Standardizing Stimulus Parameters for Noisy Galvanic Vestibular Stimulation.

IF 1.8 Q3 OTORHINOLARYNGOLOGY
Journal of Audiology and Otology Pub Date : 2026-01-01 Epub Date: 2026-01-20 DOI:10.7874/jao.2025.00514
Faith Whitebread, Choongheon Lee
{"title":"Standardizing Stimulus Parameters for Noisy Galvanic Vestibular Stimulation.","authors":"Faith Whitebread, Choongheon Lee","doi":"10.7874/jao.2025.00514","DOIUrl":null,"url":null,"abstract":"<p><p>Noisy galvanic vestibular stimulation (nGVS) delivers band-limited subsensory electrical noise at the mastoids to amplify vestibular signaling via stochastic resonance. This review synthesizes human studies involving healthy participants and proposes a practical stimulation protocol and reporting checklist to promote standardization of nGVS in vestibular research and clinical translation. Evidence supports the use of a bilateral bipolar mastoid montage; 1.75-10 cm2 electrodes; zero-mean Gaussian white noise with a 0-30 Hz passband (or 0-640 Hz when replicating prior work or testing cortical or perceptual hypotheses); participant-titrated subsensory intensities (typically 100-400 μA, with fixed protocols often 400-1,000 μA); and task-matched stimulation epochs of 10-30 seconds. Reports should specify the electrode polarity, passband and filter details, amplitude reference (peak, peak-to-peak, or root-mean-square), threshold procedures, and total stimulation dose. Under these conditions, nGVS has been shown to improve vestibulospinal outcomes (reduced postural sway and better gait stability), modulate vestibulo-ocular physiology, and lower vestibular motion detection thresholds. The effects scale with task difficulty and baseline vestibular function; tolerability was favorable at the subsensory level. Priorities for future research include head-to-head tests of montage and frequency, individualized dose-response and after-effect mapping, stratification by baseline vestibular status, and mechanistic biomarkers tied to behavior. Standardized parameters and reporting will enable robust meta-analyses and faster clinical translation.</p>","PeriodicalId":44886,"journal":{"name":"Journal of Audiology and Otology","volume":"30 1","pages":"13-22"},"PeriodicalIF":1.8000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12862178/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Audiology and Otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7874/jao.2025.00514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Noisy galvanic vestibular stimulation (nGVS) delivers band-limited subsensory electrical noise at the mastoids to amplify vestibular signaling via stochastic resonance. This review synthesizes human studies involving healthy participants and proposes a practical stimulation protocol and reporting checklist to promote standardization of nGVS in vestibular research and clinical translation. Evidence supports the use of a bilateral bipolar mastoid montage; 1.75-10 cm2 electrodes; zero-mean Gaussian white noise with a 0-30 Hz passband (or 0-640 Hz when replicating prior work or testing cortical or perceptual hypotheses); participant-titrated subsensory intensities (typically 100-400 μA, with fixed protocols often 400-1,000 μA); and task-matched stimulation epochs of 10-30 seconds. Reports should specify the electrode polarity, passband and filter details, amplitude reference (peak, peak-to-peak, or root-mean-square), threshold procedures, and total stimulation dose. Under these conditions, nGVS has been shown to improve vestibulospinal outcomes (reduced postural sway and better gait stability), modulate vestibulo-ocular physiology, and lower vestibular motion detection thresholds. The effects scale with task difficulty and baseline vestibular function; tolerability was favorable at the subsensory level. Priorities for future research include head-to-head tests of montage and frequency, individualized dose-response and after-effect mapping, stratification by baseline vestibular status, and mechanistic biomarkers tied to behavior. Standardized parameters and reporting will enable robust meta-analyses and faster clinical translation.

Abstract Image

Abstract Image

Abstract Image

噪声前庭电刺激参数标准化。
噪声前庭电刺激(nGVS)通过随机共振在乳突肌上传递带限制的亚感觉电噪声来放大前庭信号。本文综合了健康参与者的人体研究,提出了一种实用的刺激方案和报告清单,以促进前庭研究和临床翻译中nGVS的标准化。证据支持使用双侧乳突蒙太奇;1.75-10 cm2电极;0-30 Hz通带的零均值高斯白噪声(或在复制先前的工作或测试皮层或感知假设时为0-640 Hz);参与者滴定亚感觉强度(通常为100-400 μA,固定方案通常为400- 1000 μA);任务匹配刺激时间为10-30秒。报告应详细说明电极极性、通带和滤波器细节、幅度参考(峰、峰对峰或均方根)、阈值程序和总刺激剂量。在这些条件下,nGVS已被证明可以改善前庭脊髓预后(减少姿势摇摆和更好的步态稳定性),调节前庭眼生理,降低前庭运动检测阈值。任务难度和基线前庭功能的影响量表;亚感觉水平耐受性良好。未来研究的重点包括蒙太奇和频率的头对头测试,个体化剂量反应和后效映射,基线前庭状态分层,以及与行为相关的机械生物标志物。标准化的参数和报告将使强大的荟萃分析和更快的临床翻译成为可能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Audiology and Otology
Journal of Audiology and Otology OTORHINOLARYNGOLOGY-
CiteScore
1.90
自引率
9.10%
发文量
20
期刊介绍: Journal of Audiology and Otology (JAO) (formerly known as Korean Journal of Audiology) aims to publish the most advanced findings for all aspects of the auditory and vestibular system and diseases of the ear using state-of-the-art techniques and analyses. The journal covers recent trends related to the topics of audiology, otology, and neurotology conducted by professionals, with the goal of providing better possible treatment to people of all ages, from infants to the elderly, who suffer from auditory and/or vestibular disorders and thus, improving their quality of life. This journal encourages the submission of review papers about current professional issues, research papers presenting a scientific base and clinical application, and case papers with unique reports or clinical trials. We also invite letters to the editor and papers related to the manufacture and distribution of medical devices. This journal provides integrated views from otologists, audiologists, and other healthcare practitioners, offering readers high quality scientific and clinical information. This peer-reviewed and open access journal has been the official journal of the Korean Audiological Society since 1997 and of both the Korean Audiological Society and the Korean Otological Society since 2017. It is published in English four times a year in January, April, July, and October.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书