{"title":"Breast phantom enhancement: Taguchi-type optimization for CT scan imaging quality and additive manufacturing realization.","authors":"Ying-Liang Chou, Fu-Tsai Chiang, Ching-Hsiu Ke, Jia-Hua Hsu, Chun-Chieh Liang, Samrit Kittipayak, Lung-Kwang Pan, Lung-Fa Pan, Kai-Yuan Cheng","doi":"10.1177/09287329261417465","DOIUrl":null,"url":null,"abstract":"<p><p>An indigenous breast phantom was customized to optimize the imaging quality of the CT scan according to Taguchi's methodology. A 3D printer made the base gauge of the breast phantom, and the polysmooth<sup>TM</sup> filament was sprayed. The gauge can be categorized into three major parts vertical and horizontal line pairs, two V-shape slices, and two arrays of nodules with various sizes, then a spherical shell mad by paraffin casting and the sunflower oil was infused as filling material. The Taguchi approach led to the development of a customized measuring device that enabled quantitative assessment aimed at improving the spatial resolution of CT image quality. Five essential factors for operating the CT chest scan (kVp, mAs, FOV, Pitch, and gantry rotation time) were organized according to Taguchi L<sub>18</sub>(2<sup>1</sup> × 3<sup>4</sup>) suggestion. Three well-trained radiologists ranked the imaging quality in three discrete time periods according to the imaging quality's sharpness, contrast, and spatial resolution. The derived average, standard deviation, and signal-to-noise ratio of specific factors were reorganized and analyzed from the multiple measurements to propose the optimal CT chest scan protocol recommendation. Accordingly, the optimal suggestion was A1(120 kVp), B3(200 mAs), C2(FOV 350 mm<sup>2</sup>), D1(pitch 0.516) and E2(rotation time 0.75 s) to fulfill the ALARA principle. In this research, a numerical metric termed the minimum detectable difference (MDD) was introduced to evaluate imaging performance, and its calculated value demonstrated a resolution capability of approximately 1.57 mm.</p>","PeriodicalId":48978,"journal":{"name":"Technology and Health Care","volume":" ","pages":"261-273"},"PeriodicalIF":1.3000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Health Care","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09287329261417465","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/12 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
An indigenous breast phantom was customized to optimize the imaging quality of the CT scan according to Taguchi's methodology. A 3D printer made the base gauge of the breast phantom, and the polysmoothTM filament was sprayed. The gauge can be categorized into three major parts vertical and horizontal line pairs, two V-shape slices, and two arrays of nodules with various sizes, then a spherical shell mad by paraffin casting and the sunflower oil was infused as filling material. The Taguchi approach led to the development of a customized measuring device that enabled quantitative assessment aimed at improving the spatial resolution of CT image quality. Five essential factors for operating the CT chest scan (kVp, mAs, FOV, Pitch, and gantry rotation time) were organized according to Taguchi L18(21 × 34) suggestion. Three well-trained radiologists ranked the imaging quality in three discrete time periods according to the imaging quality's sharpness, contrast, and spatial resolution. The derived average, standard deviation, and signal-to-noise ratio of specific factors were reorganized and analyzed from the multiple measurements to propose the optimal CT chest scan protocol recommendation. Accordingly, the optimal suggestion was A1(120 kVp), B3(200 mAs), C2(FOV 350 mm2), D1(pitch 0.516) and E2(rotation time 0.75 s) to fulfill the ALARA principle. In this research, a numerical metric termed the minimum detectable difference (MDD) was introduced to evaluate imaging performance, and its calculated value demonstrated a resolution capability of approximately 1.57 mm.
期刊介绍:
Technology and Health Care is intended to serve as a forum for the presentation of original articles and technical notes, observing rigorous scientific standards. Furthermore, upon invitation, reviews, tutorials, discussion papers and minisymposia are featured. The main focus of THC is related to the overlapping areas of engineering and medicine. The following types of contributions are considered:
1.Original articles: New concepts, procedures and devices associated with the use of technology in medical research and clinical practice are presented to a readership with a widespread background in engineering and/or medicine. In particular, the clinical benefit deriving from the application of engineering methods and devices in clinical medicine should be demonstrated. Typically, full length original contributions have a length of 4000 words, thereby taking duly into account figures and tables.
2.Technical Notes and Short Communications: Technical Notes relate to novel technical developments with relevance for clinical medicine. In Short Communications, clinical applications are shortly described. 3.Both Technical Notes and Short Communications typically have a length of 1500 words.
Reviews and Tutorials (upon invitation only): Tutorial and educational articles for persons with a primarily medical background on principles of engineering with particular significance for biomedical applications and vice versa are presented. The Editorial Board is responsible for the selection of topics.
4.Minisymposia (upon invitation only): Under the leadership of a Special Editor, controversial or important issues relating to health care are highlighted and discussed by various authors.
5.Letters to the Editors: Discussions or short statements (not indexed).