Preparation of ZIF-8 grafted magnetic solid-phase extraction sorbent for sensitive determination of four cannabinoids in urine and oral fluid

IF 6.1 2区 化学 Q1 CHEMISTRY, ANALYTICAL
Analytica Chimica Acta Pub Date : 2026-04-08 Epub Date: 2026-02-10 DOI:10.1016/j.aca.2026.345194
Hongyu Ning , Yilei Fan , Haodong Wang , Huijun Liu , Zhongping Huang , Haixing Wang , Xing Ke , Yu Xu
{"title":"Preparation of ZIF-8 grafted magnetic solid-phase extraction sorbent for sensitive determination of four cannabinoids in urine and oral fluid","authors":"Hongyu Ning ,&nbsp;Yilei Fan ,&nbsp;Haodong Wang ,&nbsp;Huijun Liu ,&nbsp;Zhongping Huang ,&nbsp;Haixing Wang ,&nbsp;Xing Ke ,&nbsp;Yu Xu","doi":"10.1016/j.aca.2026.345194","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>The global increase in cannabis use has created a strong demand for reliable and efficient detection methods. Traditional urine-based assays are widely used and standardized, but suffer from complex hydrolysis requirements, long detection windows, and an inability to monitor recent use. In contrast, oral fluid testing enables non-invasive, real-time detection of parent cannabinoids, but is limited by low sample volume, matrix interference, and insufficient sensitivity in common rapid tests. It is clear that a sample preparation and detection approach is needed that is robust, highly sensitive, streamlined, and compatible with high-throughput confirmatory analysis such as LC-MS/MS.</div></div><div><h3>Results</h3><div>In this study, a magnetic solid-phase extraction (MSPE) method was developed using a novel magnetic metal–organic framework composite, Fe<sub>3</sub>O<sub>4</sub>@poly(GMA/DVB-ZIF-8), for the efficient extraction of four cannabinoids from urine and oral fluid. The sorbent uses multiple interactions—including hydrophobic, π–π, electrostatic, and Zn–O coordination—to achieve high analyte recovery (exceeding 85%). Coupled with UHPLC-MS/MS analysis, the method demonstrates wide linearity (0.05–25 ng/mL, r<sup>2</sup> &gt; 0.9945), low detection limits (as low as 0.017 ng/mL), and good repeatability (RSDs &lt;13.8%). Comparative evaluation with conventional liquid–liquid extraction showed minimal deviation (relative percent difference &lt;6.0%), confirming high trueness and reliability for cannabinoid monitoring in biological samples.</div></div><div><h3>Significance</h3><div>This MSPE approach provides a simple, efficient and high-throughput sample preparation method for reliable and rapid forensic analysis of cannabinoids in complex biological samples.</div></div>","PeriodicalId":240,"journal":{"name":"Analytica Chimica Acta","volume":"1394 ","pages":"Article 345194"},"PeriodicalIF":6.1000,"publicationDate":"2026-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica Chimica Acta","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0003267026001443","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/10 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Background

The global increase in cannabis use has created a strong demand for reliable and efficient detection methods. Traditional urine-based assays are widely used and standardized, but suffer from complex hydrolysis requirements, long detection windows, and an inability to monitor recent use. In contrast, oral fluid testing enables non-invasive, real-time detection of parent cannabinoids, but is limited by low sample volume, matrix interference, and insufficient sensitivity in common rapid tests. It is clear that a sample preparation and detection approach is needed that is robust, highly sensitive, streamlined, and compatible with high-throughput confirmatory analysis such as LC-MS/MS.

Results

In this study, a magnetic solid-phase extraction (MSPE) method was developed using a novel magnetic metal–organic framework composite, Fe3O4@poly(GMA/DVB-ZIF-8), for the efficient extraction of four cannabinoids from urine and oral fluid. The sorbent uses multiple interactions—including hydrophobic, π–π, electrostatic, and Zn–O coordination—to achieve high analyte recovery (exceeding 85%). Coupled with UHPLC-MS/MS analysis, the method demonstrates wide linearity (0.05–25 ng/mL, r2 > 0.9945), low detection limits (as low as 0.017 ng/mL), and good repeatability (RSDs <13.8%). Comparative evaluation with conventional liquid–liquid extraction showed minimal deviation (relative percent difference <6.0%), confirming high trueness and reliability for cannabinoid monitoring in biological samples.

Significance

This MSPE approach provides a simple, efficient and high-throughput sample preparation method for reliable and rapid forensic analysis of cannabinoids in complex biological samples.

Abstract Image

ZIF-8接枝磁性固相萃取吸附剂的制备及其对尿液和口服液中四种大麻素的灵敏测定
全球大麻使用的增加对可靠和有效的检测方法产生了强烈的需求。传统的基于尿液的检测方法被广泛使用和标准化,但存在复杂的水解要求,较长的检测窗口,以及无法监测最近的使用。相比之下,口腔液检测能够非侵入性、实时检测母体大麻素,但受普通快速检测中样本量小、基质干扰和灵敏度不足的限制。很明显,需要一种稳健、高灵敏度、流线型的样品制备和检测方法,并与LC-MS/MS等高通量验证性分析兼容。结果采用新型磁性金属-有机骨架复合材料Fe3O4@poly(GMA/DVB-ZIF-8),建立了从尿液和口服液中高效提取四种大麻素的磁固相萃取(MSPE)方法。该吸附剂使用多种相互作用,包括疏水、π -π、静电和Zn-O配位,以实现高分析物回收率(超过85%)。结合UHPLC-MS/MS分析,该方法线性宽(0.05 ~ 25 ng/mL, r2 > 0.9945),检出限低(低至0.017 ng/mL),重复性好(rsd <13.8%)。与常规液液萃取法的对比评价偏差最小(相对百分比差<;6.0%),证实了生物样品中大麻素监测的高准确性和可靠性。意义该方法为复杂生物样品中大麻素的可靠、快速法医分析提供了一种简单、高效、高通量的样品制备方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytica Chimica Acta
Analytica Chimica Acta 化学-分析化学
CiteScore
10.40
自引率
6.50%
发文量
1081
审稿时长
38 days
期刊介绍: Analytica Chimica Acta has an open access mirror journal Analytica Chimica Acta: X, sharing the same aims and scope, editorial team, submission system and rigorous peer review. Analytica Chimica Acta provides a forum for the rapid publication of original research, and critical, comprehensive reviews dealing with all aspects of fundamental and applied modern analytical chemistry. The journal welcomes the submission of research papers which report studies concerning the development of new and significant analytical methodologies. In determining the suitability of submitted articles for publication, particular scrutiny will be placed on the degree of novelty and impact of the research and the extent to which it adds to the existing body of knowledge in analytical chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书