R. Li , D. Verney , C. Delafosse , M.N. Harakeh , A. Maj , F. Didierjean , L. Al Ayoubi , H. Al Falou , P. Bednarczyk , G. Benzoni , F. Le Blanc , V. Bozkurt , M. Ciemała , F.C.L. Crespi , I. Deloncle , C. Gaulard , A. Gottardo , V. Guadilla , J. Guillot , K. Hadyńska-Klęk , G. Tocabens
{"title":"Data sorting modes of phoswich detector array","authors":"R. Li , D. Verney , C. Delafosse , M.N. Harakeh , A. Maj , F. Didierjean , L. Al Ayoubi , H. Al Falou , P. Bednarczyk , G. Benzoni , F. Le Blanc , V. Bozkurt , M. Ciemała , F.C.L. Crespi , I. Deloncle , C. Gaulard , A. Gottardo , V. Guadilla , J. Guillot , K. Hadyńska-Klęk , G. Tocabens","doi":"10.1016/j.nima.2026.171337","DOIUrl":null,"url":null,"abstract":"<div><div>The different data-sorting modes of the phoswich detector array PARIS used for detecting high-energy (4<span><math><mo>−</mo></math></span>10 MeV) <span><math><mi>γ</mi></math></span> rays are investigated. The characteristics including time resolution, energy resolution and detection efficiency under various modes are studied. The present study shows that PARIS has capabilities of rejecting escape and pileup events when used for decay spectroscopy. Notably, the methods presented in this work refer specifically to the <span><math><mi>β</mi></math></span>-decay experiment of <span><math><msup><mrow></mrow><mrow><mn>80</mn><mi>g</mi><mo>+</mo><mi>m</mi></mrow></msup></math></span>Ga conducted with three PARIS clusters comprising 27 phoswich detectors, rather than to a general report on the PARIS array or its overall performance for in-beam spectroscopy. Compared with the 2”<span><math><mo>×</mo></math></span>2”<span><math><mo>×</mo></math></span>2” LaBr<span><math><msub><mrow></mrow><mrow><mn>3</mn></mrow></msub></math></span>(Ce) detector (Ciemała et al., 2009), even in individual mode, PARIS provides significant suppression of single- and double-escape peaks and reduces background via vetoing function of the outer-volume NaI(Tl) crystals. In contrast to the common approach of adding back the energies in LaBr<span><math><msub><mrow></mrow><mrow><mn>3</mn></mrow></msub></math></span>(Ce) and NaI(Tl) to increase the detection efficiency of the full-energy peak, using NaI(Tl) as a veto shield provides a superior trade-off for applications where spectral purity is essential. Employing add-back analysis within each cluster of nine phoswiches or between all phoswiches could enhance full-energy peak efficiency and further suppress escape peaks and background. Applying a multiplicity condition provides a further suppression but simultaneously lowers the statistics of full-energy peaks.</div></div>","PeriodicalId":19359,"journal":{"name":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","volume":"1086 ","pages":"Article 171337"},"PeriodicalIF":1.5000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S016890022600063X","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
The different data-sorting modes of the phoswich detector array PARIS used for detecting high-energy (410 MeV) rays are investigated. The characteristics including time resolution, energy resolution and detection efficiency under various modes are studied. The present study shows that PARIS has capabilities of rejecting escape and pileup events when used for decay spectroscopy. Notably, the methods presented in this work refer specifically to the -decay experiment of Ga conducted with three PARIS clusters comprising 27 phoswich detectors, rather than to a general report on the PARIS array or its overall performance for in-beam spectroscopy. Compared with the 2”2”2” LaBr(Ce) detector (Ciemała et al., 2009), even in individual mode, PARIS provides significant suppression of single- and double-escape peaks and reduces background via vetoing function of the outer-volume NaI(Tl) crystals. In contrast to the common approach of adding back the energies in LaBr(Ce) and NaI(Tl) to increase the detection efficiency of the full-energy peak, using NaI(Tl) as a veto shield provides a superior trade-off for applications where spectral purity is essential. Employing add-back analysis within each cluster of nine phoswiches or between all phoswiches could enhance full-energy peak efficiency and further suppress escape peaks and background. Applying a multiplicity condition provides a further suppression but simultaneously lowers the statistics of full-energy peaks.
期刊介绍:
Section A of Nuclear Instruments and Methods in Physics Research publishes papers on design, manufacturing and performance of scientific instruments with an emphasis on large scale facilities. This includes the development of particle accelerators, ion sources, beam transport systems and target arrangements as well as the use of secondary phenomena such as synchrotron radiation and free electron lasers. It also includes all types of instrumentation for the detection and spectrometry of radiations from high energy processes and nuclear decays, as well as instrumentation for experiments at nuclear reactors. Specialized electronics for nuclear and other types of spectrometry as well as computerization of measurements and control systems in this area also find their place in the A section.
Theoretical as well as experimental papers are accepted.