Wavefront Automated Refraction Comparison of Three Different IOLs: Aspheric Monofocal and Two Enhanced Monofocal IOLs.

IF 1.8 Q2 Medicine
Arthur Buffara van den Berg, Roberta Matschinske van den Berg, Bernardo Kaplan Moscovici, Maya Dodhia, Larissa Gouvea, Wallace Chamon, Karolinne Maia Rocha
{"title":"Wavefront Automated Refraction Comparison of Three Different IOLs: Aspheric Monofocal and Two Enhanced Monofocal IOLs.","authors":"Arthur Buffara van den Berg, Roberta Matschinske van den Berg, Bernardo Kaplan Moscovici, Maya Dodhia, Larissa Gouvea, Wallace Chamon, Karolinne Maia Rocha","doi":"10.3390/vision10010006","DOIUrl":null,"url":null,"abstract":"<p><p>The objective of this study was to compare subjective manifest refraction with wavefront-based automated refraction using iTrace (ray tracing) and LadarWave (Hartmann-Shack) in eyes implanted with two enhanced monofocal intraocular lenses (IOLs) and a standard aspheric monofocal IOL, emphasizing agreement and refractive variability across optical designs. This retrospective cohort included 84 eyes from 42 patients implanted with Tecnis Eyhance (DIB00), RayOne EMV (RAO200E), or Tecnis ZCB00 IOLs. Postoperative evaluation (1-3 months) included uncorrected and corrected distance visual acuity and subjective manifest refraction, followed by automated refraction with iTrace and LadarWave. Outcomes were sphere, cylinder, and spherical equivalent (SE). Agreement was assessed using mean signed difference, mean absolute error, root mean square error, Bland-Altman limits of agreement, proportions within clinically relevant thresholds, and vector astigmatism (J0, J45). Linear mixed-effect modeling evaluated SE differences across methods and IOL types while accounting for within-subject correlation. Subjective SE differed among IOLs (<i>p</i> = 0.027), with RAO200E more myopic than ZCB00 (-0.20 ± 0.32 D vs. -0.08 ± 0.44 D, <i>p</i> = 0.035). Automated refraction showed greater variability and poorer agreement in enhanced monofocal IOLs, particularly for cylinder and SE, with wider limits of agreement and fewer eyes within ±0.50 D compared with ZCB00. In mixed-effect contrasts (three-method repeated-measures model), iTrace and LadarWave showed a consistent myopic bias versus manifest refraction in DIB00 and RAO200E, whereas in ZCB00 the iTrace-manifest difference was not significant and LadarWave retained a significant myopic bias. Enhanced monofocal IOLs exhibit reduced agreement between wavefront-based automated and subjective manifest refraction compared with a standard aspheric monofocal IOL. Manifest refraction remains essential for postoperative assessment, and automated measurements should be interpreted as complementary, particularly in IOL designs that modify aberrations.</p>","PeriodicalId":36586,"journal":{"name":"Vision (Switzerland)","volume":"10 1","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2026-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12921915/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Vision (Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/vision10010006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

The objective of this study was to compare subjective manifest refraction with wavefront-based automated refraction using iTrace (ray tracing) and LadarWave (Hartmann-Shack) in eyes implanted with two enhanced monofocal intraocular lenses (IOLs) and a standard aspheric monofocal IOL, emphasizing agreement and refractive variability across optical designs. This retrospective cohort included 84 eyes from 42 patients implanted with Tecnis Eyhance (DIB00), RayOne EMV (RAO200E), or Tecnis ZCB00 IOLs. Postoperative evaluation (1-3 months) included uncorrected and corrected distance visual acuity and subjective manifest refraction, followed by automated refraction with iTrace and LadarWave. Outcomes were sphere, cylinder, and spherical equivalent (SE). Agreement was assessed using mean signed difference, mean absolute error, root mean square error, Bland-Altman limits of agreement, proportions within clinically relevant thresholds, and vector astigmatism (J0, J45). Linear mixed-effect modeling evaluated SE differences across methods and IOL types while accounting for within-subject correlation. Subjective SE differed among IOLs (p = 0.027), with RAO200E more myopic than ZCB00 (-0.20 ± 0.32 D vs. -0.08 ± 0.44 D, p = 0.035). Automated refraction showed greater variability and poorer agreement in enhanced monofocal IOLs, particularly for cylinder and SE, with wider limits of agreement and fewer eyes within ±0.50 D compared with ZCB00. In mixed-effect contrasts (three-method repeated-measures model), iTrace and LadarWave showed a consistent myopic bias versus manifest refraction in DIB00 and RAO200E, whereas in ZCB00 the iTrace-manifest difference was not significant and LadarWave retained a significant myopic bias. Enhanced monofocal IOLs exhibit reduced agreement between wavefront-based automated and subjective manifest refraction compared with a standard aspheric monofocal IOL. Manifest refraction remains essential for postoperative assessment, and automated measurements should be interpreted as complementary, particularly in IOL designs that modify aberrations.

三种不同人工晶体的波前自动折射比较:非球面单焦点和两种增强单焦点人工晶体。
本研究的目的是比较使用iTrace(光线追踪)和LadarWave (Hartmann-Shack)技术在植入两个增强单焦点人工晶状体(IOL)和一个标准非球面单焦点人工晶状体的眼睛中主观明显折射和基于波前的自动折射,强调不同光学设计的一致性和屈光变异性。本回顾性队列包括42例植入Tecnis Eyhance (DIB00)、RayOne EMV (RAO200E)或Tecnis ZCB00人工晶状体患者的84只眼。术后评估(1-3个月)包括未矫正和矫正的距离视力和主观明显屈光,随后使用iTrace和LadarWave进行自动屈光检查。结果为球体、圆柱体和球体等效(SE)。使用平均符号差、平均绝对误差、均方根误差、Bland-Altman一致限、临床相关阈值内的比例和矢量散光来评估一致性(J0, J45)。线性混合效应模型评估了不同方法和IOL类型的SE差异,同时考虑了受试者内部的相关性。不同人工晶状体的主观SE差异(p = 0.027), RAO200E比ZCB00更近视(-0.20±0.32 D比-0.08±0.44 D, p = 0.035)。与ZCB00相比,增强单焦点iol的自动折射变异性更大,一致性更差,尤其是圆柱体和SE,一致性范围更广,±0.50 D内的眼睛更少。在混合效应对比(三种方法重复测量模型)中,iTrace和LadarWave在DIB00和RAO200E中显示出一致的近视偏倚与明显屈光,而在ZCB00中iTrace-manifest差异不显著,LadarWave保留了显著的近视偏倚。与标准非球面单焦点IOL相比,增强单焦点IOL表现出基于波前的自动和主观明显折射之间的一致性降低。明显的屈光仍然是术后评估的必要条件,自动测量应被解释为补充,特别是在人工晶状体设计修改像差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Vision (Switzerland)
Vision (Switzerland) Health Professions-Optometry
CiteScore
2.30
自引率
0.00%
发文量
62
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书