Pediatric autologous peripheral blood stem cell collection without heparin using a highly concentrated sodium citrate anticoagulant: A retrospective comparison with standard ACD-A.
{"title":"Pediatric autologous peripheral blood stem cell collection without heparin using a highly concentrated sodium citrate anticoagulant: A retrospective comparison with standard ACD-A.","authors":"Keiko Fujii, Wataru Kitamura, Kana Washio, Kazuhiro Ikeuchi, Joji Shimono, Hiroyuki Murakami, Fumio Otsuka, Yoshinobu Maeda, Nobuharu Fujii","doi":"10.1111/trf.70102","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Heparin combined with sodium citrate has been used in leukocytapheresis for pediatric patients. Since 2022, we have performed leukocytapheresis using a highly concentrated sodium citrate solution (HSC, 5.32%) instead of acid citrate dextrose solution A (ACD-A). We conducted this study to determine whether HSC use reduces run time and the total amount of anticoagulant solution in children.</p><p><strong>Study design and methods: </strong>We retrospectively analyzed data from consecutive autologous peripheral blood stem cell harvests (auto-PBSCHs) between June 2012 and May 2025, including patient characteristics, mobilization methods, protocol used, anticoagulant type, run time, total anticoagulant solution volume, and collection efficiency.</p><p><strong>Results: </strong>Auto-PBSCH was performed using the mononuclear cell collection (MNC) protocol in 28 procedures and the continuous MNC protocol in 20 procedures. ACD-A was used in 35 procedures and HSC in 13. The run time was significantly shorter (204 [range, 117-302] vs. 157 min [range, 103-227], p = .02) in the HSC group and also confirmed in multivariable regression analysis (coefficient, -55.6; 95% confidence interval, -106.2 to -5.04; p = .03). In a subgroup analysis of cMNC procedures, CD34<sup>+</sup> collection efficiency showed a strong negative correlation with the proportion of run time devoted to establishing the initial interface (r = -.73, p = .0003).</p><p><strong>Conclusion: </strong>Delays in establishing the initial interface can reduce the duration of the effective MNC collection phase and may negatively affect collection efficiency. Careful attention to the initial interface phase is therefore warranted when using HSC.</p>","PeriodicalId":23266,"journal":{"name":"Transfusion","volume":" ","pages":"677-688"},"PeriodicalIF":2.0000,"publicationDate":"2026-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13049261/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transfusion","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/trf.70102","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Heparin combined with sodium citrate has been used in leukocytapheresis for pediatric patients. Since 2022, we have performed leukocytapheresis using a highly concentrated sodium citrate solution (HSC, 5.32%) instead of acid citrate dextrose solution A (ACD-A). We conducted this study to determine whether HSC use reduces run time and the total amount of anticoagulant solution in children.
Study design and methods: We retrospectively analyzed data from consecutive autologous peripheral blood stem cell harvests (auto-PBSCHs) between June 2012 and May 2025, including patient characteristics, mobilization methods, protocol used, anticoagulant type, run time, total anticoagulant solution volume, and collection efficiency.
Results: Auto-PBSCH was performed using the mononuclear cell collection (MNC) protocol in 28 procedures and the continuous MNC protocol in 20 procedures. ACD-A was used in 35 procedures and HSC in 13. The run time was significantly shorter (204 [range, 117-302] vs. 157 min [range, 103-227], p = .02) in the HSC group and also confirmed in multivariable regression analysis (coefficient, -55.6; 95% confidence interval, -106.2 to -5.04; p = .03). In a subgroup analysis of cMNC procedures, CD34+ collection efficiency showed a strong negative correlation with the proportion of run time devoted to establishing the initial interface (r = -.73, p = .0003).
Conclusion: Delays in establishing the initial interface can reduce the duration of the effective MNC collection phase and may negatively affect collection efficiency. Careful attention to the initial interface phase is therefore warranted when using HSC.
期刊介绍:
TRANSFUSION is the foremost publication in the world for new information regarding transfusion medicine. Written by and for members of AABB and other health-care workers, TRANSFUSION reports on the latest technical advances, discusses opposing viewpoints regarding controversial issues, and presents key conference proceedings. In addition to blood banking and transfusion medicine topics, TRANSFUSION presents submissions concerning patient blood management, tissue transplantation and hematopoietic, cellular, and gene therapies.