Divya Dileep, Kiran Bali, Sabrina Soares, Martin Schmelz, Roman Rukwied
{"title":"Optimum electrical sinusoidal frequency stimulation to activate C-nociceptors.","authors":"Divya Dileep, Kiran Bali, Sabrina Soares, Martin Schmelz, Roman Rukwied","doi":"10.1097/PR9.0000000000001412","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Electrical sinusoidal stimulation has been shown to reliably activate C-fibers. Here, we explored the optimum sinusoidal frequency for C-nociceptor responses.</p><p><strong>Objectives: </strong>Identify the optimum sinusoidal frequency to activate single C-nociceptors in pigs and to provoke pain and axon reflex flare in humans.</p><p><strong>Methods: </strong>Single C-fibers (n = 60) were recorded from pig saphenous nerves in vivo in response to transcutaneous sinusoidal electrical stimulation delivered at frequencies of 3 to 100 Hz with increasing amplitudes. In 22 human subjects, 30 sinusoidal pulses were delivered with 3 to 20 Hz at 0.0125 to 0.4 mA amplitudes and perception thresholds, evoked pain (numeric rating scale, 0-10) and axon reflex flare (full-field laser perfusion imaging) were monitored in 4 seconds intervals.</p><p><strong>Results: </strong>Single C-nociceptors (36 \"polymodal\" [C-mechano-heat-sensitive], 15 \"very high threshold, and 9 \"silent\" [C-mechano-insensitive]) were activated more easily at frequencies below 8 Hz as compared with frequencies >10 Hz. In humans, pain and flare responses were also found to be frequency dependent. Pain threshold assessments were particularly sensitive at a frequency of 4 Hz. Highest pain ratings were recorded from 3 to 6 Hz at stimulation amplitudes of 0.2 mA. Significant axon reflex flare responses developed at low amplitudes of 0.05 and 0.1 mA at frequencies of 4 and 8 Hz only.</p><p><strong>Conclusion: </strong>Sinusoidal frequencies between 3 and 8 Hz are better suited to activate C-nociceptors than stimuli above 10 Hz and are expected to facilitate C-nociceptor recruitment for their functional assessment in volunteers and chronic pain patients.</p>","PeriodicalId":52189,"journal":{"name":"Pain Reports","volume":"11 2","pages":"e1412"},"PeriodicalIF":4.3000,"publicationDate":"2026-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12915732/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pain Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/PR9.0000000000001412","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Electrical sinusoidal stimulation has been shown to reliably activate C-fibers. Here, we explored the optimum sinusoidal frequency for C-nociceptor responses.
Objectives: Identify the optimum sinusoidal frequency to activate single C-nociceptors in pigs and to provoke pain and axon reflex flare in humans.
Methods: Single C-fibers (n = 60) were recorded from pig saphenous nerves in vivo in response to transcutaneous sinusoidal electrical stimulation delivered at frequencies of 3 to 100 Hz with increasing amplitudes. In 22 human subjects, 30 sinusoidal pulses were delivered with 3 to 20 Hz at 0.0125 to 0.4 mA amplitudes and perception thresholds, evoked pain (numeric rating scale, 0-10) and axon reflex flare (full-field laser perfusion imaging) were monitored in 4 seconds intervals.
Results: Single C-nociceptors (36 "polymodal" [C-mechano-heat-sensitive], 15 "very high threshold, and 9 "silent" [C-mechano-insensitive]) were activated more easily at frequencies below 8 Hz as compared with frequencies >10 Hz. In humans, pain and flare responses were also found to be frequency dependent. Pain threshold assessments were particularly sensitive at a frequency of 4 Hz. Highest pain ratings were recorded from 3 to 6 Hz at stimulation amplitudes of 0.2 mA. Significant axon reflex flare responses developed at low amplitudes of 0.05 and 0.1 mA at frequencies of 4 and 8 Hz only.
Conclusion: Sinusoidal frequencies between 3 and 8 Hz are better suited to activate C-nociceptors than stimuli above 10 Hz and are expected to facilitate C-nociceptor recruitment for their functional assessment in volunteers and chronic pain patients.