Dosimetry of 131Cs Liquid-filled intracavitary balloon brachytherapy for enhanced treatment planning: utilizing TL dosimetry (TLD) and Monte Carlo calculation.

IF 2.4 4区 环境科学与生态学 Q3 BIOLOGY
Radiation and Environmental Biophysics Pub Date : 2026-03-01 Epub Date: 2026-02-12 DOI:10.1007/s00411-026-01196-w
Amir Kazemi, Dariush Sardari, Hosein Poorbaygi, Asghar Hadadi, Shahab Sheibani
{"title":"Dosimetry of <sup>131</sup>Cs Liquid-filled intracavitary balloon brachytherapy for enhanced treatment planning: utilizing TL dosimetry (TLD) and Monte Carlo calculation.","authors":"Amir Kazemi, Dariush Sardari, Hosein Poorbaygi, Asghar Hadadi, Shahab Sheibani","doi":"10.1007/s00411-026-01196-w","DOIUrl":null,"url":null,"abstract":"<p><p>An intracavity balloon filled with <sup>131</sup>Cs liquid was investigated to be used in brachytherapy, particularly for the treatment of glioblastoma multiforme (GBM), with a reference of 40-60 Gy at a depth of 1 cm. The dosimetric characteristics of the liquid <sup>131</sup>Cs, as a low-energy photon source for brachytherapy, were assessed. For this, thermoluminescence dosimetry was used for experimental validation, while Monte Carlo calculations were performed to evaluate dose rate distributions for treatment planning. To prepare the <sup>131</sup>Cs solution, natural BaCO<sub>3</sub> was used as a target irradiated in a thermal neutron flux of 3.5 × 10<sup>13</sup> n/cm<sup>2</sup>/s at the Tehran Research Reactor (TRR), and the separation of <sup>131</sup>Cs with a radionuclide purity of 99% was confirmed using a radiochemical method. A well counter was employed to measure the activity of the <sup>131</sup>Cs solution. The dosimetric measurements were conducted using a newly designed phantom in the form of a hollow sphere, as well as a water tank and thermoluminescence dosimeters (TLDs). The results were utilized to validate the accuracy of the dose distribution simulated with the MCNP5 Monte Carlo radiation transport code and a volumetric dose algorithm for predicting dose to water. The ± 8% agreement obtained between TLD measurements and MCNP5 simulations (with an uncertainty of ± 12.3%) confirms the validity of the model. The calculated dose rates in water and brain tissue were 0.0127 Gy/h and 0.0131 Gy/h at a reference depth of 0.5 cm per 37MBq, respectively. To calculate the activity relative to the balloon volume, two equations were deduced for volumes below and above 15 cm<sup>3</sup>. The results indicate that the validated dose rate can be used to develop a treatment planning method including a liquid <sup>131</sup>Cs source for brachytherapy applications.</p>","PeriodicalId":21002,"journal":{"name":"Radiation and Environmental Biophysics","volume":" ","pages":"539-548"},"PeriodicalIF":2.4000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation and Environmental Biophysics","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1007/s00411-026-01196-w","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

An intracavity balloon filled with 131Cs liquid was investigated to be used in brachytherapy, particularly for the treatment of glioblastoma multiforme (GBM), with a reference of 40-60 Gy at a depth of 1 cm. The dosimetric characteristics of the liquid 131Cs, as a low-energy photon source for brachytherapy, were assessed. For this, thermoluminescence dosimetry was used for experimental validation, while Monte Carlo calculations were performed to evaluate dose rate distributions for treatment planning. To prepare the 131Cs solution, natural BaCO3 was used as a target irradiated in a thermal neutron flux of 3.5 × 1013 n/cm2/s at the Tehran Research Reactor (TRR), and the separation of 131Cs with a radionuclide purity of 99% was confirmed using a radiochemical method. A well counter was employed to measure the activity of the 131Cs solution. The dosimetric measurements were conducted using a newly designed phantom in the form of a hollow sphere, as well as a water tank and thermoluminescence dosimeters (TLDs). The results were utilized to validate the accuracy of the dose distribution simulated with the MCNP5 Monte Carlo radiation transport code and a volumetric dose algorithm for predicting dose to water. The ± 8% agreement obtained between TLD measurements and MCNP5 simulations (with an uncertainty of ± 12.3%) confirms the validity of the model. The calculated dose rates in water and brain tissue were 0.0127 Gy/h and 0.0131 Gy/h at a reference depth of 0.5 cm per 37MBq, respectively. To calculate the activity relative to the balloon volume, two equations were deduced for volumes below and above 15 cm3. The results indicate that the validated dose rate can be used to develop a treatment planning method including a liquid 131Cs source for brachytherapy applications.

131Cs腔内充液球囊近距离放射治疗强化治疗方案的剂量测定:利用TL剂量法(TLD)和蒙特卡罗计算。
研究了一种填充131Cs液体的腔内球囊用于近距离治疗,特别是用于治疗多形性胶质母细胞瘤(GBM),参考剂量为40-60 Gy,深度为1cm。评估了液态131c作为近距离治疗的低能量光子源的剂量学特性。为此,使用热释光剂量法进行实验验证,同时使用蒙特卡罗计算来评估治疗计划的剂量率分布。以天然BaCO3为靶,在德黑兰研究堆(TRR)以3.5 × 1013 n/cm2/s的热中子通量辐照制备131Cs溶液,用放射化学方法证实了131Cs的分离,其放射性核素纯度为99%。用井计数器测量131c溶液的活度。剂量测量使用新设计的空心球体、水箱和热释光剂量计(tld)进行。研究结果验证了MCNP5蒙特卡罗辐射输运代码和体积剂量算法模拟的剂量分布的准确性。TLD测量结果与MCNP5模拟结果(不确定性为±12.3%)的一致性为±8%,证实了该模型的有效性。在参考深度为0.5 cm / 37MBq时,水和脑组织的计算剂量率分别为0.0127 Gy/h和0.0131 Gy/h。为了计算相对于气球体积的活度,推导了体积低于和高于15 cm3的两个方程。结果表明,验证的剂量率可用于开发包括液体131c源的近距离治疗计划方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.00
自引率
5.90%
发文量
53
审稿时长
>36 weeks
期刊介绍: This journal is devoted to fundamental and applied issues in radiation research and biophysics. The topics may include: Biophysics of ionizing radiation: radiation physics and chemistry, radiation dosimetry, radiobiology, radioecology, biophysical foundations of medical applications of radiation, and radiation protection. Biological effects of radiation: experimental or theoretical work on molecular or cellular effects; relevance of biological effects for risk assessment; biological effects of medical applications of radiation; relevance of radiation for biosphere and in space; modelling of ecosystems; modelling of transport processes of substances in biotic systems. Risk assessment: epidemiological studies of cancer and non-cancer effects; quantification of risk including exposures to radiation and confounding factors Contributions to these topics may include theoretical-mathematical and experimental material, as well as description of new techniques relevant for the study of these issues. They can range from complex radiobiological phenomena to issues in health physics and environmental protection.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书