation Research (JRR) is an official journal of The Japanese Radiation Research Society (JRRS), and the Japanese Society for Radiation Oncology (JASTRO).
Since its launch in 1960 as the official journal of the JRRS, the journal has published scientific articles in radiation science in biology, chemistry, physics, epidemiology, and environmental sciences. JRR broadened its scope to include oncology in 2009, when JASTRO partnered with the JRRS to publish the journal.
Articles considered fall into two broad categories:
Oncology & Medicine - including all aspects of research with patients that impacts on the treatment of cancer using radiation. Papers which cover related radiation therapies, radiation dosimetry, and those describing the basis for treatment methods including techniques, are also welcomed. Clinical case reports are not acceptable.
Radiation Research - basic science studies of radiation effects on livings in the area of physics, chemistry, biology, epidemiology and environmental sciences.
Please be advised that JRR does not accept any papers of pure physics or chemistry.