Seohee Han, Hyunwoo Lim, Jonghyeok Lee, Hyosung Cho
{"title":"Quantitative analysis of grid geometry effects on spatial harmonic imaging–based single-grid phase-contrast X-ray imaging","authors":"Seohee Han, Hyunwoo Lim, Jonghyeok Lee, Hyosung Cho","doi":"10.1016/j.net.2026.104179","DOIUrl":null,"url":null,"abstract":"<div><div>Single-grid phase-contrast X-ray imaging (SG-PCXI) enables simultaneous reconstruction of absorption, phase-contrast, and dark-field images from a single exposure using spatial harmonic imaging (SHI). Although the geometry of X-ray absorbing grids is known to influence imaging performance, its quantitative impact on SHI-based SG-PCXI has not been systematically characterized. This study investigates how the duty cycle (DC) and strip height of a grid affect fringe modulation, harmonic separation, and the resulting phase and dark-field sensitivity. Monte Carlo simulations were performed using the GATE 9.0 platform under controlled conditions (1 μm focal spot size and 10 μm detector pixel size). Increasing the DC from 0.16 to 0.66 improved grid visibility (GV) from 0.25 to 0.91 and the harmonic peak ratio (HPR) from 0.11 to 0.73. Increasing the strip height from 1.5 to 24.1 μm similarly raised GV from 0.09 to 0.91 and the HPR from 0.04 to 0.73. These changes resulted in a substantial increase in the edge signal-to-noise ratio (ESNR), from 5.4 to 32.6, with clearer edge definition in differential phase-contrast images and increased contrast in dark-field images. This work elucidates fundamental relationships between grid geometry, fringe modulation, and SHI performance, providing a quantitative basis for understanding design trade-offs in laboratory-scale SG-PCXI.</div></div>","PeriodicalId":19272,"journal":{"name":"Nuclear Engineering and Technology","volume":"58 6","pages":"Article 104179"},"PeriodicalIF":2.9000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Engineering and Technology","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1738573326000677","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/2 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Single-grid phase-contrast X-ray imaging (SG-PCXI) enables simultaneous reconstruction of absorption, phase-contrast, and dark-field images from a single exposure using spatial harmonic imaging (SHI). Although the geometry of X-ray absorbing grids is known to influence imaging performance, its quantitative impact on SHI-based SG-PCXI has not been systematically characterized. This study investigates how the duty cycle (DC) and strip height of a grid affect fringe modulation, harmonic separation, and the resulting phase and dark-field sensitivity. Monte Carlo simulations were performed using the GATE 9.0 platform under controlled conditions (1 μm focal spot size and 10 μm detector pixel size). Increasing the DC from 0.16 to 0.66 improved grid visibility (GV) from 0.25 to 0.91 and the harmonic peak ratio (HPR) from 0.11 to 0.73. Increasing the strip height from 1.5 to 24.1 μm similarly raised GV from 0.09 to 0.91 and the HPR from 0.04 to 0.73. These changes resulted in a substantial increase in the edge signal-to-noise ratio (ESNR), from 5.4 to 32.6, with clearer edge definition in differential phase-contrast images and increased contrast in dark-field images. This work elucidates fundamental relationships between grid geometry, fringe modulation, and SHI performance, providing a quantitative basis for understanding design trade-offs in laboratory-scale SG-PCXI.
期刊介绍:
Nuclear Engineering and Technology (NET), an international journal of the Korean Nuclear Society (KNS), publishes peer-reviewed papers on original research, ideas and developments in all areas of the field of nuclear science and technology. NET bimonthly publishes original articles, reviews, and technical notes. The journal is listed in the Science Citation Index Expanded (SCIE) of Thomson Reuters.
NET covers all fields for peaceful utilization of nuclear energy and radiation as follows:
1) Reactor Physics
2) Thermal Hydraulics
3) Nuclear Safety
4) Nuclear I&C
5) Nuclear Physics, Fusion, and Laser Technology
6) Nuclear Fuel Cycle and Radioactive Waste Management
7) Nuclear Fuel and Reactor Materials
8) Radiation Application
9) Radiation Protection
10) Nuclear Structural Analysis and Plant Management & Maintenance
11) Nuclear Policy, Economics, and Human Resource Development