BiFeO3 perovskite/reduced graphene oxide nanocomposite as a novel modifier for electrochemical detection of dopamine in real samples

IF 4.7 Q1 CHEMISTRY, ANALYTICAL
Sensing and Bio-Sensing Research Pub Date : 2026-02-01 Epub Date: 2026-02-11 DOI:10.1016/j.sbsr.2026.100978
Masoumeh Ranjbarzadhag , Biuck Habibi , Mohammad Reza Rashidi , Balal Khalilzadeh , Abdolali Alami
{"title":"BiFeO3 perovskite/reduced graphene oxide nanocomposite as a novel modifier for electrochemical detection of dopamine in real samples","authors":"Masoumeh Ranjbarzadhag ,&nbsp;Biuck Habibi ,&nbsp;Mohammad Reza Rashidi ,&nbsp;Balal Khalilzadeh ,&nbsp;Abdolali Alami","doi":"10.1016/j.sbsr.2026.100978","DOIUrl":null,"url":null,"abstract":"<div><div>Dopamine (DA) is a fundamental catecholamine neurotransmitter and fluctuating its concentration level in human body may leads to neurodegeneration. Therefore, it is important to assess the DA levels in human biological fluids. This project studied the preparation of a novel nanocomposite containing BiFeO<sub>3</sub> perovskite nanoparticles and reduced graphene oxide (rGO) by hydrothermal methodology and its application as a modifier for the fabrication of modified glassy carbon electrode; BiFeO<sub>3</sub>-rGO/GCE, toward the detection of DA in real samples. The physicochemical characterizations of prepared materials and modified electrode were examined by scanning electron microscopy, energy-dispersive X-ray spectrometry, transmission electron microscopy, X-ray diffraction, Raman and Fourier-transform infrared spectrometry, and electrochemical methods. The electrochemical investigations indicated that the BiFeO<sub>3</sub>-rGO greatly improved the electrocatalytic activity of modified electrode toward the DA oxidation, thereby improving sensing performance. The BiFeO<sub>3</sub>-rGO/GCE was used as a sensor for detection of DA by differential pulse voltammetry. The developed sensor in the optimum conditions showed two dynamic linear ranges of 1–100 μM and 100–1000 μM with limits of detection as 0.35 μM. The sensor also exhibited high selectivity, sensitivity, reproducibility and stability. Finally, the prepared sensor was utilized for electrochemical detection of DA in real samples with acceptable results (average recovery&gt;97%) and compared with the commercial immunosorbent test (ELISA).</div></div>","PeriodicalId":424,"journal":{"name":"Sensing and Bio-Sensing Research","volume":"51 ","pages":"Article 100978"},"PeriodicalIF":4.7000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensing and Bio-Sensing Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214180426000280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/11 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Dopamine (DA) is a fundamental catecholamine neurotransmitter and fluctuating its concentration level in human body may leads to neurodegeneration. Therefore, it is important to assess the DA levels in human biological fluids. This project studied the preparation of a novel nanocomposite containing BiFeO3 perovskite nanoparticles and reduced graphene oxide (rGO) by hydrothermal methodology and its application as a modifier for the fabrication of modified glassy carbon electrode; BiFeO3-rGO/GCE, toward the detection of DA in real samples. The physicochemical characterizations of prepared materials and modified electrode were examined by scanning electron microscopy, energy-dispersive X-ray spectrometry, transmission electron microscopy, X-ray diffraction, Raman and Fourier-transform infrared spectrometry, and electrochemical methods. The electrochemical investigations indicated that the BiFeO3-rGO greatly improved the electrocatalytic activity of modified electrode toward the DA oxidation, thereby improving sensing performance. The BiFeO3-rGO/GCE was used as a sensor for detection of DA by differential pulse voltammetry. The developed sensor in the optimum conditions showed two dynamic linear ranges of 1–100 μM and 100–1000 μM with limits of detection as 0.35 μM. The sensor also exhibited high selectivity, sensitivity, reproducibility and stability. Finally, the prepared sensor was utilized for electrochemical detection of DA in real samples with acceptable results (average recovery>97%) and compared with the commercial immunosorbent test (ELISA).
BiFeO3钙钛矿/还原性氧化石墨烯纳米复合材料作为一种新的电化学检测多巴胺的改性剂
多巴胺(DA)是一种基本的儿茶酚胺类神经递质,其浓度在人体内的波动可能导致神经退行性变。因此,评估人体生物体液中的DA水平是很重要的。本课题研究了水热法制备含BiFeO3钙钛矿纳米粒子和还原性氧化石墨烯(rGO)的新型纳米复合材料及其作为改性玻碳电极的改性剂的应用;BiFeO3-rGO/GCE,用于实际样品中DA的检测。采用扫描电镜、能量色散x射线光谱、透射电镜、x射线衍射、拉曼和傅里叶变换红外光谱以及电化学方法对制备的材料和修饰电极进行了理化表征。电化学研究表明,BiFeO3-rGO大大提高了修饰电极对DA氧化的电催化活性,从而提高了传感性能。采用BiFeO3-rGO/GCE作为传感器,采用差分脉冲伏安法检测DA。在最优条件下,传感器的动态线性范围为1 ~ 100 μM和100 ~ 1000 μM,检测限为0.35 μM。该传感器具有较高的选择性、灵敏度、重复性和稳定性。最后,将所制备的传感器用于实际样品中DA的电化学检测,结果可接受(平均回收率>;97%),并与商业免疫吸附试验(ELISA)进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sensing and Bio-Sensing Research
Sensing and Bio-Sensing Research Engineering-Electrical and Electronic Engineering
CiteScore
10.70
自引率
3.80%
发文量
68
审稿时长
87 days
期刊介绍: Sensing and Bio-Sensing Research is an open access journal dedicated to the research, design, development, and application of bio-sensing and sensing technologies. The editors will accept research papers, reviews, field trials, and validation studies that are of significant relevance. These submissions should describe new concepts, enhance understanding of the field, or offer insights into the practical application, manufacturing, and commercialization of bio-sensing and sensing technologies. The journal covers a wide range of topics, including sensing principles and mechanisms, new materials development for transducers and recognition components, fabrication technology, and various types of sensors such as optical, electrochemical, mass-sensitive, gas, biosensors, and more. It also includes environmental, process control, and biomedical applications, signal processing, chemometrics, optoelectronic, mechanical, thermal, and magnetic sensors, as well as interface electronics. Additionally, it covers sensor systems and applications, µTAS (Micro Total Analysis Systems), development of solid-state devices for transducing physical signals, and analytical devices incorporating biological materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书