{"title":"Influence mechanism on thermoelectric and refrigerating performance of PVT composite cycle system with collaborative compressor-refrigerant pump drive","authors":"Xiaochao Guo , Yiping Wu , Boyuan Wang , Qingpeng Wei","doi":"10.1016/j.renene.2026.125350","DOIUrl":null,"url":null,"abstract":"<div><div>The lack of clarity regarding the quantitative influence mechanisms poses a significant challenge to the optimized design and reliable application of the novel PVT composite cycle system with collaborative compressor-refrigerant pump drive in different regions. Therefore, a simulation platform was established to investigate the mechanism that influences the thermoelectric and refrigerating performance of the novel system. The research indicates that for every 1.0 °C increase in ambient temperature, the heating <em>COP</em> rises by 1.5 %, 5.0 %, and 5.0 % for the PVT heat pump, PVT composite cycle, and PVT power heat pipe cogeneration modes, respectively, while the exergy efficiency decreases by 0.5 % across all modes; with every 10 W/m<sup>2</sup> increase in solar irradiance, the heating <em>COP</em> increases by 1.5 %, 3.0 %, and 2.0 % for the previously mentioned three cogeneration modes, respectively, and the exergy efficiency sees a 0.1 % increase across all modes. Moreover, with each 1.0 °C rise in ambient temperature, the refrigerating capacity and refrigerating <em>COP</em> decrease by 1.5 % and 2.5 %, respectively; for each 1 m/s escalation in wind speed, the refrigerating capacity and refrigerating <em>COP</em> are enhanced by 3.0 % and 5.0 %, respectively. The heating <em>COP</em> and exergy efficiency of the proposed system are, respectively, 10.0 %–575 % and 5.0 %–25.0 % superior to those of the existing PVT heat pump system. Furthermore, the additional investment relative to the existing PVT heat pump system is projected to be recouped within a span of 0.6–2.0 years. These findings provide a crucial theoretical framework and definitive performance benchmarks for the optimized design and application of this novel system across diverse climatic regions.</div></div>","PeriodicalId":419,"journal":{"name":"Renewable Energy","volume":"262 ","pages":"Article 125350"},"PeriodicalIF":9.1000,"publicationDate":"2026-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Renewable Energy","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0960148126001758","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
The lack of clarity regarding the quantitative influence mechanisms poses a significant challenge to the optimized design and reliable application of the novel PVT composite cycle system with collaborative compressor-refrigerant pump drive in different regions. Therefore, a simulation platform was established to investigate the mechanism that influences the thermoelectric and refrigerating performance of the novel system. The research indicates that for every 1.0 °C increase in ambient temperature, the heating COP rises by 1.5 %, 5.0 %, and 5.0 % for the PVT heat pump, PVT composite cycle, and PVT power heat pipe cogeneration modes, respectively, while the exergy efficiency decreases by 0.5 % across all modes; with every 10 W/m2 increase in solar irradiance, the heating COP increases by 1.5 %, 3.0 %, and 2.0 % for the previously mentioned three cogeneration modes, respectively, and the exergy efficiency sees a 0.1 % increase across all modes. Moreover, with each 1.0 °C rise in ambient temperature, the refrigerating capacity and refrigerating COP decrease by 1.5 % and 2.5 %, respectively; for each 1 m/s escalation in wind speed, the refrigerating capacity and refrigerating COP are enhanced by 3.0 % and 5.0 %, respectively. The heating COP and exergy efficiency of the proposed system are, respectively, 10.0 %–575 % and 5.0 %–25.0 % superior to those of the existing PVT heat pump system. Furthermore, the additional investment relative to the existing PVT heat pump system is projected to be recouped within a span of 0.6–2.0 years. These findings provide a crucial theoretical framework and definitive performance benchmarks for the optimized design and application of this novel system across diverse climatic regions.
期刊介绍:
Renewable Energy journal is dedicated to advancing knowledge and disseminating insights on various topics and technologies within renewable energy systems and components. Our mission is to support researchers, engineers, economists, manufacturers, NGOs, associations, and societies in staying updated on new developments in their respective fields and applying alternative energy solutions to current practices.
As an international, multidisciplinary journal in renewable energy engineering and research, we strive to be a premier peer-reviewed platform and a trusted source of original research and reviews in the field of renewable energy. Join us in our endeavor to drive innovation and progress in sustainable energy solutions.