Monte Carlo-based assessment of solid phantom equivalence to water in radiation therapy quality assurance

IF 3.5 3区 物理与天体物理 Q3 CHEMISTRY, PHYSICAL
Radiation Physics and Chemistry Pub Date : 2026-06-01 Epub Date: 2026-02-06 DOI:10.1016/j.radphyschem.2026.113693
A. Khallouqi , H. Sekkat , O. Elmouden , N. Ghosne , I. Lagrini , A. Halimi , O. El rhazouani
{"title":"Monte Carlo-based assessment of solid phantom equivalence to water in radiation therapy quality assurance","authors":"A. Khallouqi ,&nbsp;H. Sekkat ,&nbsp;O. Elmouden ,&nbsp;N. Ghosne ,&nbsp;I. Lagrini ,&nbsp;A. Halimi ,&nbsp;O. El rhazouani","doi":"10.1016/j.radphyschem.2026.113693","DOIUrl":null,"url":null,"abstract":"<div><div>Accurate dosimetry is crucial for optimizing radiotherapy outcomes, balancing tumor control with healthy tissue sparing. Water phantoms represent the gold standard due to their tissue-equivalent properties, yet practical limitations such as setup complexity and portability drive the need for solid alternatives. This study employs Monte Carlo simulations using the GATE platform to comprehensively evaluate the dosimetric equivalence of common solid phantoms; RW3, Nylon, PMMA, Polyester, Polyethylene, Polystyrene, Original Plastic Water, and Virtual Water; against water for a 6 MV flattened photon beam from a Varian TrueBeam linear accelerator. Dosimetric parameters, including percentage depth dose (PDD) curves, lateral dose profiles at depth of 10 cm, and 3D volumetric dose distributions, were assessed under identical beam configurations (10 × 10 cm<sup>2</sup> field size, 100 cm SSD). Validation against experimental data acquired using a PTW Semiflex ionization chamber (0.125 cm<sup>3</sup>) in a motorized water phantom confirmed simulation fidelity, with gamma pass rates exceeding 99% (2%/2 mm criterion). Results ranked RW3 as the superior water substitute (mean PDD deviation: 0.65%; lateral: 4.68%; RMSE: 5.62%), followed by Plastic and Virtual phantoms, while Nylon, and Polyester exhibited unacceptable deviations (&gt;10%). Polyethylene showed anomalous positive bias (+3.98% PDD). These findings, benchmarked against IAEA and AAPM tolerance criteria (±2% for reference dosimetry, ±3% for routine QA), highlight material-specific radiological properties influencing photon interactions, underscoring RW3's utility for clinical quality assurance while identifying materials requiring correction factors (Polystyrene, Polyethylene) or unsuitable for clinical use without extensive adjustments (Nylon, Polyester exceeding 10% deviation).</div></div>","PeriodicalId":20861,"journal":{"name":"Radiation Physics and Chemistry","volume":"243 ","pages":"Article 113693"},"PeriodicalIF":3.5000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Physics and Chemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969806X26001039","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Accurate dosimetry is crucial for optimizing radiotherapy outcomes, balancing tumor control with healthy tissue sparing. Water phantoms represent the gold standard due to their tissue-equivalent properties, yet practical limitations such as setup complexity and portability drive the need for solid alternatives. This study employs Monte Carlo simulations using the GATE platform to comprehensively evaluate the dosimetric equivalence of common solid phantoms; RW3, Nylon, PMMA, Polyester, Polyethylene, Polystyrene, Original Plastic Water, and Virtual Water; against water for a 6 MV flattened photon beam from a Varian TrueBeam linear accelerator. Dosimetric parameters, including percentage depth dose (PDD) curves, lateral dose profiles at depth of 10 cm, and 3D volumetric dose distributions, were assessed under identical beam configurations (10 × 10 cm2 field size, 100 cm SSD). Validation against experimental data acquired using a PTW Semiflex ionization chamber (0.125 cm3) in a motorized water phantom confirmed simulation fidelity, with gamma pass rates exceeding 99% (2%/2 mm criterion). Results ranked RW3 as the superior water substitute (mean PDD deviation: 0.65%; lateral: 4.68%; RMSE: 5.62%), followed by Plastic and Virtual phantoms, while Nylon, and Polyester exhibited unacceptable deviations (>10%). Polyethylene showed anomalous positive bias (+3.98% PDD). These findings, benchmarked against IAEA and AAPM tolerance criteria (±2% for reference dosimetry, ±3% for routine QA), highlight material-specific radiological properties influencing photon interactions, underscoring RW3's utility for clinical quality assurance while identifying materials requiring correction factors (Polystyrene, Polyethylene) or unsuitable for clinical use without extensive adjustments (Nylon, Polyester exceeding 10% deviation).
基于蒙特卡罗的放射治疗质量保证中固体幻相与水等效性评估
准确的剂量测定对于优化放疗结果、平衡肿瘤控制与健康组织保留至关重要。由于其与组织相当的特性,水幻影代表了黄金标准,但实际限制,如设置复杂性和可移植性,推动了对固体替代品的需求。本研究利用GATE平台进行蒙特卡罗模拟,综合评价了常见固体幻影的剂量学等效性;RW3、尼龙、PMMA、聚酯、聚乙烯、聚苯乙烯、原塑料水、虚拟水;对来自瓦里安TrueBeam直线加速器的6 MV扁平光子束进行了实验。剂量学参数,包括百分比深度剂量(PDD)曲线、10 cm深度侧位剂量分布和三维体积剂量分布,在相同的光束配置(10 × 10 cm2场大小,100 cm SSD)下进行评估。利用电动水幻影中的PTW Semiflex电离室(0.125 cm3)获得的实验数据进行验证,证实了模拟的保真度,伽马通过率超过99% (2%/ 2mm标准)。结果显示,RW3是最佳的水替代品(平均PDD偏差:0.65%;横向:4.68%;RMSE: 5.62%),其次是塑料和虚拟幻影,而尼龙和聚酯的偏差为不可接受的(>10%)。聚乙烯显示异常正偏(+3.98% PDD)。这些发现以IAEA和AAPM公差标准为基准(参考剂量测定±2%,常规QA±3%),突出了影响光子相互作用的材料特异性放射学特性,强调了RW3在临床质量保证方面的实用性,同时确定了需要校正因子(聚苯乙烯、聚乙烯)或不适合临床使用的材料(尼龙、聚酯超过10%的偏差)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiation Physics and Chemistry
Radiation Physics and Chemistry 化学-核科学技术
CiteScore
5.60
自引率
17.20%
发文量
574
审稿时长
12 weeks
期刊介绍: Radiation Physics and Chemistry is a multidisciplinary journal that provides a medium for publication of substantial and original papers, reviews, and short communications which focus on research and developments involving ionizing radiation in radiation physics, radiation chemistry and radiation processing. The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. This could include papers that are very similar to previous publications, only with changed target substrates, employed materials, analyzed sites and experimental methods, report results without presenting new insights and/or hypothesis testing, or do not focus on the radiation effects.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书