Improved Air-Coupled Ultrasonic Transmission Using Pulse Compression

IF 1.8
Mate Gaal;Pascal Wernicke
{"title":"Improved Air-Coupled Ultrasonic Transmission Using Pulse Compression","authors":"Mate Gaal;Pascal Wernicke","doi":"10.1109/OJUFFC.2026.3659047","DOIUrl":null,"url":null,"abstract":"Air-coupled ultrasonic testing avoids contamination and reduces maintenance costs, but suffers from poor signal-to-noise ratio (SNR) due to impedance mismatch. Rather than developing new transducers, this study improves SNR through signal processing by adapting pulse compression from radar. We propose a method using unipolar square pulses to make pulse compression compatible with non-linear transducers such as ferroelectrets and thermoacoustic emitters. Instead of relying on analytical models, a reference transmission measurement served as the matched filter, simplifying implementation and ensuring adaptability across transducer types. We evaluated unipolar coded excitation and pulse compression on ultrasonic transmission through a 25 mm polyvinyl chloride plate, varying code length and pulse delay. Significant SNR gains were observed across transducers, particularly with longer delays. These results confirm that pulse compression enhances peak localization and supports testing under low-SNR conditions. Further experiments showed that pulse compression remains effective despite side lobe overlap and noise, provided the pulse delay is chosen appropriately. Although SNR prediction is limited by electrical and acoustic interference, the method consistently improves detection. Overall, the results demonstrate the feasibility of unipolar excitation coding for pulse compression in air-coupled ultrasonic testing, with practical value for thick or attenuating materials.","PeriodicalId":73301,"journal":{"name":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","volume":"6 ","pages":"9-16"},"PeriodicalIF":1.8000,"publicationDate":"2026-01-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11366931","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE open journal of ultrasonics, ferroelectrics, and frequency control","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11366931/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Air-coupled ultrasonic testing avoids contamination and reduces maintenance costs, but suffers from poor signal-to-noise ratio (SNR) due to impedance mismatch. Rather than developing new transducers, this study improves SNR through signal processing by adapting pulse compression from radar. We propose a method using unipolar square pulses to make pulse compression compatible with non-linear transducers such as ferroelectrets and thermoacoustic emitters. Instead of relying on analytical models, a reference transmission measurement served as the matched filter, simplifying implementation and ensuring adaptability across transducer types. We evaluated unipolar coded excitation and pulse compression on ultrasonic transmission through a 25 mm polyvinyl chloride plate, varying code length and pulse delay. Significant SNR gains were observed across transducers, particularly with longer delays. These results confirm that pulse compression enhances peak localization and supports testing under low-SNR conditions. Further experiments showed that pulse compression remains effective despite side lobe overlap and noise, provided the pulse delay is chosen appropriately. Although SNR prediction is limited by electrical and acoustic interference, the method consistently improves detection. Overall, the results demonstrate the feasibility of unipolar excitation coding for pulse compression in air-coupled ultrasonic testing, with practical value for thick or attenuating materials.
利用脉冲压缩改进空气耦合超声传输
空气耦合超声检测避免了污染,降低了维护成本,但由于阻抗不匹配,信噪比(SNR)较差。本研究不是开发新的换能器,而是通过适应雷达脉冲压缩的信号处理来提高信噪比。我们提出了一种使用单极方脉冲的方法,使脉冲压缩与非线性换能器(如铁驻极体和热声发射器)兼容。代替依赖于分析模型,参考传输测量作为匹配滤波器,简化了实现并确保了跨换能器类型的适应性。我们评估了单极编码激励和脉冲压缩超声传输通过25毫米聚氯乙烯板,不同的编码长度和脉冲延迟。在换能器上观察到显著的信噪比增益,特别是在较长的延迟下。这些结果证实了脉冲压缩增强了峰值定位,并支持在低信噪比条件下的测试。进一步的实验表明,在适当选择脉冲延迟的情况下,尽管存在旁瓣重叠和噪声,脉冲压缩仍然有效。尽管信噪比预测受到电和声干扰的限制,但该方法不断提高检测效率。结果表明,单极激励编码用于空气耦合超声检测脉冲压缩的可行性,对厚材料或衰减材料具有实用价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书