{"title":"Performance Comparison between Semi-Automated and Manual Cell Counting for Animal Cell Culture","authors":"Selina Uhlendorff, Prof. Dr. Ulrich Odefey, Prof. Dr. Björn Frahm, Prof. Dr. Miriam Pein-Hackelbusch","doi":"10.1002/cite.70048","DOIUrl":null,"url":null,"abstract":"<p>Determining cell density and viability with (semi-)automated methods enables rapid cell cultivation analysis. However, scientific validation is required, typically by comparing results to manual counting. To address this, we present a method to evaluate and compare two cell counting methods exemplified by a manual and a semi-automated method (Countstar BioTech). Experiments followed validation parameters aligned with the International Council for Harmonization (ICH) Q2(R1) guideline and a dilution series design based on ISO 20391-2:2019. Both the semi-automated and manual methods showed comparable specificity and linearity for Chinese hamster ovary (CHO)-K1 cells. The semi-automated method exhibited superior repeatability for total cell density, whereas cell viability results showed no significant difference.</p>","PeriodicalId":9912,"journal":{"name":"Chemie Ingenieur Technik","volume":"98 1-2","pages":"57-63"},"PeriodicalIF":1.6000,"publicationDate":"2025-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cite.70048","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemie Ingenieur Technik","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cite.70048","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Determining cell density and viability with (semi-)automated methods enables rapid cell cultivation analysis. However, scientific validation is required, typically by comparing results to manual counting. To address this, we present a method to evaluate and compare two cell counting methods exemplified by a manual and a semi-automated method (Countstar BioTech). Experiments followed validation parameters aligned with the International Council for Harmonization (ICH) Q2(R1) guideline and a dilution series design based on ISO 20391-2:2019. Both the semi-automated and manual methods showed comparable specificity and linearity for Chinese hamster ovary (CHO)-K1 cells. The semi-automated method exhibited superior repeatability for total cell density, whereas cell viability results showed no significant difference.
期刊介绍:
Die Chemie Ingenieur Technik ist die wohl angesehenste deutschsprachige Zeitschrift für Verfahrensingenieure, technische Chemiker, Apparatebauer und Biotechnologen. Als Fachorgan von DECHEMA, GDCh und VDI-GVC gilt sie als das unverzichtbare Forum für den Erfahrungsaustausch zwischen Forschern und Anwendern aus Industrie, Forschung und Entwicklung. Wissenschaftlicher Fortschritt und Praxisnähe: Eine Kombination, die es nur in der CIT gibt!