{"title":"Hybrid solar–exhaust heat recovery heat pump system: A combined experimental and numerical study for high-efficiency sustainable heating","authors":"Rabih Murr ,&nbsp;Tarek Ibrahim ,&nbsp;Nicolas Youssef ,&nbsp;Samer Ali ,&nbsp;Wassim Salameh ,&nbsp;Jalal Faraj ,&nbsp;Mahmoud Khaled","doi":"10.1016/j.uncres.2026.100348","DOIUrl":null,"url":null,"abstract":"<div><div>A significant portion of building energy consumption is attributed to space heating, while a significant amount of power generator waste heat is left unused. At the same time, solar energy's sporadic nature restricts its use as a stand-alone heating source. The objective of this research is to design and evaluate a hybrid heat pump system that combines solar air heating with power generator exhaust gas recovery in order to minimize greenhouse gas emissions, improve energy efficiency, and consume less fuel in cold-climate operations. In contrast to traditional exhaust-recovery or solar-assisted systems, the suggested setup integrates waste-heat and dual renewable sources in various configurations to find the best thermodynamic performance. Through experimental validation and computational modelling, the unique hybrid design for sustainable heating is established by integrating solar and exhaust heat recovery with a heat pump cycle. Six system configurations were examined covering all possible integration sequences of the heat pump, exhaust gas recovery, and solar air heating components. Field data from a 45 kVA generator and 12 m-long solar air tubes were integrated with thermodynamic modelling in a combined simulation experimental framework. At −5 °C ambient conditions, the configuration combining the heat pump, solar air heater, and exhaust gas recovery produced the highest coefficient of performance, with a boost of up to 4770%. The system achieved significant monthly energy and cost savings, as well as up to 98% reductions in carbon dioxide emissions. While the integration of these distinct dynamic heat sources present control challenges, the modular nature of the system affirms feasible application across different scales of buildings. For next-generation building heating systems, this hybrid heat recovery technology provides an extremely effective and environmentally friendly option. This study illustrates the capabilities of hybrid renewable–waste heat recovery systems for the sustainable heating of buildings, paving the road for future experimental work and thermal energy storage integration.</div></div>","PeriodicalId":101263,"journal":{"name":"Unconventional Resources","volume":"11 ","pages":"Article 100348"},"PeriodicalIF":4.6000,"publicationDate":"2026-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Unconventional Resources","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666519026000452","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/12 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A significant portion of building energy consumption is attributed to space heating, while a significant amount of power generator waste heat is left unused. At the same time, solar energy's sporadic nature restricts its use as a stand-alone heating source. The objective of this research is to design and evaluate a hybrid heat pump system that combines solar air heating with power generator exhaust gas recovery in order to minimize greenhouse gas emissions, improve energy efficiency, and consume less fuel in cold-climate operations. In contrast to traditional exhaust-recovery or solar-assisted systems, the suggested setup integrates waste-heat and dual renewable sources in various configurations to find the best thermodynamic performance. Through experimental validation and computational modelling, the unique hybrid design for sustainable heating is established by integrating solar and exhaust heat recovery with a heat pump cycle. Six system configurations were examined covering all possible integration sequences of the heat pump, exhaust gas recovery, and solar air heating components. Field data from a 45 kVA generator and 12 m-long solar air tubes were integrated with thermodynamic modelling in a combined simulation experimental framework. At −5 °C ambient conditions, the configuration combining the heat pump, solar air heater, and exhaust gas recovery produced the highest coefficient of performance, with a boost of up to 4770%. The system achieved significant monthly energy and cost savings, as well as up to 98% reductions in carbon dioxide emissions. While the integration of these distinct dynamic heat sources present control challenges, the modular nature of the system affirms feasible application across different scales of buildings. For next-generation building heating systems, this hybrid heat recovery technology provides an extremely effective and environmentally friendly option. This study illustrates the capabilities of hybrid renewable–waste heat recovery systems for the sustainable heating of buildings, paving the road for future experimental work and thermal energy storage integration.

Abstract Image

混合太阳能-废气热回收热泵系统:高效可持续供暖的实验与数值结合研究
建筑能源消耗的很大一部分是空间供暖,而大量的发电机余热未被利用。同时,太阳能的散发性限制了它作为独立热源的使用。本研究的目的是设计和评估一种混合热泵系统,该系统将太阳能空气加热与发电机废气回收相结合,以最大限度地减少温室气体排放,提高能源效率,并在寒冷气候下减少燃料消耗。与传统的废气回收或太阳能辅助系统相比,建议的设置将废热和双重可再生能源整合在不同的配置中,以找到最佳的热力学性能。通过实验验证和计算建模,通过将太阳能和废热回收与热泵循环相结合,建立了独特的可持续供暖混合设计。研究了六种系统配置,涵盖了热泵、废气回收和太阳能空气加热组件的所有可能的集成顺序。在联合模拟实验框架中,将来自45千伏安发电机和12米长的太阳能空气管的现场数据与热力学建模相结合。在- 5°C的环境条件下,热泵、太阳能空气加热器和废气回收的组合配置产生了最高的性能系数,提升幅度高达4770%。该系统实现了每月显著的能源和成本节约,并减少了高达98%的二氧化碳排放量。虽然这些不同的动态热源的集成带来了控制方面的挑战,但系统的模块化特性肯定了在不同规模的建筑物上的可行应用。对于下一代建筑供暖系统,这种混合热回收技术提供了一个非常有效和环保的选择。本研究说明了混合可再生-废热回收系统在建筑可持续供暖方面的能力,为未来的实验工作和热能储存集成铺平了道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书