Validation of the automated oscillometric upper-arm cuff home blood pressure monitor Prolife PA5 Comfort AF (BP 136A) in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.

IF 1 4区 医学 Q4 PERIPHERAL VASCULAR DISEASE
Ariadni Menti, Vasileios Ntousopoulos, Petroula Lempidaki, Konstantina-Rozalia Bakalakou, Dimitrios Mariglis, Aikaterini Komnianou, Evangelia Ntaskagianni, Anastasios Kollias, George S Stergiou
{"title":"Validation of the automated oscillometric upper-arm cuff home blood pressure monitor Prolife PA5 Comfort AF (BP 136A) in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard.","authors":"Ariadni Menti, Vasileios Ntousopoulos, Petroula Lempidaki, Konstantina-Rozalia Bakalakou, Dimitrios Mariglis, Aikaterini Komnianou, Evangelia Ntaskagianni, Anastasios Kollias, George S Stergiou","doi":"10.1097/MBP.0000000000000793","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the accuracy of the automated oscillometric upper-arm cuff blood pressure (BP) measuring device Prolife PA5 Comfort AF (BP 136A) for home use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2 : 2018) and its amendments (1 : 2020 and 2 : 2024). The requirements of the Universal Standardand its amendments for a validation study in a general population using the same arm sequential measurement method were applied. Participants were recruited to fulfill the age, sex, BP level, arm circumference, and cuff size distribution criteria. The test device measures BP during inflation and uses a wide-range cuff for arm circumference 22-42 cm. One-hundred-twenty-eight individuals were recruited and 85 were analyzed [mean age: 54.9 ± 15.0 (SD) years, 36 (42%) men, arm circumference: 31.7 ± 5.4 cm, range: 22.5-41.9 cm). For validation Criterion 1, the mean difference ± SD between the test device and reference BP readings ( N  = 255) was -2.1 ± 7.5/-0.3 ± 5.3 mmHg (systolic/diastolic; threshold: ≤5 ± 8 mmHg). For Criterion 2, the SD of the averaged BP differences between the test device and reference BP per individual ( N  = 85) were 6.44/5.07 mmHg (systolic/diastolic; threshold: ≤6.62/6.95 mmHg). The automated oscillometric home BP monitor Prolife PA5 Comfort AF (BP 136A) fulfills all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2 : 2018) and its amendments (1 : 2020 and 2 : 2024) for a general population and can be recommended for clinical use.</p>","PeriodicalId":8950,"journal":{"name":"Blood Pressure Monitoring","volume":" ","pages":"149-152"},"PeriodicalIF":1.0000,"publicationDate":"2026-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Pressure Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000793","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

This study evaluated the accuracy of the automated oscillometric upper-arm cuff blood pressure (BP) measuring device Prolife PA5 Comfort AF (BP 136A) for home use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2 : 2018) and its amendments (1 : 2020 and 2 : 2024). The requirements of the Universal Standardand its amendments for a validation study in a general population using the same arm sequential measurement method were applied. Participants were recruited to fulfill the age, sex, BP level, arm circumference, and cuff size distribution criteria. The test device measures BP during inflation and uses a wide-range cuff for arm circumference 22-42 cm. One-hundred-twenty-eight individuals were recruited and 85 were analyzed [mean age: 54.9 ± 15.0 (SD) years, 36 (42%) men, arm circumference: 31.7 ± 5.4 cm, range: 22.5-41.9 cm). For validation Criterion 1, the mean difference ± SD between the test device and reference BP readings ( N  = 255) was -2.1 ± 7.5/-0.3 ± 5.3 mmHg (systolic/diastolic; threshold: ≤5 ± 8 mmHg). For Criterion 2, the SD of the averaged BP differences between the test device and reference BP per individual ( N  = 85) were 6.44/5.07 mmHg (systolic/diastolic; threshold: ≤6.62/6.95 mmHg). The automated oscillometric home BP monitor Prolife PA5 Comfort AF (BP 136A) fulfills all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2 : 2018) and its amendments (1 : 2020 and 2 : 2024) for a general population and can be recommended for clinical use.

根据医疗器械进步协会/欧洲高血压学会/国际标准化组织通用标准,在普通人群中验证自动振荡上臂袖带家庭血压监测仪Prolife PA5 Comfort AF (BP 136A)。
本研究根据医疗器械进步协会/欧洲高血压学会/国际标准化组织(AAMI/ESH/ISO)通用标准(ISO 81060- 2:20 18)及其修订(1:20 20 0和2:20 24),评估了用于普通人群家庭使用的自动示波式上臂袖带血压(BP)测量装置Prolife PA5 Comfort AF (BP 136A)的准确性。应用通用标准及其修订的要求,在普通人群中使用相同的臂序贯测量方法进行验证研究。参与者被招募来满足年龄、性别、血压水平、臂围和袖带大小分布标准。该测试装置在充气过程中测量血压,并使用宽范围袖带测量臂围22-42厘米。纳入128例,分析85例[平均年龄:54.9±15.0 (SD)岁,男性36例(42%),臂围:31.7±5.4 cm,范围:22.5-41.9 cm]。对于验证标准1,测试装置与参考血压读数(N = 255)之间的平均差±SD为-2.1±7.5/-0.3±5.3 mmHg(收缩压/舒张压;阈值:≤5±8 mmHg)。对于标准2,试验装置与个体参考血压(N = 85)的平均血压差的标准差为6.44/5.07 mmHg(收缩压/舒张压;阈值:≤6.62/6.95 mmHg)。自动振荡式家庭血压监测仪Prolife PA5 Comfort AF (BP 136A)符合AAMI/ESH/ISO通用标准(ISO 81060- 2:20 18)及其修订版(1:20 20 0和2:20 24 0)的所有要求,可推荐用于临床使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Blood Pressure Monitoring
Blood Pressure Monitoring 医学-外周血管病
CiteScore
2.00
自引率
7.70%
发文量
110
审稿时长
>12 weeks
期刊介绍: Blood Pressure Monitoring is devoted to original research in blood pressure measurement and blood pressure variability. It includes device technology, analytical methodology of blood pressure over time and its variability, clinical trials - including, but not limited to, pharmacology - involving blood pressure monitoring, blood pressure reactivity, patient evaluation, and outcomes and effectiveness research. This innovative journal contains papers dealing with all aspects of manual, automated, and ambulatory monitoring. Basic and clinical science papers are considered although the emphasis is on clinical medicine. Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书