Preparation and MR Imaging Study of a Recombinant Surface Antibody Superparamagnetic Iron Oxide Nanoparticle-EPC1 Molecular Probe for Hepatic Alveolar Echinococcosis.

IF 3.2
Weili Tian, Wenchao Ji, Wenya Liu, Peng Chen, Jun Li, Xueqi Sheng, Yaomiao Dong
{"title":"Preparation and MR Imaging Study of a Recombinant Surface Antibody Superparamagnetic Iron Oxide Nanoparticle-EPC1 Molecular Probe for Hepatic Alveolar Echinococcosis.","authors":"Weili Tian, Wenchao Ji, Wenya Liu, Peng Chen, Jun Li, Xueqi Sheng, Yaomiao Dong","doi":"10.2463/mrms.mp.2025-0096","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To establish a new hepatic alveolar echinococcosis (HAE) model, construct an EPC1 antibody-conjugated superparamagnetic iron oxide nanoparticle (SPION) molecular probe and evaluate the probe's efficacy in the targeted MRI of HAE.</p><p><strong>Methods: </strong>Thirty C57 female mice (9-10 weeks; 17-22g) were used to establish an HAE model via hepatic portal vein infection. Twenty successfully HAE-modeled mice were randomly divided into a control group, which was given a simple SPION tracer, and an experimental group, which was given a complex SPION-EPC1 tracer. In addition, a blocking group (n = 5), in which mice received an excess dose of free EPC1 antibody prior to injection of the SPION-EPC1 tracer, was included to assess EPC1-dependent targeting, and a gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) group (n = 5), which received 0.1 mmol/kg of Gd-DTPA, was included to provide a reference clinical contrast agent. MRI was performed using an animal MRI scanner, and T1- and T2-weighted imaging sequences were utilized to assess lesion characteristics before and after tracer injection at 1 and 4h time points. Subsequently, T2 signal intensity, the lesion SNR, and the lesion-to-liver contrast-to-noise ratio were measured by 2 blinded physicians (>5 years experience) using ImageJ software. Comparisons were made between plain and post-injection scans at 1 and 4h. Independent sample t-tests and non-parametric tests were applied to compare signal intensities and SNR values.</p><p><strong>Results: </strong>The SPION-EPC1 probe significantly decreased T2 signal intensity and lesion SNR in the experimental group at both 1 (T2 intensity: -24.3%; SNR: -35.2%) and 4h (T2 intensity: -23.5%; SNR: -43.1%) compared with plain scans. By contrast, the control group showed only transient decreases, with no significant differences at 4h. In the EPC1-blocking group, the T2-signal decrease at 4h was markedly attenuated compared with that of the SPION-EPC1 group and comparable to that of the SPION group, supporting EPC1-dependent targeting.</p><p><strong>Conclusion: </strong>The SPION-EPC1 molecular probe demonstrated improved sensitivity and long-lasting effects in the MRI detection of HAE lesions, offering a promising tool for early diagnosis and the potential advancement of clinical practice in HAE imaging.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2026-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13481155/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2025-0096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/10 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To establish a new hepatic alveolar echinococcosis (HAE) model, construct an EPC1 antibody-conjugated superparamagnetic iron oxide nanoparticle (SPION) molecular probe and evaluate the probe's efficacy in the targeted MRI of HAE.

Methods: Thirty C57 female mice (9-10 weeks; 17-22g) were used to establish an HAE model via hepatic portal vein infection. Twenty successfully HAE-modeled mice were randomly divided into a control group, which was given a simple SPION tracer, and an experimental group, which was given a complex SPION-EPC1 tracer. In addition, a blocking group (n = 5), in which mice received an excess dose of free EPC1 antibody prior to injection of the SPION-EPC1 tracer, was included to assess EPC1-dependent targeting, and a gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) group (n = 5), which received 0.1 mmol/kg of Gd-DTPA, was included to provide a reference clinical contrast agent. MRI was performed using an animal MRI scanner, and T1- and T2-weighted imaging sequences were utilized to assess lesion characteristics before and after tracer injection at 1 and 4h time points. Subsequently, T2 signal intensity, the lesion SNR, and the lesion-to-liver contrast-to-noise ratio were measured by 2 blinded physicians (>5 years experience) using ImageJ software. Comparisons were made between plain and post-injection scans at 1 and 4h. Independent sample t-tests and non-parametric tests were applied to compare signal intensities and SNR values.

Results: The SPION-EPC1 probe significantly decreased T2 signal intensity and lesion SNR in the experimental group at both 1 (T2 intensity: -24.3%; SNR: -35.2%) and 4h (T2 intensity: -23.5%; SNR: -43.1%) compared with plain scans. By contrast, the control group showed only transient decreases, with no significant differences at 4h. In the EPC1-blocking group, the T2-signal decrease at 4h was markedly attenuated compared with that of the SPION-EPC1 group and comparable to that of the SPION group, supporting EPC1-dependent targeting.

Conclusion: The SPION-EPC1 molecular probe demonstrated improved sensitivity and long-lasting effects in the MRI detection of HAE lesions, offering a promising tool for early diagnosis and the potential advancement of clinical practice in HAE imaging.

肝泡包虫病重组表面抗体超顺磁性氧化铁纳米颗粒- epc1分子探针的制备及磁共振成像研究。
目的:建立新型肝肺泡包虫病(HAE)模型,构建EPC1抗体偶联超顺磁性氧化铁纳米颗粒(SPION)分子探针,并评价该探针在HAE靶向MRI中的疗效。方法:C57雌性小鼠30只(9 ~ 10周,17 ~ 22g),经肝门静脉感染建立HAE模型。20只成功建立hae模型的小鼠随机分为对照组和实验组,对照组给予简单的SPION示踪剂,实验组给予复杂的SPION- epc1示踪剂。此外,我们还建立了阻断组(n = 5),其中小鼠在注射SPION-EPC1示踪剂之前接受了过量的游离EPC1抗体,以评估EPC1依赖性靶向性,并建立了钆-二乙烯三胺五乙酸(Gd-DTPA)组(n = 5),接受了0.1 mmol/kg的Gd-DTPA,以提供临床对照剂。采用动物MRI扫描仪进行MRI检查,并利用T1和t2加权成像序列评估示踪剂注射前后1和4h时间点病变特征。随后,由2名盲法医生(50 - 50年经验)使用ImageJ软件测量T2信号强度、病变信噪比和病变与肝脏的对比噪声比。在1和4小时进行平扫和注射后扫描的比较。采用独立样本t检验和非参数检验比较信号强度和信噪比值。结果:SPION-EPC1探针在1 h (T2强度:-24.3%;信噪比:-35.2%)和4h (T2强度:-23.5%;信噪比:-43.1%)均较平扫显著降低了实验组T2信号强度和病变信噪比。相比之下,对照组仅表现为短暂性下降,在4h时无显著差异。在epc1阻断组中,与SPION- epc1组相比,4h时t2信号下降明显减弱,与SPION组相当,支持epc1依赖性靶向。结论:SPION-EPC1分子探针在HAE病变的MRI检测中表现出更高的灵敏度和持久的效果,为HAE的早期诊断和临床成像提供了一个有希望的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书