{"title":"Breast phantom enhancement: Taguchi-type optimization for CT scan imaging quality and additive manufacturing realization.","authors":"Ying-Liang Chou, Fu-Tsai Chiang, Ching-Hsiu Ke, Jia-Hua Hsu, Chun-Chieh Liang, Samrit Kittipayak, Lung-Kwang Pan, Lung-Fa Pan, Kai-Yuan Cheng","doi":"10.1177/09287329261417465","DOIUrl":null,"url":null,"abstract":"<p><p>An indigenous breast phantom was customized to optimize the imaging quality of the CT scan according to Taguchi's methodology. A 3D printer made the base gauge of the breast phantom, and the polysmooth<sup>TM</sup> filament was sprayed. The gauge can be categorized into three major parts vertical and horizontal line pairs, two V-shape slices, and two arrays of nodules with various sizes, then a spherical shell mad by paraffin casting and the sunflower oil was infused as filling material. The Taguchi approach led to the development of a customized measuring device that enabled quantitative assessment aimed at improving the spatial resolution of CT image quality. Five essential factors for operating the CT chest scan (kVp, mAs, FOV, Pitch, and gantry rotation time) were organized according to Taguchi L<sub>18</sub>(2<sup>1</sup> × 3<sup>4</sup>) suggestion. Three well-trained radiologists ranked the imaging quality in three discrete time periods according to the imaging quality's sharpness, contrast, and spatial resolution. The derived average, standard deviation, and signal-to-noise ratio of specific factors were reorganized and analyzed from the multiple measurements to propose the optimal CT chest scan protocol recommendation. Accordingly, the optimal suggestion was A1(120 kVp), B3(200 mAs), C2(FOV 350 mm<sup>2</sup>), D1(pitch 0.516) and E2(rotation time 0.75 s) to fulfill the ALARA principle. In this research, a numerical metric termed the minimum detectable difference (MDD) was introduced to evaluate imaging performance, and its calculated value demonstrated a resolution capability of approximately 1.57 mm.</p>","PeriodicalId":48978,"journal":{"name":"Technology and Health Care","volume":" ","pages":"261-273"},"PeriodicalIF":1.3000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Health Care","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09287329261417465","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/12 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

An indigenous breast phantom was customized to optimize the imaging quality of the CT scan according to Taguchi's methodology. A 3D printer made the base gauge of the breast phantom, and the polysmoothTM filament was sprayed. The gauge can be categorized into three major parts vertical and horizontal line pairs, two V-shape slices, and two arrays of nodules with various sizes, then a spherical shell mad by paraffin casting and the sunflower oil was infused as filling material. The Taguchi approach led to the development of a customized measuring device that enabled quantitative assessment aimed at improving the spatial resolution of CT image quality. Five essential factors for operating the CT chest scan (kVp, mAs, FOV, Pitch, and gantry rotation time) were organized according to Taguchi L18(21 × 34) suggestion. Three well-trained radiologists ranked the imaging quality in three discrete time periods according to the imaging quality's sharpness, contrast, and spatial resolution. The derived average, standard deviation, and signal-to-noise ratio of specific factors were reorganized and analyzed from the multiple measurements to propose the optimal CT chest scan protocol recommendation. Accordingly, the optimal suggestion was A1(120 kVp), B3(200 mAs), C2(FOV 350 mm2), D1(pitch 0.516) and E2(rotation time 0.75 s) to fulfill the ALARA principle. In this research, a numerical metric termed the minimum detectable difference (MDD) was introduced to evaluate imaging performance, and its calculated value demonstrated a resolution capability of approximately 1.57 mm.

乳房幻象增强:田口型优化CT扫描成像质量和增材制造实现。
根据田口的方法,定制一个本地乳房假体来优化CT扫描的成像质量。3D打印机制作了乳房假体的基本尺寸,并喷涂了聚光滑tm长丝。该压力表可分为三大部分:纵横线对、两组v形切片、两组大小不一的结节阵列,再浇铸一个石蜡制成的球形壳体,注入葵花籽油作为填充材料。田口的方法导致了定制测量设备的开发,该设备能够进行定量评估,旨在提高CT图像质量的空间分辨率。根据田口L18(21 × 34)建议,整理胸片CT扫描操作的5个基本因素(kVp、mAs、FOV、俯仰、龙门旋转时间)。三位训练有素的放射科医生根据成像质量的清晰度、对比度和空间分辨率,在三个离散的时间段内对成像质量进行排名。从多个测量结果中对特定因素的推导平均值、标准差和信噪比进行重组和分析,提出最佳CT胸部扫描方案推荐。因此,满足ALARA原理的最佳建议为A1(120 kVp)、B3(200 mAs)、C2(视场350 mm2)、D1(节距0.516)和E2(旋转时间0.75 s)。在这项研究中,引入了一个称为最小可检测差异(MDD)的数值度量来评估成像性能,其计算值表明分辨率能力约为1.57 mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Technology and Health Care
Technology and Health Care HEALTH CARE SCIENCES & SERVICES-ENGINEERING, BIOMEDICAL
CiteScore
2.10
自引率
6.20%
发文量
282
审稿时长
>12 weeks
期刊介绍: Technology and Health Care is intended to serve as a forum for the presentation of original articles and technical notes, observing rigorous scientific standards. Furthermore, upon invitation, reviews, tutorials, discussion papers and minisymposia are featured. The main focus of THC is related to the overlapping areas of engineering and medicine. The following types of contributions are considered: 1.Original articles: New concepts, procedures and devices associated with the use of technology in medical research and clinical practice are presented to a readership with a widespread background in engineering and/or medicine. In particular, the clinical benefit deriving from the application of engineering methods and devices in clinical medicine should be demonstrated. Typically, full length original contributions have a length of 4000 words, thereby taking duly into account figures and tables. 2.Technical Notes and Short Communications: Technical Notes relate to novel technical developments with relevance for clinical medicine. In Short Communications, clinical applications are shortly described. 3.Both Technical Notes and Short Communications typically have a length of 1500 words. Reviews and Tutorials (upon invitation only): Tutorial and educational articles for persons with a primarily medical background on principles of engineering with particular significance for biomedical applications and vice versa are presented. The Editorial Board is responsible for the selection of topics. 4.Minisymposia (upon invitation only): Under the leadership of a Special Editor, controversial or important issues relating to health care are highlighted and discussed by various authors. 5.Letters to the Editors: Discussions or short statements (not indexed).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书