A. Khallouqi , H. Sekkat , O. Elmouden , N. Ghosne , I. Lagrini , A. Halimi , O. El rhazouani
{"title":"Monte Carlo-based assessment of solid phantom equivalence to water in radiation therapy quality assurance","authors":"A. Khallouqi , H. Sekkat , O. Elmouden , N. Ghosne , I. Lagrini , A. Halimi , O. El rhazouani","doi":"10.1016/j.radphyschem.2026.113693","DOIUrl":null,"url":null,"abstract":"<div><div>Accurate dosimetry is crucial for optimizing radiotherapy outcomes, balancing tumor control with healthy tissue sparing. Water phantoms represent the gold standard due to their tissue-equivalent properties, yet practical limitations such as setup complexity and portability drive the need for solid alternatives. This study employs Monte Carlo simulations using the GATE platform to comprehensively evaluate the dosimetric equivalence of common solid phantoms; RW3, Nylon, PMMA, Polyester, Polyethylene, Polystyrene, Original Plastic Water, and Virtual Water; against water for a 6 MV flattened photon beam from a Varian TrueBeam linear accelerator. Dosimetric parameters, including percentage depth dose (PDD) curves, lateral dose profiles at depth of 10 cm, and 3D volumetric dose distributions, were assessed under identical beam configurations (10 × 10 cm<sup>2</sup> field size, 100 cm SSD). Validation against experimental data acquired using a PTW Semiflex ionization chamber (0.125 cm<sup>3</sup>) in a motorized water phantom confirmed simulation fidelity, with gamma pass rates exceeding 99% (2%/2 mm criterion). Results ranked RW3 as the superior water substitute (mean PDD deviation: 0.65%; lateral: 4.68%; RMSE: 5.62%), followed by Plastic and Virtual phantoms, while Nylon, and Polyester exhibited unacceptable deviations (>10%). Polyethylene showed anomalous positive bias (+3.98% PDD). These findings, benchmarked against IAEA and AAPM tolerance criteria (±2% for reference dosimetry, ±3% for routine QA), highlight material-specific radiological properties influencing photon interactions, underscoring RW3's utility for clinical quality assurance while identifying materials requiring correction factors (Polystyrene, Polyethylene) or unsuitable for clinical use without extensive adjustments (Nylon, Polyester exceeding 10% deviation).</div></div>","PeriodicalId":20861,"journal":{"name":"Radiation Physics and Chemistry","volume":"243 ","pages":"Article 113693"},"PeriodicalIF":3.5000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Physics and Chemistry","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0969806X26001039","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/6 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Accurate dosimetry is crucial for optimizing radiotherapy outcomes, balancing tumor control with healthy tissue sparing. Water phantoms represent the gold standard due to their tissue-equivalent properties, yet practical limitations such as setup complexity and portability drive the need for solid alternatives. This study employs Monte Carlo simulations using the GATE platform to comprehensively evaluate the dosimetric equivalence of common solid phantoms; RW3, Nylon, PMMA, Polyester, Polyethylene, Polystyrene, Original Plastic Water, and Virtual Water; against water for a 6 MV flattened photon beam from a Varian TrueBeam linear accelerator. Dosimetric parameters, including percentage depth dose (PDD) curves, lateral dose profiles at depth of 10 cm, and 3D volumetric dose distributions, were assessed under identical beam configurations (10 × 10 cm2 field size, 100 cm SSD). Validation against experimental data acquired using a PTW Semiflex ionization chamber (0.125 cm3) in a motorized water phantom confirmed simulation fidelity, with gamma pass rates exceeding 99% (2%/2 mm criterion). Results ranked RW3 as the superior water substitute (mean PDD deviation: 0.65%; lateral: 4.68%; RMSE: 5.62%), followed by Plastic and Virtual phantoms, while Nylon, and Polyester exhibited unacceptable deviations (>10%). Polyethylene showed anomalous positive bias (+3.98% PDD). These findings, benchmarked against IAEA and AAPM tolerance criteria (±2% for reference dosimetry, ±3% for routine QA), highlight material-specific radiological properties influencing photon interactions, underscoring RW3's utility for clinical quality assurance while identifying materials requiring correction factors (Polystyrene, Polyethylene) or unsuitable for clinical use without extensive adjustments (Nylon, Polyester exceeding 10% deviation).
期刊介绍:
Radiation Physics and Chemistry is a multidisciplinary journal that provides a medium for publication of substantial and original papers, reviews, and short communications which focus on research and developments involving ionizing radiation in radiation physics, radiation chemistry and radiation processing.
The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. This could include papers that are very similar to previous publications, only with changed target substrates, employed materials, analyzed sites and experimental methods, report results without presenting new insights and/or hypothesis testing, or do not focus on the radiation effects.