A dual-mode electrochemiluminescence/SERS biosensor for B-type natriuretic peptide based on a T7–CRISPR/Cas13a cascade and a CsPbBr3@PDA@Au perovskite interface
Yang Li , Haozhen Ren , Runze Wu , Jiahui Wang , Yuanxun Gong , Qianli Tang , Xianjiu Liao , Kai Zhang , Longjian Huang , Jihua Wei
{"title":"A dual-mode electrochemiluminescence/SERS biosensor for B-type natriuretic peptide based on a T7–CRISPR/Cas13a cascade and a CsPbBr3@PDA@Au perovskite interface","authors":"Yang Li , Haozhen Ren , Runze Wu , Jiahui Wang , Yuanxun Gong , Qianli Tang , Xianjiu Liao , Kai Zhang , Longjian Huang , Jihua Wei","doi":"10.1016/j.bios.2026.118484","DOIUrl":null,"url":null,"abstract":"<div><div>B-type natriuretic peptide (BNP) is an important biomarker for cardiovascular diseases, motivating sensitive and robust quantification in complex matrices. Here we report a single-electrode, anti-correlated dual-mode electrochemiluminescence/surface-enhanced Raman scattering (ECL/SERS) biosensor that couples split-aptamer recognition with a solution-phase T7 transcription–CRISPR/Cas13a cascade and an interfacial toehold-mediated strand-displacement “probe-stripping” transduction on a CsPbBr<sub>3</sub>@PDA@Au-modified glassy carbon electrode. BNP binding releases an active T7 template to generate trigger RNA, which activates Cas13a collateral cleavage to produce initiator strands for interfacial unlocking. The interface reaction removes ferrocene/Raman co-labeled probes, synchronizing ECL turn-on with SERS turn-off and enabling ratiometric quantification (R = I<sub>ECL</sub>/I<sub>SERS</sub>) to suppress common-mode variability. The sensor provides BNP determination over 0–10<sup>6</sup> aM with log-linear single-mode calibrations and a continuous ratiometric response. Selectivity was validated against multiple interferents and the structurally related peptide NT-proBNP at the same concentration (10<sup>6</sup> aM), showing negligible ratiometric change relative to BNP. Serum-sample evaluation and stability tests further support feasibility in complex matrices. This work establishes a cascade-to-interface ratiometric strategy for robust protein biosensing.</div></div>","PeriodicalId":259,"journal":{"name":"Biosensors and Bioelectronics","volume":"301 ","pages":"Article 118484"},"PeriodicalIF":11.8000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosensors and Bioelectronics","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0956566326001168","RegionNum":1,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOPHYSICS","Score":null,"Total":0}
引用次数: 0
Abstract
B-type natriuretic peptide (BNP) is an important biomarker for cardiovascular diseases, motivating sensitive and robust quantification in complex matrices. Here we report a single-electrode, anti-correlated dual-mode electrochemiluminescence/surface-enhanced Raman scattering (ECL/SERS) biosensor that couples split-aptamer recognition with a solution-phase T7 transcription–CRISPR/Cas13a cascade and an interfacial toehold-mediated strand-displacement “probe-stripping” transduction on a CsPbBr3@PDA@Au-modified glassy carbon electrode. BNP binding releases an active T7 template to generate trigger RNA, which activates Cas13a collateral cleavage to produce initiator strands for interfacial unlocking. The interface reaction removes ferrocene/Raman co-labeled probes, synchronizing ECL turn-on with SERS turn-off and enabling ratiometric quantification (R = IECL/ISERS) to suppress common-mode variability. The sensor provides BNP determination over 0–106 aM with log-linear single-mode calibrations and a continuous ratiometric response. Selectivity was validated against multiple interferents and the structurally related peptide NT-proBNP at the same concentration (106 aM), showing negligible ratiometric change relative to BNP. Serum-sample evaluation and stability tests further support feasibility in complex matrices. This work establishes a cascade-to-interface ratiometric strategy for robust protein biosensing.
期刊介绍:
Biosensors & Bioelectronics, along with its open access companion journal Biosensors & Bioelectronics: X, is the leading international publication in the field of biosensors and bioelectronics. It covers research, design, development, and application of biosensors, which are analytical devices incorporating biological materials with physicochemical transducers. These devices, including sensors, DNA chips, electronic noses, and lab-on-a-chip, produce digital signals proportional to specific analytes. Examples include immunosensors and enzyme-based biosensors, applied in various fields such as medicine, environmental monitoring, and food industry. The journal also focuses on molecular and supramolecular structures for enhancing device performance.