A new modified low chattering fast terminal sliding mode control for non-isolated minimum-phase power converter

IF 6.6 2区 计算机科学 Q1 AUTOMATION & CONTROL SYSTEMS
ISA transactions Pub Date : 2026-03-01 Epub Date: 2026-01-31 DOI:10.1016/j.isatra.2026.01.043
Güven Balta , Cagdas Hisar , Necmi Altin , Ibrahim Sefa
{"title":"A new modified low chattering fast terminal sliding mode control for non-isolated minimum-phase power converter","authors":"Güven Balta ,&nbsp;Cagdas Hisar ,&nbsp;Necmi Altin ,&nbsp;Ibrahim Sefa","doi":"10.1016/j.isatra.2026.01.043","DOIUrl":null,"url":null,"abstract":"<div><div>Through modification of the strongest global fast terminal sliding mode control (GFTSMC) previously reported in the literature, a new sliding surface is proposed in this paper. Among all the FTSMC structures evaluated so far, the new surface exhibits the least chattering and the best error convergence trajectory with the addition of the logarithmic expression. The effectiveness of the low chattering GFTSMC (LCGFTSMC) is demonstrated on the non-isolated minimum-phase DC-DC power converter known as the Buck converter based on the direct SMC theory. In the direct SMC, hysteresis modulation (HM), which results in a fluctuating switching frequency, is replaced by parabolic modulation (PM), which offers a constant switching frequency. Dynamic results are obtained and compared for both modulations, taking into consideration one of the factors that cause the system’s switching frequency to fluctuate. Furthermore, and most importantly, the PM approach is compared to one of the techniques presented in the literature for fixed switching frequency, which is another significant part of this study. Because the closed loops offered for fixed switching frequencies have never been compared to each other prior to this work. A series of simulation and experimental tests have been carried out on the new sliding surface and the PM, and the results show that both provide remarkable dynamic responses compared to their counterparts.</div></div>","PeriodicalId":14660,"journal":{"name":"ISA transactions","volume":"170 ","pages":"Pages 274-287"},"PeriodicalIF":6.6000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISA transactions","FirstCategoryId":"94","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0019057826000571","RegionNum":2,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/31 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Through modification of the strongest global fast terminal sliding mode control (GFTSMC) previously reported in the literature, a new sliding surface is proposed in this paper. Among all the FTSMC structures evaluated so far, the new surface exhibits the least chattering and the best error convergence trajectory with the addition of the logarithmic expression. The effectiveness of the low chattering GFTSMC (LCGFTSMC) is demonstrated on the non-isolated minimum-phase DC-DC power converter known as the Buck converter based on the direct SMC theory. In the direct SMC, hysteresis modulation (HM), which results in a fluctuating switching frequency, is replaced by parabolic modulation (PM), which offers a constant switching frequency. Dynamic results are obtained and compared for both modulations, taking into consideration one of the factors that cause the system’s switching frequency to fluctuate. Furthermore, and most importantly, the PM approach is compared to one of the techniques presented in the literature for fixed switching frequency, which is another significant part of this study. Because the closed loops offered for fixed switching frequencies have never been compared to each other prior to this work. A series of simulation and experimental tests have been carried out on the new sliding surface and the PM, and the results show that both provide remarkable dynamic responses compared to their counterparts.
一种新的改进的低抖振快速终端滑模非隔离最小相功率变换器控制方法。
本文通过对已有文献报道的最强全局快速终端滑模控制(GFTSMC)的改进,提出了一种新的滑模表面。在目前评估的所有FTSMC结构中,加入对数表达式后,新表面的抖振最小,误差收敛轨迹最好。在基于直接SMC理论的非隔离最小相位DC-DC功率变换器Buck变换器上验证了低颤振GFTSMC (LCGFTSMC)的有效性。在直接SMC中,导致开关频率波动的滞后调制(HM)被提供恒定开关频率的抛物调制(PM)所取代。考虑到引起系统开关频率波动的因素之一,对两种调制方式的动态结果进行了比较。此外,最重要的是,PM方法与固定开关频率的文献中提出的技术之一进行了比较,这是本研究的另一个重要部分。因为在此之前,从未对固定开关频率提供的闭环进行过相互比较。对新型滑动面和PM进行了一系列的仿真和实验测试,结果表明,与同类滑动面相比,两者都具有显著的动力响应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ISA transactions
ISA transactions 工程技术-工程:综合
CiteScore
11.70
自引率
12.30%
发文量
824
审稿时长
4.4 months
期刊介绍: ISA Transactions serves as a platform for showcasing advancements in measurement and automation, catering to both industrial practitioners and applied researchers. It covers a wide array of topics within measurement, including sensors, signal processing, data analysis, and fault detection, supported by techniques such as artificial intelligence and communication systems. Automation topics encompass control strategies, modelling, system reliability, and maintenance, alongside optimization and human-machine interaction. The journal targets research and development professionals in control systems, process instrumentation, and automation from academia and industry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书