Noise-reduced optical detection of miRNA-155 by porous silicon through Morlet wavelet phase analysis

IF 10.61 Q3 Biochemistry, Genetics and Molecular Biology
Biosensors and Bioelectronics: X Pub Date : 2026-05-01 Epub Date: 2026-02-04 DOI:10.1016/j.biosx.2026.100752
Filiz Karakuş Başak
{"title":"Noise-reduced optical detection of miRNA-155 by porous silicon through Morlet wavelet phase analysis","authors":"Filiz Karakuş Başak","doi":"10.1016/j.biosx.2026.100752","DOIUrl":null,"url":null,"abstract":"<div><div>Porous silicon (pSi) reflectance-based optical biosensors are highly promising platforms for miRNA detection. However, reliable detection of very small effective optical thickness changes associated with miRNA binding remains challenging using conventional Reflective Interferometric Fourier Transform Spectroscopy (RIFTS). In this work, a reflectometric pSi thin-film biosensor was developed for miRNA-155 detection, and complex Morlet wavelet phase analysis (MWPA) was applied, for the first time in miRNA sensing, to suppress spectral noise in the reflectance spectra of the pSi thin film. Using MWPA, small optical thickness changes were detected with high confidence in phosphate-buffered saline (PBS), yielding an ultralow LOD of approximately 0.13 pM. In contrast, detectable changes were observed in only 28% of the data when RIFTS was used, and the LOD was estimated at approximately 0.72 pM from data with poor reliability. High selectivity against mismatched miRNA-148 was also achieved. These results demonstrate the superiority of MWPA over RIFTS for the analysis of reflectance spectra from pSi nanostructures optimized for miRNA detection, providing a reliable and sensitive platform for label-free optical biosensing of miRNA.</div></div>","PeriodicalId":260,"journal":{"name":"Biosensors and Bioelectronics: X","volume":"29 ","pages":"Article 100752"},"PeriodicalIF":10.6100,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590137026000178","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

Porous silicon (pSi) reflectance-based optical biosensors are highly promising platforms for miRNA detection. However, reliable detection of very small effective optical thickness changes associated with miRNA binding remains challenging using conventional Reflective Interferometric Fourier Transform Spectroscopy (RIFTS). In this work, a reflectometric pSi thin-film biosensor was developed for miRNA-155 detection, and complex Morlet wavelet phase analysis (MWPA) was applied, for the first time in miRNA sensing, to suppress spectral noise in the reflectance spectra of the pSi thin film. Using MWPA, small optical thickness changes were detected with high confidence in phosphate-buffered saline (PBS), yielding an ultralow LOD of approximately 0.13 pM. In contrast, detectable changes were observed in only 28% of the data when RIFTS was used, and the LOD was estimated at approximately 0.72 pM from data with poor reliability. High selectivity against mismatched miRNA-148 was also achieved. These results demonstrate the superiority of MWPA over RIFTS for the analysis of reflectance spectra from pSi nanostructures optimized for miRNA detection, providing a reliable and sensitive platform for label-free optical biosensing of miRNA.
基于Morlet小波相位分析的多孔硅miRNA-155的降噪光学检测
基于多孔硅(pSi)反射的光学生物传感器是非常有前途的miRNA检测平台。然而,使用传统的反射干涉傅立叶变换光谱(RIFTS)可靠地检测与miRNA结合相关的非常小的有效光学厚度变化仍然具有挑战性。本文开发了一种用于miRNA-155检测的反射式pSi薄膜生物传感器,并首次在miRNA检测中应用了复Morlet小波相位分析(complex Morlet wavelet phase analysis, MWPA)来抑制pSi薄膜反射光谱中的光谱噪声。使用MWPA,可以在磷酸盐缓冲盐水(PBS)中以高置信度检测到微小的光学厚度变化,产生约0.13 pM的超低LOD。相比之下,当使用RIFTS时,仅在28%的数据中观察到可检测的变化,并且从可靠性较差的数据中估计LOD约为0.72 pM。对错配的miRNA-148也实现了高选择性。这些结果证明了MWPA在分析pSi纳米结构的反射光谱方面优于RIFTS,为miRNA的无标记光学生物传感提供了可靠、灵敏的平台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biosensors and Bioelectronics: X
Biosensors and Bioelectronics: X Biochemistry, Genetics and Molecular Biology-Biophysics
CiteScore
4.60
自引率
0.00%
发文量
166
审稿时长
54 days
期刊介绍: Biosensors and Bioelectronics: X, an open-access companion journal of Biosensors and Bioelectronics, boasts a 2020 Impact Factor of 10.61 (Journal Citation Reports, Clarivate Analytics 2021). Offering authors the opportunity to share their innovative work freely and globally, Biosensors and Bioelectronics: X aims to be a timely and permanent source of information. The journal publishes original research papers, review articles, communications, editorial highlights, perspectives, opinions, and commentaries at the intersection of technological advancements and high-impact applications. Manuscripts submitted to Biosensors and Bioelectronics: X are assessed based on originality and innovation in technology development or applications, aligning with the journal's goal to cater to a broad audience interested in this dynamic field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书