{"title":"Standardizing Stimulus Parameters for Noisy Galvanic Vestibular Stimulation.","authors":"Faith Whitebread, Choongheon Lee","doi":"10.7874/jao.2025.00514","DOIUrl":null,"url":null,"abstract":"<p><p>Noisy galvanic vestibular stimulation (nGVS) delivers band-limited subsensory electrical noise at the mastoids to amplify vestibular signaling via stochastic resonance. This review synthesizes human studies involving healthy participants and proposes a practical stimulation protocol and reporting checklist to promote standardization of nGVS in vestibular research and clinical translation. Evidence supports the use of a bilateral bipolar mastoid montage; 1.75-10 cm2 electrodes; zero-mean Gaussian white noise with a 0-30 Hz passband (or 0-640 Hz when replicating prior work or testing cortical or perceptual hypotheses); participant-titrated subsensory intensities (typically 100-400 μA, with fixed protocols often 400-1,000 μA); and task-matched stimulation epochs of 10-30 seconds. Reports should specify the electrode polarity, passband and filter details, amplitude reference (peak, peak-to-peak, or root-mean-square), threshold procedures, and total stimulation dose. Under these conditions, nGVS has been shown to improve vestibulospinal outcomes (reduced postural sway and better gait stability), modulate vestibulo-ocular physiology, and lower vestibular motion detection thresholds. The effects scale with task difficulty and baseline vestibular function; tolerability was favorable at the subsensory level. Priorities for future research include head-to-head tests of montage and frequency, individualized dose-response and after-effect mapping, stratification by baseline vestibular status, and mechanistic biomarkers tied to behavior. Standardized parameters and reporting will enable robust meta-analyses and faster clinical translation.</p>","PeriodicalId":44886,"journal":{"name":"Journal of Audiology and Otology","volume":"30 1","pages":"13-22"},"PeriodicalIF":1.8000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12862178/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Audiology and Otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7874/jao.2025.00514","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/20 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Noisy galvanic vestibular stimulation (nGVS) delivers band-limited subsensory electrical noise at the mastoids to amplify vestibular signaling via stochastic resonance. This review synthesizes human studies involving healthy participants and proposes a practical stimulation protocol and reporting checklist to promote standardization of nGVS in vestibular research and clinical translation. Evidence supports the use of a bilateral bipolar mastoid montage; 1.75-10 cm2 electrodes; zero-mean Gaussian white noise with a 0-30 Hz passband (or 0-640 Hz when replicating prior work or testing cortical or perceptual hypotheses); participant-titrated subsensory intensities (typically 100-400 μA, with fixed protocols often 400-1,000 μA); and task-matched stimulation epochs of 10-30 seconds. Reports should specify the electrode polarity, passband and filter details, amplitude reference (peak, peak-to-peak, or root-mean-square), threshold procedures, and total stimulation dose. Under these conditions, nGVS has been shown to improve vestibulospinal outcomes (reduced postural sway and better gait stability), modulate vestibulo-ocular physiology, and lower vestibular motion detection thresholds. The effects scale with task difficulty and baseline vestibular function; tolerability was favorable at the subsensory level. Priorities for future research include head-to-head tests of montage and frequency, individualized dose-response and after-effect mapping, stratification by baseline vestibular status, and mechanistic biomarkers tied to behavior. Standardized parameters and reporting will enable robust meta-analyses and faster clinical translation.
期刊介绍:
Journal of Audiology and Otology (JAO) (formerly known as Korean Journal of Audiology) aims to publish the most advanced findings for all aspects of the auditory and vestibular system and diseases of the ear using state-of-the-art techniques and analyses. The journal covers recent trends related to the topics of audiology, otology, and neurotology conducted by professionals, with the goal of providing better possible treatment to people of all ages, from infants to the elderly, who suffer from auditory and/or vestibular disorders and thus, improving their quality of life. This journal encourages the submission of review papers about current professional issues, research papers presenting a scientific base and clinical application, and case papers with unique reports or clinical trials. We also invite letters to the editor and papers related to the manufacture and distribution of medical devices. This journal provides integrated views from otologists, audiologists, and other healthcare practitioners, offering readers high quality scientific and clinical information. This peer-reviewed and open access journal has been the official journal of the Korean Audiological Society since 1997 and of both the Korean Audiological Society and the Korean Otological Society since 2017. It is published in English four times a year in January, April, July, and October.