Seismic vulnerability assessment and performance improvement of the historical Mehmet Arif Pasha Mansion using optimized tuned mass dampers

IF 7.6 1区 工程技术 Q1 ENGINEERING, CIVIL
Engineering Structures Pub Date : 2026-04-15 Epub Date: 2026-01-29 DOI:10.1016/j.engstruct.2026.122247
Oguz Uzdil , Sinan Melih Nigdeli , Turgay Cosgun , Gebrail Bekdaş
{"title":"Seismic vulnerability assessment and performance improvement of the historical Mehmet Arif Pasha Mansion using optimized tuned mass dampers","authors":"Oguz Uzdil ,&nbsp;Sinan Melih Nigdeli ,&nbsp;Turgay Cosgun ,&nbsp;Gebrail Bekdaş","doi":"10.1016/j.engstruct.2026.122247","DOIUrl":null,"url":null,"abstract":"<div><div>This study examines the effectiveness of tuned mass dampers (TMDs) as a non-intrusive seismic mitigation strategy for a historical masonry structure within a performance-based assessment framework. The novelty of the study lies in the systematic, code-consistent evaluation of both classical Den Hartog–tuned and optimally parameterized TMDs for masonry structures under multiple seismic hazard levels (DD-1, DD-2, and DD-3), with explicit consideration of mass-ratio sensitivity. Linear time-history and nonlinear analyses are performed for TMD mass ratios of 3 %, 5 %, 10 %, and 20 %. The results indicate consistent reductions in relative floor displacement rates and collapse indicators across all earthquake levels. At the DD-3 earthquake level, collapse rate reductions of up to 50 % are observed for mass ratios between 3 % and 10 %, increasing to approximately 60–68 % for a 20 % mass ratio. Time-history analyses show that the most efficient displacement reduction occurs at a 5 % mass ratio, with decreases of 0.33 % in the x-direction and 1.20 % in the y-direction, while higher mass ratios provide diminishing additional benefits. Nonlinear analyses further confirm reductions in relative floor displacement rates of 0.20–0.34 %, particularly on the second normal floor. The findings demonstrate that performance-based optimization enables an effective and balanced application of passive vibration control for historical masonry structures.</div></div>","PeriodicalId":11763,"journal":{"name":"Engineering Structures","volume":"353 ","pages":"Article 122247"},"PeriodicalIF":7.6000,"publicationDate":"2026-04-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Structures","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0141029626001604","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

This study examines the effectiveness of tuned mass dampers (TMDs) as a non-intrusive seismic mitigation strategy for a historical masonry structure within a performance-based assessment framework. The novelty of the study lies in the systematic, code-consistent evaluation of both classical Den Hartog–tuned and optimally parameterized TMDs for masonry structures under multiple seismic hazard levels (DD-1, DD-2, and DD-3), with explicit consideration of mass-ratio sensitivity. Linear time-history and nonlinear analyses are performed for TMD mass ratios of 3 %, 5 %, 10 %, and 20 %. The results indicate consistent reductions in relative floor displacement rates and collapse indicators across all earthquake levels. At the DD-3 earthquake level, collapse rate reductions of up to 50 % are observed for mass ratios between 3 % and 10 %, increasing to approximately 60–68 % for a 20 % mass ratio. Time-history analyses show that the most efficient displacement reduction occurs at a 5 % mass ratio, with decreases of 0.33 % in the x-direction and 1.20 % in the y-direction, while higher mass ratios provide diminishing additional benefits. Nonlinear analyses further confirm reductions in relative floor displacement rates of 0.20–0.34 %, particularly on the second normal floor. The findings demonstrate that performance-based optimization enables an effective and balanced application of passive vibration control for historical masonry structures.
历史建筑穆罕默德·阿里夫·帕夏大厦的地震易损性评估及性能改进
本研究在基于性能的评估框架内考察了调谐质量阻尼器(TMDs)作为历史砌体结构非侵入式地震缓解策略的有效性。本研究的新颖之处在于,在明确考虑质量比敏感性的情况下,对多个地震危险级别(DD-1、DD-2和DD-3)下砌体结构的经典Den hartog调优和最佳参数化tmd进行了系统的、符合规范的评估。对TMD质量比分别为3 %、5 %、10 %和20 %进行了线性时程和非线性分析。结果表明,在所有地震级别上,相对楼板位移率和倒塌指标都有一致的降低。在DD-3级地震级别,当质量比在3 %和10 %之间时,倒塌率降低高达50 %,当质量比在20 %时,倒塌率增加到约60-68 %。时程分析表明,最有效的减排量发生在5 %的质量比下,在x方向上减少0.33 %,在y方向上减少1.20 %,而更高的质量比带来的额外效益逐渐减少。非线性分析进一步证实,相对楼层位移率降低了0.20-0.34 %,特别是在第二层正常楼层。研究结果表明,基于性能的优化可以有效和平衡地应用于历史砌体结构的被动振动控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Engineering Structures
Engineering Structures 工程技术-工程:土木
CiteScore
10.20
自引率
14.50%
发文量
1385
审稿时长
67 days
期刊介绍: Engineering Structures provides a forum for a broad blend of scientific and technical papers to reflect the evolving needs of the structural engineering and structural mechanics communities. Particularly welcome are contributions dealing with applications of structural engineering and mechanics principles in all areas of technology. The journal aspires to a broad and integrated coverage of the effects of dynamic loadings and of the modelling techniques whereby the structural response to these loadings may be computed. The scope of Engineering Structures encompasses, but is not restricted to, the following areas: infrastructure engineering; earthquake engineering; structure-fluid-soil interaction; wind engineering; fire engineering; blast engineering; structural reliability/stability; life assessment/integrity; structural health monitoring; multi-hazard engineering; structural dynamics; optimization; expert systems; experimental modelling; performance-based design; multiscale analysis; value engineering. Topics of interest include: tall buildings; innovative structures; environmentally responsive structures; bridges; stadiums; commercial and public buildings; transmission towers; television and telecommunication masts; foldable structures; cooling towers; plates and shells; suspension structures; protective structures; smart structures; nuclear reactors; dams; pressure vessels; pipelines; tunnels. Engineering Structures also publishes review articles, short communications and discussions, book reviews, and a diary on international events related to any aspect of structural engineering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书